A new G-M counter dead time model

被引:47
|
作者
Lee, SH [1 ]
Gardner, RP [1 ]
机构
[1] N Carolina State Univ, Ctr Engn Applicat Radioisotopes, Raleigh, NC 27695 USA
关键词
G-M counter model; G-M counter dead time; dead time model;
D O I
10.1016/S0969-8043(00)00261-X
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A hybrid G-M counter dead time model was derived by combining the idealized paralyzable and non-paralyzable models. The new model involves two parameters, which are the paralyzable and non-paralyzable dead times. The dead times used in the model are very closely related to the physical dead time of the G-M tube and its resolving time. To check the validity of the model, the decaying source method with Mn-56 was used. The corrected counting rates by the new G-M dead time model were compared with the observed counting rates obtained from the measurement and gave very good agreement within 5% up to 7 x 10(4) counts/s for a G-M tube with a dead time of about 300 mu s. (C) 2000 Published by Elsevier Science Ltd.
引用
收藏
页码:731 / 737
页数:7