On the optical alignment of the PLATO cameras

被引:0
|
作者
Royer, P. [1 ]
Clermont, L. [2 ]
Pertenais, M. [4 ]
Baeke, A. [2 ]
Huygen, R. [1 ]
De Ridder, J. [1 ]
Regibo, S. [1 ]
Dami, M. [6 ]
Vandenbussche, B. [1 ]
Balado Margeli, A. Belen [7 ]
Farinato, J. [3 ]
Greggio, D. [3 ]
Levillain, Y. [5 ]
Magrin, D. [3 ]
Marafatto, L. [3 ]
Pajas, M. [7 ]
Ramos Zapata, G. [7 ]
Valverde Guijarro, A. L. [7 ]
Viotto, V. [3 ]
机构
[1] Katholieke Univ Leuven, Inst Astron, Celestijnenlaan 200D Bus 2401, B-3001 Leuven, Belgium
[2] STAR Inst, Ctr Spatial Liege, Ave Preaily, B-4031 Angleur, Belgium
[3] INAF, Vicolo Osservatorio 5, I-35122 Padua, Italy
[4] DLR, Rutherfordstr 2, D-12489 Berlin, Germany
[5] ESA ESTEC, Postbus 299, NL-2200 AG Noordwijk, Netherlands
[6] Leonardo Co, Via Officine Galileo, Campi Bisenzio, Italy
[7] INTA, Carretera Ajalvir,Km 4, Torrejen De Ardoz 28850, Spain
来源
SPACE TELESCOPES AND INSTRUMENTATION 2020: OPTICAL, INFRARED, AND MILLIMETER WAVE | 2021年 / 11443卷
关键词
PLATO; AIT; AIV; optical alignment; spacecraft integration;
D O I
10.1117/12.2560690
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
PLATO is an exoplanet hunting mission from the European Space Agency. It is a medium-class mission, with a launch foreseen in 2026. Its prime objective is to uncover Earth-sized planets residing in the habitable zone of their host star. The payload consists of 26 cameras with a very wide field-of-view. While the operational temperature of the cameras will be -80 degrees C, the focal plane of each camera will be integrated with its telescope assembly (bearing the optics) at room temperature. The degradation of the optical quality at ambient, combined with the detector dark current and with the very high accuracy required from the alignment process bring a number of interesting challenges. In the present article, we review the alignment concept, present optical simulations of the measurements at ambient along with their analysis, and present an error budget for the optical measurements. The derivation of this error budget is easily applicable to all optical measurements to be performed during the alignment, i.e. the definition of the best image plane at the operational temperature and the optical alignment itself, at room temperature.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Transition edge cameras for fast optical spectrophotometry
    Romani, Roger W.
    Bay, Thomas J.
    Burney, Jennifer
    Cabrera, Blas
    HIGH TIME RESOLUTION ASTROPHYSICS, 2008, 351 : 311 - +
  • [42] Drone cameras: A unique approach to optical imaging
    Sniderman, Debbie, 1600, Hearst Business Communications (59):
  • [43] An optical fiber cable system for HDTV cameras
    Narimatsu, Takashi
    Sekiguchi, Tatsuo
    Sekino, Hiroyuki
    Furukawa Review, 2004, (25): : 24 - 27
  • [44] OPTICAL SYSTEMS FOR PLUMBICON COLOR BROADCAST CAMERAS
    VANDOORN, AG
    DELANG, H
    BOUWHUIS, G
    JOURNAL OF THE SOCIETY OF MOTION PICTURE TELEVISION ENGINEERS, 1966, 75 (10): : 1002 - &
  • [45] OPTICAL PROPERTY OF ELECTROMAGNETICALLY FOCUSED ELECTRONIC CAMERAS
    PICAT, JP
    ASTRONOMY & ASTROPHYSICS, 1971, 11 (02) : 257 - +
  • [46] Technological section: Optical imaging and cameras - Editorial
    Wickham, JEA
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 1996, 5 (05): : 409 - 409
  • [47] Reliable and repeatable characterization of optical streak cameras
    Charest, Michael R., Jr.
    Torres, Peter, III
    Silbernagel, Christopher T.
    Kalantar, Daniel H.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (10):
  • [48] Optical design of Cranz-Schardin cameras
    Lu, FK
    Liu, XJ
    OPTICAL ENGINEERING, 1997, 36 (07) : 1935 - 1941
  • [49] Upgrading optical information of rotating mirror cameras
    Li, Jingzhen
    Sun, Fengshan
    Huang, Hongbin
    Gong, Xiangdong
    Chen, Hongyi
    Lu, Xiaowei
    Cai, Yi
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11):
  • [50] Digital cameras: optical footprints in a performance metric
    Baker, Lionel
    OPTICAL FABRICATION, TESTING, AND METROLOGY III, 2008, 7102