Monitoring of high-intensity focused ultrasound lesion formation using decorrelation between high-speed ultrasonic images by parallel beamforming

被引:27
|
作者
Sasaki, Shoya [1 ]
Takagi, Ryo [1 ]
Matsuura, Keiko [1 ]
Yoshizawa, Shin [2 ]
Umemura, Shin-ichiro [1 ]
机构
[1] Tohoku Univ, Grad Sch Biomed Engn, Sendai, Miyagi 9808579, Japan
[2] Tohoku Univ, Grad Sch Engn, Sendai, Miyagi 9808579, Japan
关键词
CAVITATION; SURGERY; THERAPY; BEAM;
D O I
10.7567/JJAP.53.07KF10
中图分类号
O59 [应用物理学];
学科分类号
摘要
High-intensity focused ultrasound (HIFU) is a type of therapeutic treatment in which ultrasound is focused to a target tissue such as cancer to be thermally coagulated. To enhance the safety and accuracy of HIFU treatment, a noninvasive method of monitoring the thermal lesion formation is important. A potential method for this purpose is ultrasound imaging. In this study, high-speed imaging by parallel beamforming was performed using ultrasound RF signals acquired during HIFU exposure, and the distribution of the cross-correlation coefficient between RF frames was calculated to estimate the tissue coagulation. Using high-speed imaging, HIFU can be irradiated quasi-continuously. The result shows that the decorrelation was observed at and around the focal spot of HIFU exposure. The decorrelation was induced by the change in RF signals owing to tissue coagulation, which was confirmed by the fact that the emergence and increase in the number of decorrelated pixels at and around the focal spot corresponded to the start and progress of tissue coagulation. (C) 2014 The Japan Society of Applied Physics
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Impact of cavitation on lesion formation induced by high intensity focused ultrasound
    范鹏飞
    于洁
    杨鑫
    屠娟
    郭霞生
    黄品同
    章东
    Chinese Physics B, 2017, 26 (05) : 239 - 246
  • [32] Quantitative MR temperature monitoring of high-intensity focused ultrasound therapy
    Bohris, C
    Schreiber, WG
    Jenne, J
    Simiantonakis, I
    Rastert, R
    Zabel, HJ
    Huber, P
    Bader, R
    Brix, G
    MAGNETIC RESONANCE IMAGING, 1999, 17 (04) : 603 - 610
  • [33] PRODUCTION OF CORNEAL LESIONS USING HIGH-INTENSITY FOCUSED ULTRASOUND
    RUTZEN, AR
    ROBERTS, CW
    DRILLER, J
    GOMEZ, D
    LUCAS, BC
    LIZZI, FL
    COLEMAN, DJ
    CORNEA, 1990, 9 (04) : 324 - 330
  • [34] Hyperecho in ultrasound images during high-intensity focused ultrasound ablation for hepatocellular carcinomas
    Fukuda, Hiroyuki
    Numata, Kazushi
    Nozaki, Akito
    Kondo, Masaaki
    Morimoto, Manabu
    Tanaka, Katsuaki
    Ito, Ryu
    Ohto, Masao
    Ishibashi, Yoshiharu
    Oshima, Noriyoshi
    Ito, Ayao
    Zhu, Hui
    Wang, Zhi-Biao
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (03) : E571 - E575
  • [35] Influence of ablated tissue on the formation of high-intensity focused ultrasound lesions
    Chen, LL
    terHaar, G
    Hill, CR
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (06): : 921 - 931
  • [36] Monitoring formation of high intensity focused ultrasound (HIFU) induced lesions using backscattered ultrasound
    Anand, A
    Kaczkowski, PJ
    ACOUSTICS RESEARCH LETTERS ONLINE-ARLO, 2004, 5 (03): : 88 - 94
  • [37] Characterization of lesion formation and bubble activities during high-intensity focused ultrasound ablation using temperature-derived parameters
    Hsiao, Yi-Sing
    Kumon, Ronald E.
    Deng, Cheri X.
    INFRARED PHYSICS & TECHNOLOGY, 2013, 60 : 108 - 117
  • [38] Basic study on ultrasonic monitoring using 1.5-dimensional ultrasound phased array for ultrasound-guided high-intensity focused ultrasound treatment
    Takagi, Ryo
    Iwasaki, Ryosuke
    Tomiyasu, Kentaro
    Yoshizawa, Shin
    Umemura, Shin-ichiro
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2017, 56 (07)
  • [39] The feasibility of a noise elimination method using continuous wave response of therapeutic ultrasound signals for ultrasonic monitoring of high-intensity focused ultrasound treatment
    Takagi, Ryo
    Washio, Toshikatsu
    Koseki, Yoshihiko
    JOURNAL OF MEDICAL ULTRASONICS, 2021, 48 (02) : 123 - 135
  • [40] The feasibility of a noise elimination method using continuous wave response of therapeutic ultrasound signals for ultrasonic monitoring of high-intensity focused ultrasound treatment
    Ryo Takagi
    Toshikatsu Washio
    Yoshihiko Koseki
    Journal of Medical Ultrasonics, 2021, 48 : 123 - 135