Gas phase structures of sodiated oligosaccharides by ion mobility ion chromatography methods

被引:87
|
作者
Lee, S [1 ]
Wyttenbach, T [1 ]
Bowers, MT [1 ]
机构
[1] Univ Calif Santa Barbara, Dept Chem, Santa Barbara, CA 93106 USA
关键词
MALDI; chromatography; ion mobility; oligosaccharides;
D O I
10.1016/S0168-1176(97)00105-5
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Matrix assisted laser desorption ionization (MALDI) was used to generate sodiated parent ions of a number of oligosaccharides, including three tetraoses and two hexaoses. No fragmentation was observed in any of the systems. Ion mobility studies yielded gas phase cross sections which could be compared with predictions made by molecular mechanics/molecular dynamics calculations. In all three tetraoses (cellotetraose, maltotetraose and isomaltotetraose) the Na+ ion coordinated with all four sugar moities forming very similar structures even though the neutral structures are very different. In the two hexaose systems (alpha-cyclodextrin and maltohexaose) again the Na+ ion coordinated with four sugars. Molecular dynamics studies indicated that at temperatures above 300 K the Na+ ion was mobile and sampled all six sugars of the hexaoses. This work is compared to other work in the literature, and differences are discussed. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:605 / 614
页数:10
相关论文
共 50 条
  • [31] Peppermint protocol: first results for gas chromatography-ion mobility spectrometry
    Ruszkiewicz, Dorota M.
    Myers, Renelle
    Henderson, Ben
    Yusof, Hazim
    Meister, Austin
    Moreno, Sergi
    Eddleston, Michael
    Darnley, Kareen
    Nailon, William H.
    McLaren, Duncan
    Lao, Yvonne E.
    Hovda, Knut Erik
    Lam, Stephen
    Cristescu, Simona M.
    Thomas, C. L. Paul
    JOURNAL OF BREATH RESEARCH, 2022, 16 (03)
  • [32] Design for Gas Chromatography-Corona Discharge-Ion Mobility Spectrometry
    Jafari, Mohammad T.
    Saraji, Mohammad
    Sherafatmand, Hossein
    ANALYTICAL CHEMISTRY, 2012, 84 (22) : 10077 - 10084
  • [33] Differentiation of Goat Meat Freshness Using Gas Chromatography with Ion Mobility Spectrometry
    He, Shan
    Zhang, Bin
    Dong, Xuan
    Wei, Yuqing
    Li, Hongtu
    Tang, Bo
    MOLECULES, 2023, 28 (09):
  • [34] Gas chromatography-ion mobility spectrometry for the detection of human disease: a review
    Gao, Li
    Yang, Ruiwen
    Zhang, Jizhou
    Sheng, Miaomiao
    Sun, Yun
    Han, Bing
    Kai, Guoyin
    ANALYTICAL METHODS, 2024, 16 (43) : 7275 - 7293
  • [35] TUNABLE SELECTIVE DETECTION FOR CAPILLARY GAS-CHROMATOGRAPHY BY ION MOBILITY MONITORING
    BAIM, MA
    HILL, HH
    ANALYTICAL CHEMISTRY, 1982, 54 (01) : 38 - 43
  • [36] Gas-phase H/D exchange of sodiated glycine oligomers with ND3:: Exchange kinetics do not reflect parent ion structures
    Cox, HA
    Julian, RR
    Lee, SW
    Beauchamp, JL
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (20) : 6485 - 6490
  • [37] Development of Analytical Methods for the Air Pollutants in Flue Gas by Ion Chromatography
    Nonomura, Makoto
    BUNSEKI KAGAKU, 2016, 65 (11) : 625 - 635
  • [38] Comment on "Gas-Phase Chiral Separations by Ion Mobility Spectrometry"
    Hill, Herbert H., Jr.
    ANALYTICAL CHEMISTRY, 2022, 94 (06) : 3020 - 3021
  • [39] Gas-phase separation using a trapped ion mobility spectrometer
    Fernandez-Lima, Francisco
    Kaplan, Desmond A.
    Suetering, J.
    Park, Melvin A.
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2011, 14 (2-3) : 93 - 98
  • [40] Cryogenic Ion Mobility-Mass Spectrometry: Tracking Ion Structure from Solution to the Gas Phase
    Servage, Kelly A.
    Silveira, Joshua A.
    Fort, Kyle L.
    Russell, David H.
    ACCOUNTS OF CHEMICAL RESEARCH, 2016, 49 (07) : 1421 - 1428