Enlarged glycemic variability in sulfonylurea-treated well-controlled type 2 diabetics identified using continuous glucose monitoring

被引:5
|
作者
Uemura, Fumi [1 ]
Okada, Yosuke [1 ]
Torimoto, Keiichi [1 ]
Tanaka, Yoshiya [1 ]
机构
[1] Univ Occupat & Environm Hlth, Sch Med, Dept Internal Med 1, Yahatanishi Ku, 1-1 Iseigaoka, Kitakyushu, Fukuoka 8078555, Japan
关键词
SEVERE HYPOGLYCEMIA; JAPANESE PATIENTS; ASSOCIATION; COMMITTEE; LEVEL;
D O I
10.1038/s41598-021-83999-z
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Time in range (TIR) is an index of glycemic control obtained from continuous glucose monitoring (CGM). The aim was to compare the glycemic variability of treatment with sulfonylureas (SUs) in type 2 diabetes mellitus (T2DM) with well-controlled glucose level (TIR>70%). The study subjects were 123 patients selected T2DM who underwent CGM more than 24 h on admission without changing treatment. The primary endpoint was the difference in glycemic variability, while the secondary endpoint was the difference in time below range<54 mg/dL; TBR<54, between the SU (n=63) and non-SU (n=60) groups. The standard deviation, percentage coefficient of variation (%CV), and maximum glucose level were higher in the SU group than in the non-SU group, and TBR<54 was longer in the high-dose SU patients. SU treatment was identified as a significant factor that affected %CV (beta: 2.678, p=0.034). High-dose SU use contributed to prolonged TBR<54 (beta: 0.487, p=0.028). Our study identified enlarged glycemic variability in sulfonylurea-treated well-controlled T2DM patients and high-dose SU use was associated with TBR<54. The results highlight the need for careful adjustment of the SU dose, irrespective of glycated hemoglobin level or TIR value.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Aerobic exercise training reverses diastolic dysfunction in uncomplicated well-controlled type 2 diabetics
    Brassard, Patrice
    Legault, Sylvie
    Garneau, Caroline
    Bogaty, Peter
    Dumesnil, Jean G.
    Poirier, Paul
    DIABETES, 2007, 56 : A277 - A277
  • [32] Variability of nocturnal glycaemia related to severity of sleep apnea in type 2 diabetics: results of continuous glucose monitoring
    Pallayova, M.
    Donic, V.
    Tomori, Z.
    DIABETOLOGIA, 2007, 50 : S350 - S350
  • [33] Effect of exenatide (exendin-4) on glycemic control and safety over 30 weeks in sulfonylurea-treated patients with type 2 diabetes
    Buse, J
    Henry, R
    Han, J
    Kim, DD
    Fineman, M
    Baron, AD
    DIABETES, 2004, 53 : A82 - A82
  • [34] 1, 5-Anhydroglucitol as a marker of short term glucose variability in well-controlled type 2 diabetes mellitus
    Lee, Y. J.
    Suh, K. S.
    Choi, M. C.
    Hwang, Y. C.
    Chon, S.
    Jeong, I-K.
    Oh, S.
    Ahn, K. J.
    Chung, H. Y.
    Woo, J. -T.
    Kim, S. -W.
    Kim, J. -W.
    Choi, Y. K.
    Kim, Y. S.
    DIABETOLOGIA, 2010, 53
  • [35] Association of glycemic variability assessed by continuous glucose monitoring with subclinical diabetic polyneuropathy in type 2 diabetes patients
    Pan, Jiemin
    Yan, Xinfeng
    Li, Fengwen
    Zhang, Yinan
    Jiang, Lan
    Wang, Congrong
    JOURNAL OF DIABETES INVESTIGATION, 2022, 13 (02) : 328 - 335
  • [36] Glycemic variability in continuous glucose monitoring is inversely associated with baroreflex sensitivity in type 2 diabetes: a preliminary report
    Daisuke Matsutani
    Masaya Sakamoto
    Hiroyuki Iuchi
    Souichirou Minato
    Hirofumi Suzuki
    Yosuke Kayama
    Norihiko Takeda
    Ryuzo Horiuchi
    Kazunori Utsunomiya
    Cardiovascular Diabetology, 17
  • [37] Ischemic Heart Disease and Type 2 Diabetes Complications Are Associated with Glycemic Variability Measured by Continuous Glucose Monitoring
    Hertzberg, Jeffrey K.
    Janer, Ciara
    Jhuang, An-Ting
    Santos, Alix J.
    Kibanoff, Nathan
    Vojta, Deneen
    Wiegand, Ben
    Murillo, Jaime
    CIRCULATION, 2021, 144
  • [38] Glycemic variability in continuous glucose monitoring is inversely associated with baroreflex sensitivity in type 2 diabetes: a preliminary report
    Matsutani, Daisuke
    Sakamoto, Masaya
    Iuchi, Hiroyuki
    Minato, Souichirou
    Suzuki, Hirofumi
    Kayama, Yosuke
    Takeda, Norihiko
    Horiuchi, Ryuzo
    Utsunomiya, Kazunori
    CARDIOVASCULAR DIABETOLOGY, 2018, 17
  • [39] From Stability to Variability: Classification of Healthy Individuals, Prediabetes, and Type 2 Diabetes Using Glycemic Variability Indices from Continuous Glucose Monitoring Data
    Cichosz, Simon Lebech
    Kronborg, Thomas
    Laugesen, Esben
    Hangaard, Stine
    Fleischer, Jesper
    Hansen, Troels Krarup
    Jensen, Morten Hasselstrom
    Poulsen, Per Logstrup
    Vestergaard, Peter
    DIABETES TECHNOLOGY & THERAPEUTICS, 2025, 27 (01) : 34 - 44
  • [40] Evaluating Rate of Change as an Index of Glycemic Variability, Using Continuous Glucose Monitoring Data
    Whitelaw, Benjamin C.
    Choudhary, Pratik
    Hopkins, David
    DIABETES TECHNOLOGY & THERAPEUTICS, 2011, 13 (06) : 631 - 636