Analysis of depth-sectioning STEM for thick samples and 3D imaging

被引:33
|
作者
Bosch, Eric G. T. [1 ]
Lazic, Ivan [1 ]
机构
[1] Thermo Fisher Sci, Achtseweg,Noord 5, NL-5651 GG Eindhoven, Noord Brabant, Netherlands
关键词
STEM; Depth sectioning STEM; Thick samples; 3D imaging; iDPC-STEM; TRANSMISSION ELECTRON-MICROSCOPY; S-STATE MODEL; TOMOGRAPHY; RESOLUTION; CONTRAST; ATOMS; RECONSTRUCTION; PROSPECTS; CRYSTALS;
D O I
10.1016/j.ultramic.2019.112831
中图分类号
TH742 [显微镜];
学科分类号
摘要
We derive a model that describes 3D volume imaging in depth-sectioning STEM that is valid for all STEM techniques under three well-defined conditions: linearity, undisturbed probe and elastic scattering. The resulting undisturbed probe model generalizes the widely used idea that the undisturbed probe intensity in three dimensions can be used as the point spread function for depth-sectioning ADF-STEM to all STEM techniques including (A)BF- and iDPC-STEM. The model provides closed expressions for depth-sectioning STEM, which follow directly from the 2D expressions for thin samples, and thereby enables analysis of the 3D resolution. Using the model we explore the consequences of the resulting 3D contrast transfer function (CTF) for the z-resolution at different length scales and illustrate this with experiments. We investigate the validity and limitations of the model using multi-slice simulations showing that it is valid and quantitatively accurate for relatively thick amorphous samples but not for crystalline samples in zone-axis due to channeling. We compare depth-sectioning in iDPC and ADF-STEM and show that iDPC-STEM can extract information from deeper into the sample, all the way fill the bottom of the sample, thereby effectively allowing a thickness measurement. Also the difference in optimal focus conditions between iDPC- and ADF-STEM is explained. Finally, we propose practical criteria for deciding whether a sample is thin or thick.
引用
收藏
页数:22
相关论文
共 50 条
  • [41] Imaging - 3D camera has no lens, great depth of field
    Radov, D
    SCIENCE, 1999, 284 (5423) : 2066 - 2067
  • [42] Orthoseopic, long-focal-depth 3D integral imaging
    Martinez-Corral, Manuel
    Martinez-Cuenca, Raul
    Saavedra, Genaro
    Javidi, Bahrain
    UNMANNED/UNATTENDED SENSORS AND SENSOR NETWORKS III, 2006, 6394
  • [43] 3D Reconstruction of Scoliotic Spines from Stereoradiography and Depth Imaging
    Groisser, Benjamin
    Kimmel, Ron
    Feldman, Guy
    Rozen, Nimrod
    Wolf, Alon
    ANNALS OF BIOMEDICAL ENGINEERING, 2018, 46 (08) : 1206 - 1215
  • [44] Learned Depth Estimation of 3D Imaging Radar for Indoor Mapping
    Xu, Ruoyang
    Dong, Wei
    Sharma, Akash
    Kaess, Michael
    2022 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS), 2022, : 13260 - 13267
  • [45] 3D Strain Measurement of Heterostructures Using the Scanning Transmission Electron Microscopy Moire Depth Sectioning Method
    Wen, Huihui
    Zhang, Hongye
    Peng, Runlai
    Liu, Chao
    Liu, Shuman
    Liu, Fengqi
    Xie, Huimin
    Liu, Zhanwei
    SMALL METHODS, 2023, 7 (09)
  • [46] Analysis Of Multiphoton Imaging Of Thick Biological Scattering Samples
    Cella, Francesca
    Lavagnino, Zeno
    Diaspro, Alberto
    BIOPHYSICAL JOURNAL, 2009, 96 (03) : 296A - 296A
  • [47] Authentication of two samples of ancient Chinese coins with component element depth analysis by confocal 3D XRF
    Zhou, Peng
    Liu, Zhiguo
    Lin, Xiaoyan
    Liu, Xin
    Ye, Lei
    Wang, Xingyi
    Pan, Kai
    Li, Yude
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2018, 423 : 37 - 41
  • [48] Improved Imaging, 3D Reconstruction and Homology Modeling of Tarantula Thick Filaments
    Yang, Shixin
    Zhao, Fa-Qing
    Sulbaran, Guidenn
    Woodhead, John L.
    Alamo, Lorenzo
    Pinto, Antonio
    Padron, Raul
    Craig, Roger
    BIOPHYSICAL JOURNAL, 2015, 108 (02) : 589A - 589A
  • [49] 3D crystallographic and morphological analysis of coarse martensite: Combining EBSD and serial sectioning
    Rowenhorst, D. J.
    Gupta, A.
    Feng, C. R.
    Spanos, G.
    SCRIPTA MATERIALIA, 2006, 55 (01) : 11 - 16
  • [50] 3D imaging for bite mark analysis
    Evans, S. T.
    Jones, C.
    Plassmann, P.
    IMAGING SCIENCE JOURNAL, 2013, 61 (04): : 351 - 360