Can the global end-diastolic volume index guide fluid management in septic patients? A multicenter randomized controlled trial

被引:2
|
作者
Morisawa, Kenichiro [1 ]
Fujitani, Shigeki [1 ]
Homma, Yosuke [2 ]
Shigemitsu, Kazuaki [3 ]
Saito, Nobuyuki [4 ]
Hayakawa, Katsura [5 ]
Yasuda, Hideto [6 ]
Hifumi, Toru [7 ]
Rinka, Hiroshi [3 ]
Mayumi, Toshihiko [8 ]
Fujiwara, Shinsuke [9 ]
Murao, Yoshinori [10 ]
Taira, Yasuhiko [1 ]
机构
[1] St Marianna Univ, Sch Med, Dept Emergency & Crit Care Med, 2-16-1 Sugao, Kawasaki, Kanagawa, Japan
[2] Tokyo Bay Urayasu Ichikawa Med Ctr, Dept Emergency & Crit Care Med, Urayasu, Chiba, Japan
[3] Osaka City Gen Hosp, Emergency & Crit Care Med Ctr, Miyakojima Ku, Osaka, Japan
[4] Chiba Hokusou Hosp, Nippon Med Sch, Inzai, Chiba, Japan
[5] Saitama Red Cross Hosp, Dept Emergency & Crit Care Med, Saitama, Saitama, Japan
[6] Japanese Red Cross Musashino Hosp, Musashino, Tokyo, Japan
[7] Kagawa Univ Hosp, Miki, Kagawa, Japan
[8] Univ Occupat & Environm Hlth, Sch Med, Dept Emergency Med, Kitakyushu, Fukuoka, Japan
[9] Natl Hosp Org Ureshino Med Ctr, Dept Emergency Med, Ureshino, Saga, Japan
[10] Kindai Univ, Fac Med, Dept Emergency & Crit Care Med, Osakasayama, Osaka, Japan
来源
ACUTE MEDICINE & SURGERY | 2020年 / 7卷 / 01期
关键词
Early goal-directed therapy; global end-diastolic volume index; sepsis; transpulmonary thermodilution; volume resuscitation; GOAL-DIRECTED RESUSCITATION; SEPSIS; INDICATOR; OUTCOMES; SHOCK;
D O I
10.1002/ams2.468
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim An index that accurately measures intravascular volume is paramount for the optimal resuscitation of sepsis. Selecting an adequate indicator to substitute for central venous pressure (CVP) has remained an issue. The objective of our study was to compare the usefulness of standard early goal-directed therapy (EGDT) with CVP (EGDT-CVP) and modified EGDT with global end-diastolic volume index (GEDI; EGDT-GEDI) for sepsis. Methods This was a multicenter prospective randomized controlled study. All patients with sepsis who were expected to require mechanical ventilator support for a minimum of 48 h were included. The patients were classified into an EGDT-CVP group and an EGDT-GEDI group. All participants underwent the extubation protocol. The primary outcome was the ventilator-free days over a 28-day period. Results The ventilator-free days was not significantly different between the two groups (P = 0.59). However, the EGDT-GEDI group showed a trend of shorter ventilator support duration (5.1 days [2.0-8.7 days] versus 3.9 days [2.4-5.7 days], P = 0.27) and length of stay in the intensive care unit (7.2 days [3.8-10.7 days] versus 5.1 days [3.7-8.8 days], P = 0.05) and a smaller 3-day infusion balance than the EGDT-CVP group (4,405 mL [1,092-8,163 mL] versus 3,046 mL [830-6,806 mL], P = 0.34), but the differences were not statistically significant. Conclusion Although there was no significant efficacy, EGDT guided by GEDI showed a trend of shorter length of stay in the intensive care unit and lower 3-day infusion balance than the EGDT-CVP group in sepsis. The GEDI monitoring did not appear to improve the ventilator-free days over a 28-day period.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Effects of TIPS on global end-diastolic volume and cardiac output and renal resistive index in ICU patients with advanced alcoholic cirrhosis
    Umgelter, Andreas
    Reindl, Wolfgang
    Geisler, Fabian
    Saugel, Bernd
    Huber, Wolfgang
    Berger, Hermann
    Schmid, Roland M.
