A Comparison of Five Algorithms for Fetal Magnetocardiography Signal Extraction

被引:9
|
作者
Escalona-Vargas, Diana [1 ]
Wu, Hau-tieng [2 ,3 ,4 ]
Frasch, Martin G. [5 ]
Eswaran, Hari [1 ]
机构
[1] Univ Arkansas Med Sci, Dept Obstet & Gynecol, 4301 West Markham St,518, Little Rock, AR 72205 USA
[2] Duke Univ, Dept Math, Durham, NC 27706 USA
[3] Duke Univ, Dept Stat Sci, Durham, NC USA
[4] Natl Ctr Theoret Sci, Div Math, Taipei, Taiwan
[5] Univ Washington, Dept Obstet & Gynecol, Seattle, WA 98195 USA
关键词
Fetal magnetocardiography; Signal processing; Cardiac time intervals; Variability analysis; FREQUENCY-DEPENDENT SUBTRACTION; IN-UTERO; PROJECTION OPERATORS; MEG; HEART; BRAIN;
D O I
10.1007/s13239-018-0351-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Fetal magnetocardiography (fMCG) provides accurate and reliable measurements of electrophysiological events in the fetal heart and is capable of studying fetuses with congenital heart diseases. A variety of techniques exist to extract the fMCG signal with the demand for non-invasively obtained fetal cardiac information. To the best of our knowledge, there is no comparative study published in the field as to how the various extraction algorithms perform. We perform a comparative study of the ability of five methods to extract the fMCG using real biomagnetic signals, two of those methods are applied to real fMCG data for the first time. Biomagnetic signals were recorded and processed with each of the five methods to obtain fMCG. The R peaks of the fMCG traces were obtained via a peak-detection algorithm. From whole recording for each method, the fetal heart rate (FHR) was calculated and used to perform FHR variability (FHRV) analysis. Additionally, we calculated durations from the PQRST complex from time-averaged data during sinus rhythm. The five methods recovered the fMCG signals, but two of them were able to extract cleaner fMCG and the morphology was observed from the continuous data. The time-averaged data showed very similar morphologies between methods, but two of them displayed a signal amplitude reduction on the R-waves and T-waves. Values of PQRST durations, FHR and FHRV were in the range of previous fetal cardiac studies. We have compared five methods for fMCG extraction and showed their ability to perform fMCG analysis.
引用
收藏
页码:483 / 487
页数:5
相关论文
共 50 条
  • [31] ANTENATAL FETAL MAGNETOCARDIOGRAPHY - A NEW METHOD FOR FETAL SURVEILLANCE
    QUINN, A
    WEIR, A
    SHAHANI, U
    BAIN, R
    MAAS, P
    DONALDSON, G
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1994, 101 (10): : 866 - 870
  • [32] Performance Evaluation of Fetal ECG Extraction Algorithms
    Kaleem, Abdullah Mohammed
    Kokate, Rajendra D.
    [J]. EMERGING RESEARCH IN ELECTRONICS, COMPUTER SCIENCE AND TECHNOLOGY, ICERECT 2018, 2019, 545 : 187 - 194
  • [33] Comparison of atrial signal extraction algorithms in 12-lead ECGs with atrial fibrillation
    Langley, P
    Rieta, JJ
    Stridh, M
    Millet, J
    Sömmo, L
    Murray, A
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (02) : 343 - 346
  • [34] Comparison of magnetocardiography and electrocardiography
    Smith, Fiona E.
    Langley, Philip
    van Leeuwen, Peter
    Hailer, Birgit
    Trahms, Lutz
    Steinhoff, Uwe
    Bourke, John P.
    Murray, Alan
    [J]. ANADOLU KARDIYOLOJI DERGISI-THE ANATOLIAN JOURNAL OF CARDIOLOGY, 2007, 7 : 20 - 22
  • [35] Usefulness of magnetocardiography for the investigation of fetal arrhythmias
    Menéndez, T
    Achenbach, S
    Beinder, E
    Hofbeck, M
    Klinghammer, L
    Singer, H
    Moshage, W
    Daniel, WG
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (03): : 334 - +
  • [36] Assessment of Fetal Autonomic Nervous System Activity by Fetal Magnetocardiography: Comparison of Normal Pregnancy and Intrauterine Growth Restriction
    Fukushima, Akimune
    Nakai, Kenji
    Kanasugi, Tomonobu
    Terata, Miyuki
    Sugiyama, Toru
    [J]. JOURNAL OF PREGNANCY, 2011, 2011 : 218162
  • [37] A comparison of five different algorithms for EEG signal analysis in artifacts rejection for monitoring depth of anesthesia
    Liu, Quan
    Chen, Yi-Feng
    Fan, Shou-Zen
    Abbod, Maysam F.
    Shieh, Jiann-Shing
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2016, 25 : 24 - 34
  • [38] Application of SQUID magnetometers in fetal magnetocardiography
    Rijpma, AP
    Seppenwoolde, Y
    ter Brake, HJM
    Peters, MJ
    Rogalla, H
    [J]. APPLIED SUPERCONDUCTIVITY 1997, VOLS 1 AND 2: VOL 1: SMALL SCALE AND ELECTRONIC APPLICATIONS; VOL 2: LARGE SCALE AND POWER APPLICATIONS, 1997, (158): : 771 - 774
  • [39] Optical magnetometer array for fetal magnetocardiography
    Wyllie, Robert
    Kauer, Matthew
    Wakai, Ronald T.
    Walker, Thad G.
    [J]. OPTICS LETTERS, 2012, 37 (12) : 2247 - 2249
  • [40] New insights into fetal atrioventricular block using fetal magnetocardiography
    Hornberger, Lisa K.
    Collins, Kathryn
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (01) : 85 - 86