QTR-FRET: Efficient background reduction technology in time-resolved forster resonance energy transfer assays

被引:4
|
作者
Syrjanpaa, Markku [1 ,4 ]
Vuorinen, Emmiliisa [2 ]
Kulmala, Sakari [3 ]
Wang, Qi [1 ]
Harma, Harri [2 ]
Kopra, Kari [2 ]
机构
[1] Univ Turku, Dept Cell Biol & Anat, Biophys Lab, Inst Biomed, Tykistokatu 6A, FI-20520 Turku, Finland
[2] Univ Turku, Dept Chem, Mat Chem & Chem Anal, Vatselankatu 2, FI-20500 Turku, Finland
[3] Aalto Univ, Dept Chem, Analyt Chem Lab, POB 16100, FI-00076 Aalto, Finland
[4] Abacus Diagnost Ltd, Tykistokatu 4D, FI-20520 Turku, Finland
基金
芬兰科学院;
关键词
Lanthanide chelate; Quenching resonance energy transfer (QRET); Streptavidin; Time-resolved forster resonance energy transfer (TR-FRET); KRAS; CONFORMATIONAL-CHANGES; BIOTIN; LABEL; STREPTAVIDIN; LUMINESCENCE; QRET;
D O I
10.1016/j.aca.2019.09.045
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel homogeneous assay system QTR-FRET (Quencher modulated Time-Resolved Forster Resonance Energy Transfer) combining quenching resonance energy transfer (QRET) and time-resolved Forster resonance energy transfer (TR-FRET) was developed to reduce background signal in the conventional energy transfer applications. The TR-FRET functionality is often limited by the lanthanide donor background signal leading to the use of low donor concentration. QTR-FRET reduces this background by introducing soluble quencher molecule, and in this work the concept functionality was proven and compared to previously introduced QRET and TR-FRET technologies. Comparison was performed with three different Eu3+-chelates exhibiting different luminescent lifetime and stability. The side-by-side comparison of the three signaling systems and Eu3+ -chelates was demonstrated in a model assay with Eu3+-chelate conjugated biotin and streptavidin (SA) or Cy5-SA conjugate. Comparison of the methodologies showed increased signal-to-background ratios when comparing QTR-FRET to TR-FRET, especially at high Eu3+ -biotin concentrations. Quenching the non-bound Eu3+-biotin improved the assay performance, which suggests that an improved assay performance can be attained with the QTR-FRET method. QTR-FRET is expected to be especially useful for Eu3+-labeled ligands with low affinity or assays requiring high Eu3+-ligand concentration. The QTR-FRET indicated potential for multi-analyte approaches separately utilizing the direct QRET-type Eu3+-chelate signal and energy transfer signal readout in a single- well. This potential was hypothesized with Avi-KRAS nucleotide exchange assay as a second biologically relevant model system. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:93 / 101
页数:9
相关论文
共 50 条
  • [1] Time-Resolved Fluorescence Resonance Energy Transfer [TR-FRET] Assays for Biochemical Processes
    Ergin, Ekin
    Dogan, Arin
    Parmaksiz, Mahmut
    Elcin, Ayse E.
    Elcin, Yasar M.
    CURRENT PHARMACEUTICAL BIOTECHNOLOGY, 2016, 17 (14) : 1222 - 1230
  • [2] Recommendations for the reduction of compound artifacts in time-resolved fluorescence resonance energy transfer assays
    Imbert, Pierre-Eloi
    Unterreiner, Vincent
    Siebert, Daniela
    Gubler, Hanspeter
    Parker, Christian
    Gabriel, Daniela
    ASSAY AND DRUG DEVELOPMENT TECHNOLOGIES, 2007, 5 (03) : 363 - 372
  • [3] The fluorescence resonance energy transfer (FRET) gate: A time-resolved study
    Xu, QH
    Wang, S
    Korystov, D
    Mikhailovsky, A
    Bazan, GC
    Moses, D
    Heeger, AJ
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2005, 102 (03) : 530 - 535
  • [4] Time-resolved Forster Resonance Energy Transfer Assays for Measurement of Endogenous Phosphorylated STAT Proteins in Human Cells
    Padros, Jaime
    Chatel, Genevieve
    Caron, Mireille
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2021, (175):
  • [5] Adaptive optics for a time-resolved Forster resonance energy transfer (FRET) and fluorescence lifetime imaging microscopy (FLIM) in vivo
    Coelho, Simao
    Poland, Simon P.
    Devauges, Viviane
    Ameer-Beg, Simon M.
    OPTICS LETTERS, 2020, 45 (10) : 2732 - 2735
  • [6] Time-resolved Forster energy transfer in polymer blends
    Dogariu, A
    Gupta, R
    Heeger, AJ
    Wang, H
    SYNTHETIC METALS, 1999, 100 (01) : 95 - 100
  • [7] Time-resolved Forster energy transfer in polymer blends
    Univ of California, Santa Barbara, United States
    IQEC Int Quantum Electron Conf Proc, (201-202):
  • [8] Quantum Dots as Forster Resonance Energy Transfer Acceptors of Lanthanides in Time-Resolved Bioassays
    Diaz, Sebastian A.
    Lasarte-Aragones, Guillermo
    Lowery, Robert G.
    Aniket
    Vranish, James N.
    Klein, William P.
    Susumu, Kimihiro
    Medintz, Igor L.
    ACS APPLIED NANO MATERIALS, 2018, 1 (06): : 3006 - 3014
  • [9] Time-resolved Forster resonance energy transfer assays for the binding of nucleotide and protein substrates to p38α protein kinase
    Zhang, WX
    Wang, RX
    Wisniewski, D
    Marcy, AI
    LoGrasso, P
    Lisnock, JM
    Cummings, RT
    Thompson, JE
    ANALYTICAL BIOCHEMISTRY, 2005, 343 (01) : 76 - 83
  • [10] Time-resolved Forster energy transfer in polymer blends.
    Heeger, AJ
    Dogariu, A
    Gupta, R
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1999, 217 : U443 - U443