    ANNALS OF HEPATOLOGY, 2010, 9 (01) : 40 - 45
  • [22] Inferior Vena Cava Collapsibility Index is a Valuable and Non-Invasive Index for Elevated General Heart End-Diastolic Volume Index Estimation in Septic Shock Patients
    Zhao, Jie
    Wang, Guolin
    MEDICAL SCIENCE MONITOR, 2016, 22 : 3843 - 3848
  • [23] Limitations of global end-diastolic volume index as a parameter of cardiac preload in the early phase of severe sepsis: A subgroup analysis of a multicenter, prospective observational study
    Endo T.
    Kushimoto S.
    Yamanouchi S.
    Sakamoto T.
    Ishikura H.
    Kitazawa Y.
    Taira Y.
    Okuchi K.
    Tagami T.
    Watanabe A.
    Yamaguchi J.
    Yoshikawa K.
    Sugita M.
    Kase Y.
    Kanemura T.
    Takahashi H.
    Kuroki Y.
    Izumino H.
    Rinka H.
    Seo R.
    Takatori M.
    Kaneko T.
    Nakamura T.
    Irahara T.
    Saito N.
    PiCCO Pulmonary Edema Study Group
    Journal of Intensive Care, 1 (1)
  • [24] Right ventricular end-diastolic volume index as a predictor of preload status in patients on positive end-expiratory pressure
    Cheatham, ML
    Nelson, LD
    Chang, MC
    Safcsak, K
    CRITICAL CARE MEDICINE, 1998, 26 (11) : 1801 - 1806
  • [25] Relationship of stroke volume variation, pulse pressure variation and global end-diastolic volume in patients undergoing brain surgery
    A Rieß
    S Wolf
    C Lumenta
    L Schürer
    P Friederich
    Critical Care, 14 (Suppl 1):
  • [26] VOLUME ASSESSMENT IN PATIENTS DURING MAJOR LIVER RESECTIONS: A COMPARISON OF GLOBAL END-DIASTOLIC VOLUME, CENTRAL VENOUS PRESSURE AND THEIR CORRELATION TO CARDIAC INDEX AND EXTRAVASCULAR LUNG WATER INDEX
    Redondo Calvo, F. J.
    Villazala, R.
    Madrazo, M.
    Padilla, D.
    Yuste, A.
    Baladron, V.
    Gernal, G.
    INTENSIVE CARE MEDICINE, 2010, 36 : S378 - S378
  • [27] EXTRACORPOREAL CYTOKINE HEMOADSORPTION IN SEVERELY SEPTIC PATIENTS: A MULTICENTER RANDOMIZED CONTROLLED TRIAL
    Schaedler, D.
    Porzilius, C.
    Brederlau, J.
    Joerres, A.
    Marx, G.
    Meier-Hellmann, A.
    Putensen, C.
    Quintel, M.
    Spies, C. D.
    Engel, C.
    Kellurn, J.
    Weiler, N.
    Kuhlmann, M. K.
    INTENSIVE CARE MEDICINE, 2013, 39 : S214 - S214
  • [28] Intrathoracic blood volume and global end-diastolic volume should be included among indexes used in intensive care for assessment of fluid responsiveness in spontaneously breathing patients
    Perel, Azriel
    CRITICAL CARE MEDICINE, 2006, 34 (08) : 2266 - 2267
  • [29] Transpulmonary thermodilution: A revised correction formula for global end-diastolic volume index derived after femoral indicator injection
    Schuster, Hannah
    Haller, Bernhard
    Sancak, Sengul
    Erber, Johanna
    Schmid, Roland M.
    Lahmer, Tobias
    Rasch, Sebastian
    MATHEMATICAL BIOSCIENCES AND ENGINEERING, 2023, 20 (06) : 9876 - 9890
  • [30] Calculated global end-diastolic volume does not correspond to the largest heart blood volume: a bias for cardiac function index? Authors' reply
    Combes, A
    INTENSIVE CARE MEDICINE, 2004, 30 (11) : 2135 - 2135