Noninvasive point-of-care measurement of gastrointestinal permeability

被引:0
|
作者
Dorshow, Richard B. [1 ]
Johnson, J. R. [1 ]
Debreczeny, Martin P. [1 ]
Riley, I. Rochelle [1 ]
Shieh, Jeng-Jong [1 ]
Rogers, Thomas E. [1 ]
Hall-Moore, Carla [2 ]
Shaikh, Nurmohammad [2 ]
Tarr, Phillip, I [2 ]
机构
[1] MediBeacon Inc, 1100 Corp Sq Dr, St Louis, MO 63132 USA
[2] Washington Univ, Dept Pediat, Sch Med, St Louis, MO 63110 USA
基金
比尔及梅琳达.盖茨基金会;
关键词
gastrointestinal permeability; fluorescence tracer agent; dual sugar absorption test; enteropathy; point-of-care measurement;
D O I
10.1117/12.2507965
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The intestinal mucosal barrier prevents macromolecules and pathogens from entering the circulatory stream in a healthy gut. Tight junctions in this barrier are compromised in many intestinal disorders including inflammatory bowel diseases (such as Crohn's and ulcerative colitis), celiac disease, graft vs host disease, environmental enteropathy, and enteric dysfunction. Dual sugar absorption tests are a standard method for measuring gastrointestinal integrity in humans. The larger molecular weight sugar, lactulose, is minimally absorbed through a healthy gut. The smaller molecular weight sugar, mannitol or rhamnose, in contrast, is readily absorbed through both a healthy and inflamed gut. Thus, a higher ratio of lactulose to mannitol or rhamnose reflects increased intestinal permeability. However, several issues prevent the widespread use of the dual sugar assay including requirements for lengthy urine collection, transport of specimens under conditions free from contamination and bacterial growth, analysis by sophisticated laboratory equipment, and the associated lengthy turnaround time. In a recent publication, the feasibility of employing a dual fluorescent tracer agent assay to mimic the dual sugar absorption test without the need for specimen collection was reported. This dual fluorophore assay for GI permeability was demonstrated in an indomethacin-induced bowel disease model in rats. However, one of the fluorophores was not entirely biocompatible. Herein is reported a dual fluorophore system that is totally biocompatible, with emphasis on the transdermal detection of the fluorophores, thus enabling the use of the technology for noninvasive point-of-care gastrointestinal permeability determination.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Transdermal fluorescence detection of a dual fluorophore system for noninvasive point-of-care gastrointestinal permeability measurement
    Dorshow, Richard B.
    Johnson, J. R.
    Debreczeny, Martin P.
    Riley, I. Rochelle
    Shieh, Jeng-Jong
    Rogers, Thomas E.
    Hall-Moore, Carla
    Shaikh, Nurmohammad
    Rouggly-Nickless, L. Colleen
    Tarr, Phillip, I
    BIOMEDICAL OPTICS EXPRESS, 2019, 10 (10) : 5103 - 5116
  • [2] Application of Fluorescent Tracer Agent Technology to Point-of-Care Gastrointestinal Permeability Measurement
    Dorshow, Richard B.
    Shieh, Jeng-Jong
    Rogers, Thomas E.
    Hall-Moore, Carla
    Shaikh, Nurmohammad
    Talcott, Michael
    Tarr, Phillip I.
    REPORTERS, MARKERS, DYES, NANOPARTICLES, AND MOLECULAR PROBES FOR BIOMEDICAL APPLICATIONS VIII, 2016, 9723
  • [3] Accuracy of Noninvasive and Invasive Point-of-Care Hemoglobin Measurement in the Emergency Department
    Wager, A.
    Thomas, A. W.
    Sewatsky, T. P.
    Boas, S.
    O'keefe, M. F.
    Freeman, K.
    ANNALS OF EMERGENCY MEDICINE, 2013, 62 (04) : S41 - S41
  • [4] Permeability in wearable point-of-care systems
    Fang, Yunsheng
    Ji, Junru
    Xu, Feng
    MATTER, 2023, 6 (05) : 1327 - 1330
  • [5] NONINVASIVE POINT-OF-CARE MEASUREMENT OF GUT PERMEABILTIY IN A RAT INDOMETHACIN INJURY MODEL
    Debreczeny, Martin P.
    Dorshow, Richard
    Johnson, James R.
    Riley, I. R.
    Rogers, Thomas E.
    Shieh, Jeng J.
    Hall-Moore, Carla
    Rouggly-Nickless, Lucina C.
    Shaikh, Nurmohammad
    Tarr, Phillip I.
    GASTROENTEROLOGY, 2019, 156 (06) : S698 - S698
  • [6] Point-of-care Ultrasound of the Gastrointestinal Tract
    Gilja, Odd Helge
    Nylund, Kim
    JOURNAL OF MEDICAL ULTRASOUND, 2023, 31 (01) : 1 - 7
  • [7] Comparison of noninvasive and invasive point-of-care testing methods with reference method for hemoglobin measurement
    Avcioglu, Gamze
    Nural, Cemil
    Yilmaz, Fatma Meric
    Baran, Pervin
    Erel, Ozcan
    Yilmaz, Gulsen
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2018, 32 (03)
  • [8] Accuracy of Noninvasive and Invasive Point-of-Care Total Blood Hemoglobin Measurement in an Outpatient Setting
    Raikhel, Marina
    POSTGRADUATE MEDICINE, 2012, 124 (04) : 250 - 255
  • [9] Point-of-Care Noninvasive Technology for Pediatric Dehydration Assessment
    Sheridan, David C.
    Kohn-Loncarica, Guillermo A.
    Nunez, Pedro
    Hudson, Rebekah
    Lin, Amber
    Samatham, Ravi
    Hansen, Matthew L.
    PEDIATRIC EMERGENCY CARE, 2023, 39 (08) : 569 - 573
  • [10] The accuracy of point-of-care glucose measurement
    O'Kane, Maurice J.
    ANNALS OF CLINICAL BIOCHEMISTRY, 2012, 49 : 108 - 109