Iterative reconstruction for dual energy CT with an average image-induced nonlocal means regularization

被引:40
|
作者
Zhang, Houjin [1 ,2 ]
Zeng, Dong [1 ,2 ]
Lin, Jiahui [1 ,2 ]
Zhang, Hao [4 ]
Bian, Zhaoying [1 ,2 ]
Huang, Jing [1 ,2 ]
Gao, Yuanyuan [1 ,2 ]
Zhang, Shanli [5 ]
Zhang, Hua [1 ,2 ]
Feng, Qianjin [1 ,2 ]
Liang, Zhengrong [6 ,7 ]
Chen, Wufan [1 ,2 ]
Ma, Jianhua [1 ,3 ]
机构
[1] Southern Med Univ, Dept Biomed Engn, Guangzhou 510515, Guangdong, Peoples R China
[2] Southern Med Univ Guangzhou, Guangdong Prov Key Lab Med Image Proc, Guangzhou 510515, Guangdong, Peoples R China
[3] Guangzhou Key Lab Med Radiat Imaging & Detect Tec, Guangzhou 510515, Guangdong, Peoples R China
[4] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD USA
[5] Guangzhou Univ Tradit Chinese Med, Affiliated Hosp 1, Guangzhou, Guangdong, Peoples R China
[6] SUNY Stony Brook, Dept Radiol, Stony Brook, NY 11794 USA
[7] SUNY Stony Brook, Dept Biomed Engn, Stony Brook, NY 11794 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2017年 / 62卷 / 13期
基金
中国国家自然科学基金; 中国博士后科学基金; 美国国家卫生研究院;
关键词
dual-energy CT; aviNLM regularization; low-mAs; iterative image reconstruction; material decomposition; COMPUTED-TOMOGRAPHY; SPECTRAL CT; NOISE-REDUCTION; DECOMPOSITION; ALGORITHMS;
D O I
10.1088/1361-6560/aa7122
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Reducing radiation dose in dual energy computed tomography (DECT) is highly desirable but it may lead to excessive noise in the filtered backprojection (FBP) reconstructed DECT images, which can inevitably increase the diagnostic uncertainty. To obtain clinically acceptable DECT images from low-mAs acquisitions, in this work we develop a novel scheme based on measurement of DECT data. In this scheme, inspired by the success of edge-preserving non-local means (NLM) filtering in CT imaging and the intrinsic characteristics underlying DECT images, i.e. global correlation and non-local similarity, an averaged image induced NLM-based (aviNLM) regularization is incorporated into the penalized weighted least-squares (PWLS) framework. Specifically, the presented NLM-based regularization is designed by averaging the acquired DECT images, which takes the image similarity within the two energies into consideration. In addition, the weighted least-squares term takes into account DECT data-dependent variance. For simplicity, the presented scheme was termed as 'PWLS-aviNLM'. The performance of the presented PWLS-aviNLM algorithm was validated and evaluated on digital phantom, physical phantom and patient data. The extensive experiments validated that the presented PWLS-aviNLM algorithm outperforms the FBP, PWLS-TV and PWLS-NLM algorithms quantitatively. More importantly, it delivers the best qualitative results with the finest details and the fewest noise-induced artifacts, due to the aviNLM regularization learned from DECT images. This study demonstrated the feasibility and efficacy of the presented PWLS-aviNLM algorithm to improve the DECT reconstruction and resulting material decomposition.
引用
收藏
页码:5556 / 5574
页数:19
相关论文
共 50 条
  • [41] Wiener Filter and Iterative Regularization Methods for Solar Image Reconstruction
    Wang, Shuzhen
    Wang, Yinlong
    Xu, Liya
    LISS 2014, 2015, : 635 - 642
  • [42] Iterative image reconstruction for sparse-view CT via total variation regularization and dictionary learning
    Zhao, Xianyu
    Jiang, Changhui
    Zhang, Qiyang
    Ge, Yongshuai
    Liang, Dong
    Liu, Xin
    Yang, Yongfeng
    Zheng, Hairong
    Hu, Zhanli
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2019, 27 (03) : 573 - 590
  • [43] ITERATIVE IMAGE RECONSTRUCTION FOR DUAL-ENERGY X-RAY CT USING REGULARIZED MATERIAL SINOGRAM ESTIMATES
    Huh, Wonseok
    Fessler, Jeffrey A.
    2011 8TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2011, : 1512 - 1515
  • [44] Iterative Image Reconstruction with Variable Resolution in CT
    Zhang, Zheng
    Bian, Junguo
    Han, Xiao
    Pearson, Erik
    Sidky, Emil Y.
    Pan, Xiaochuan
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4155 - 4157
  • [45] Iterative image reconstruction in spectral-CT
    Hernandez, Daniel
    Michel, Eric
    Kim, Hye S.
    Kim, Jae G.
    Han, Byung H.
    Cho, Min H.
    Lee, Soo Y.
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [46] Techniques in Iterative Proton CT Image Reconstruction
    Penfold S.
    Censor Y.
    Sensing and Imaging, 2015, 16 (1):
  • [47] CT Image Reconstruction via Nonlocal Low-Rank Regularization and Data-Driven Tight Frame
    Shen, Yanfeng
    Sun, Shuli
    Xu, Fengsheng
    Liu, Yanqin
    Yin, Xiuling
    Zhou, Xiaoshuang
    SYMMETRY-BASEL, 2021, 13 (10):
  • [48] Compressed sensing image reconstruction via adaptive sparse nonlocal regularization
    Zhiyuan Zha
    Xin Liu
    Xinggan Zhang
    Yang Chen
    Lan Tang
    Yechao Bai
    Qiong Wang
    Zhenhong Shang
    The Visual Computer, 2018, 34 : 117 - 137
  • [49] Compressed sensing image reconstruction via adaptive sparse nonlocal regularization
    Zha, Zhiyuan
    Liu, Xin
    Zhang, Xinggan
    Chen, Yang
    Tang, Lan
    Bai, Yechao
    Wang, Qiong
    Shang, Zhenhong
    VISUAL COMPUTER, 2018, 34 (01): : 117 - 137
  • [50] Combination of global and nonlocal sparse regularization priors for MR image reconstruction
    Mathew, Raji Susan
    Paul, Joseph Suresh
    PROCEEDINGS OF THE 2019 IEEE REGION 10 CONFERENCE (TENCON 2019): TECHNOLOGY, KNOWLEDGE, AND SOCIETY, 2019, : 2680 - 2684