Iterative reconstruction for dual energy CT with an average image-induced nonlocal means regularization

被引:40
|
作者
Zhang, Houjin [1 ,2 ]
Zeng, Dong [1 ,2 ]
Lin, Jiahui [1 ,2 ]
Zhang, Hao [4 ]
Bian, Zhaoying [1 ,2 ]
Huang, Jing [1 ,2 ]
Gao, Yuanyuan [1 ,2 ]
Zhang, Shanli [5 ]
Zhang, Hua [1 ,2 ]
Feng, Qianjin [1 ,2 ]
Liang, Zhengrong [6 ,7 ]
Chen, Wufan [1 ,2 ]
Ma, Jianhua [1 ,3 ]
机构
[1] Southern Med Univ, Dept Biomed Engn, Guangzhou 510515, Guangdong, Peoples R China
[2] Southern Med Univ Guangzhou, Guangdong Prov Key Lab Med Image Proc, Guangzhou 510515, Guangdong, Peoples R China
[3] Guangzhou Key Lab Med Radiat Imaging & Detect Tec, Guangzhou 510515, Guangdong, Peoples R China
[4] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD USA
[5] Guangzhou Univ Tradit Chinese Med, Affiliated Hosp 1, Guangzhou, Guangdong, Peoples R China
[6] SUNY Stony Brook, Dept Radiol, Stony Brook, NY 11794 USA
[7] SUNY Stony Brook, Dept Biomed Engn, Stony Brook, NY 11794 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2017年 / 62卷 / 13期
基金
中国国家自然科学基金; 中国博士后科学基金; 美国国家卫生研究院;
关键词
dual-energy CT; aviNLM regularization; low-mAs; iterative image reconstruction; material decomposition; COMPUTED-TOMOGRAPHY; SPECTRAL CT; NOISE-REDUCTION; DECOMPOSITION; ALGORITHMS;
D O I
10.1088/1361-6560/aa7122
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Reducing radiation dose in dual energy computed tomography (DECT) is highly desirable but it may lead to excessive noise in the filtered backprojection (FBP) reconstructed DECT images, which can inevitably increase the diagnostic uncertainty. To obtain clinically acceptable DECT images from low-mAs acquisitions, in this work we develop a novel scheme based on measurement of DECT data. In this scheme, inspired by the success of edge-preserving non-local means (NLM) filtering in CT imaging and the intrinsic characteristics underlying DECT images, i.e. global correlation and non-local similarity, an averaged image induced NLM-based (aviNLM) regularization is incorporated into the penalized weighted least-squares (PWLS) framework. Specifically, the presented NLM-based regularization is designed by averaging the acquired DECT images, which takes the image similarity within the two energies into consideration. In addition, the weighted least-squares term takes into account DECT data-dependent variance. For simplicity, the presented scheme was termed as 'PWLS-aviNLM'. The performance of the presented PWLS-aviNLM algorithm was validated and evaluated on digital phantom, physical phantom and patient data. The extensive experiments validated that the presented PWLS-aviNLM algorithm outperforms the FBP, PWLS-TV and PWLS-NLM algorithms quantitatively. More importantly, it delivers the best qualitative results with the finest details and the fewest noise-induced artifacts, due to the aviNLM regularization learned from DECT images. This study demonstrated the feasibility and efficacy of the presented PWLS-aviNLM algorithm to improve the DECT reconstruction and resulting material decomposition.
引用
收藏
页码:5556 / 5574
页数:19
相关论文
共 50 条
  • [1] Spectral CT Image Restoration via an Average Image-Induced Nonlocal Means Filter
    Zeng, Dong
    Huang, Jing
    Zhang, Hua
    Bian, Zhaoying
    Niu, Shanzhou
    Zhang, Zhang
    Feng, Qianjin
    Chen, Wufan
    Ma, Jianhua
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (05) : 1044 - 1057
  • [2] Statistical Iterative Reconstruction for Perfusion CT with a Prior-Image Induced Hybrid Nonlocal Means Regularization
    Li, B.
    Lyu, Q.
    Ma, J.
    Wang, J.
    MEDICAL PHYSICS, 2015, 42 (06) : 3638 - 3639
  • [3] Iterative reconstruction for CT perfusion with a prior-image induced hybrid nonlocal means regularization: Phantom studies
    Li, Bin
    Lyu, Qingwen
    Ma, Jianhua
    Wang, Jing
    MEDICAL PHYSICS, 2016, 43 (04) : 1688 - 1699
  • [4] Multi-Energy CT Reconstruction with Spatial Spectral Nonlocal Means Regularization
    Li, B.
    Shen, C.
    Ouyang, L.
    Yang, M.
    Zhou, L.
    Jiang, S.
    Jia, X.
    MEDICAL PHYSICS, 2016, 43 (06) : 3834 - 3834
  • [5] Assessment of prior image induced nonlocal means regularization for low-dose CT reconstruction: Change in anatomy
    Zhang, Hao
    Ma, Jianhua
    Wang, Jing
    Moore, William
    Liang, Zhengrong
    MEDICAL PHYSICS, 2017, 44 (09) : E264 - E278
  • [6] SPECTRAL CT IMAGE RESTORATION USING AVERAGE IMAGE INDUCED NONLOCAL MEANS FILTER
    Zeng, Dong
    Ma, Jianhua
    Zhang, Hua
    ZhaoyingBian
    Niu, Shanzhou
    Huang, Jing
    Chen, Wufan
    2014 IEEE 11th International Symposium on Biomedical Imaging (ISBI), 2014, : 497 - 500
  • [7] Combined iterative reconstruction and image-domain decomposition for dual energy CT using total-variation regularization
    Dong, Xue
    Niu, Tianye
    Zhua, Lei
    MEDICAL PHYSICS, 2014, 41 (05)
  • [8] Adaptive Nonlocal Means-Regularized Iterative Image Reconstruction for Sparse-View CT
    Zhang, Hao
    Ma, Jianhua
    Wang, Jing
    Liu, Yan
    Han, Hao
    Moore, William
    Salerno, Michael
    Liang, Zhengrong
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [9] Statistical image reconstruction for low-dose CT using nonlocal means-based regularization
    Zhang, Hao
    Ma, Jianhua
    Wang, Jing
    Liu, Yan
    Lu, Hongbing
    Liang, Zhengrong
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2014, 38 (06) : 423 - 435
  • [10] Two iterative nonlocal regularization for image restoration
    Hao, Binbin
    Zhu, Jianguang
    Hao, B. (bbhao981@yahoo.com.cn), 1600, Binary Information Press, Flat F 8th Floor, Block 3, Tanner Garden, 18 Tanner Road, Hong Kong (09): : 1005 - 1016