Noninvasive point-of-care measurement of gastrointestinal permeability

被引:0
|
作者
Dorshow, Richard B. [1 ]
Johnson, J. R. [1 ]
Debreczeny, Martin P. [1 ]
Riley, I. Rochelle [1 ]
Shieh, Jeng-Jong [1 ]
Rogers, Thomas E. [1 ]
Hall-Moore, Carla [2 ]
Shaikh, Nurmohammad [2 ]
Tarr, Phillip, I [2 ]
机构
[1] MediBeacon Inc, 1100 Corp Sq Dr, St Louis, MO 63132 USA
[2] Washington Univ, Dept Pediat, Sch Med, St Louis, MO 63110 USA
基金
比尔及梅琳达.盖茨基金会;
关键词
gastrointestinal permeability; fluorescence tracer agent; dual sugar absorption test; enteropathy; point-of-care measurement;
D O I
10.1117/12.2507965
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The intestinal mucosal barrier prevents macromolecules and pathogens from entering the circulatory stream in a healthy gut. Tight junctions in this barrier are compromised in many intestinal disorders including inflammatory bowel diseases (such as Crohn's and ulcerative colitis), celiac disease, graft vs host disease, environmental enteropathy, and enteric dysfunction. Dual sugar absorption tests are a standard method for measuring gastrointestinal integrity in humans. The larger molecular weight sugar, lactulose, is minimally absorbed through a healthy gut. The smaller molecular weight sugar, mannitol or rhamnose, in contrast, is readily absorbed through both a healthy and inflamed gut. Thus, a higher ratio of lactulose to mannitol or rhamnose reflects increased intestinal permeability. However, several issues prevent the widespread use of the dual sugar assay including requirements for lengthy urine collection, transport of specimens under conditions free from contamination and bacterial growth, analysis by sophisticated laboratory equipment, and the associated lengthy turnaround time. In a recent publication, the feasibility of employing a dual fluorescent tracer agent assay to mimic the dual sugar absorption test without the need for specimen collection was reported. This dual fluorophore assay for GI permeability was demonstrated in an indomethacin-induced bowel disease model in rats. However, one of the fluorophores was not entirely biocompatible. Herein is reported a dual fluorophore system that is totally biocompatible, with emphasis on the transdermal detection of the fluorophores, thus enabling the use of the technology for noninvasive point-of-care gastrointestinal permeability determination.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Novel noninvasive point-of-care device for real time hemoglobin monitoring
    Timm, Ulrich
    Gewiss, Helge
    Kraitl, Jens
    Stuepmann, Kirstin
    Hinz, Michael
    Koball, Sebastian
    Ewald, Hartmut
    OPTICAL DIAGNOSTICS AND SENSING XIV: TOWARD POINT-OF-CARE DIAGNOSTICS, 2014, 8951
  • [22] Biosensors for point-of-care testing and personalized monitoring of gastrointestinal microbiota
    Ngashangva, Lightson
    Chattopadhyay, Santanu
    FRONTIERS IN MICROBIOLOGY, 2023, 14
  • [23] Quantitative Measurement of Deformational Plagiocephaly and Brachycephaly at the Point-of-care
    Seifabadi, Reza
    Aalamifar, Fereshteh
    Hezaveh, S. Hossein
    Kocabalkanli, Can
    Linguraru, Marius George
    MEDICAL IMAGING 2021: COMPUTER-AIDED DIAGNOSIS, 2021, 11597
  • [24] Point-of-care testing applications in the measurement of intestinal inflammation
    Gildner, Theresa E.
    Manthey-Pierce, Courtney C.
    Weaver, Samantha
    Zhang, Angela
    Deleger, Julie
    Cepon-Robins, Tara J.
    AMERICAN JOURNAL OF HUMAN BIOLOGY, 2022, 34
  • [25] Measurement of Cardiac Output by Point-of-Care Transthoracic Echocardiography
    Talan, Jordan W.
    Mangalick, Keshav
    Pradhan, Deepak
    Sauthoff, Harald
    ATS SCHOLAR, 2022, 3 (04): : 631 - 633
  • [26] Validation of the Mission Point-of-care device for haemoglobin measurement
    Louw, Susan
    Mayne, Anthony Leland Hamilton
    Wan, Yuen On
    Mayne, Elizabeth
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2021, 43 (01) : E9 - E11
  • [27] Point-of-care noninvasive hemoglobin determination using fiber optic reflectance spectroscopy
    Jay, Gregory D.
    Racht, Justin
    McMurdy, John
    Mathews, Zara
    Hughes, Ashley
    Suner, Selim
    Crawford, Gregory
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 2932 - +
  • [28] Point-of-care noninvasive hemoglobin determination employing fiber optic reflectance spectroscopy
    Intwala, S.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2010, 12 (0F) : F117 - F117
  • [29] The point of point-of-care testing
    Kassaye, Seble G.
    Katzenstein, David
    LANCET, 2011, 378 (9802): : 1532 - 1533
  • [30] Reliability of Point-of-Care Hematocrit Measurement during Liver Transplantation
    Kwon, S. M.
    Lee, H. -C
    Hur, M.
    Ryu, H. -G
    Kim, W. H.
    Jung, C. -W
    TRANSPLANTATION, 2017, 101 (05) : 18 - 18