Indoor thermal environmental conditions near glazed facades with shading devices - Part II: Thermal comfort simulation and impact of glazing and shading properties
被引:85
|
作者:
Tzempelikos, A.
论文数: 0引用数: 0
h-index: 0
机构:
Purdue Univ, Sch Civil Engn, W Lafayette, IN 47907 USAPurdue Univ, Sch Civil Engn, W Lafayette, IN 47907 USA
Tzempelikos, A.
[1
]
Bessoudo, M.
论文数: 0引用数: 0
h-index: 0
机构:
Concordia Univ, Dept Bldg Civil & Environm Engn, Montreal, PQ H3G 1M8, CanadaPurdue Univ, Sch Civil Engn, W Lafayette, IN 47907 USA
Bessoudo, M.
[2
]
Athienitis, A. K.
论文数: 0引用数: 0
h-index: 0
机构:
Concordia Univ, Dept Bldg Civil & Environm Engn, Montreal, PQ H3G 1M8, CanadaPurdue Univ, Sch Civil Engn, W Lafayette, IN 47907 USA
Athienitis, A. K.
[2
]
Zmeureanu, R.
论文数: 0引用数: 0
h-index: 0
机构:
Concordia Univ, Dept Bldg Civil & Environm Engn, Montreal, PQ H3G 1M8, CanadaPurdue Univ, Sch Civil Engn, W Lafayette, IN 47907 USA
Zmeureanu, R.
[2
]
机构:
[1] Purdue Univ, Sch Civil Engn, W Lafayette, IN 47907 USA
Thermal comfort;
Facades;
Glazing;
Shading;
Energy use;
PROJECTED AREA FACTORS;
ENERGY-CONSUMPTION;
SOLAR-RADIATION;
ADAPTIVE MODEL;
TEMPERATURE;
D O I:
10.1016/j.buildenv.2010.05.014
中图分类号:
TU [建筑科学];
学科分类号:
0813 ;
摘要:
This second part of the study uses a validated dynamic building thermal model for perimeter zones with glass facades (described in Part I) and combines it with a transient two-node thermal comfort model. The objective is to investigate the impact of varying exterior climatic conditions, glazing properties and shading properties on indoor thermal comfort and heating demand in such spaces under the presence of transmitted solar radiation. It is evident that selecting appropriate fenestration components becomes a trade-off between energy, thermal comfort, and lighting needs. Facades with insulating and low transmittance glass create more comfortable and stable conditions; however, there is a relationship between lower transmittance of the glazing and increased demand of primary heating needed, as well as with lighting energy use. Regardless of glazing type, shading can improve comfort conditions by decreasing radiant temperature asymmetry and extremes in operative temperature. The results show that perimeter building zones with high-performance facades (glazing and shading) can maintain comfortable conditions and even eliminate the need for secondary perimeter heating in cold climates. (C) 2010 Elsevier Ltd. All rights reserved.
机构:
Univ Lyon, Univ Claude Bernard Lyon 1, CNRS, INSA Lyon,CETHIL UMR5008, F-69621 Lyon, France
Joint Lab CETHIL EDF, BHEE High Energy Efficiency Bldg, Villeurbanne, FranceUniv Lyon, Univ Claude Bernard Lyon 1, CNRS, INSA Lyon,CETHIL UMR5008, F-69621 Lyon, France
Merlier, Lucie
Frayssinet, Loic
论文数: 0引用数: 0
h-index: 0
机构:
Univ Lyon, Univ Claude Bernard Lyon 1, CNRS, INSA Lyon,CETHIL UMR5008, F-69621 Lyon, France
Joint Lab CETHIL EDF, BHEE High Energy Efficiency Bldg, Villeurbanne, FranceUniv Lyon, Univ Claude Bernard Lyon 1, CNRS, INSA Lyon,CETHIL UMR5008, F-69621 Lyon, France
Frayssinet, Loic
Johannes, Kevyn
论文数: 0引用数: 0
h-index: 0
机构:
Univ Lyon, Univ Claude Bernard Lyon 1, CNRS, INSA Lyon,CETHIL UMR5008, F-69621 Lyon, France
Joint Lab CETHIL EDF, BHEE High Energy Efficiency Bldg, Villeurbanne, FranceUniv Lyon, Univ Claude Bernard Lyon 1, CNRS, INSA Lyon,CETHIL UMR5008, F-69621 Lyon, France
Johannes, Kevyn
Kuzni, Frederic
论文数: 0引用数: 0
h-index: 0
机构:
Univ Lyon, Univ Claude Bernard Lyon 1, CNRS, INSA Lyon,CETHIL UMR5008, F-69621 Lyon, France
Joint Lab CETHIL EDF, BHEE High Energy Efficiency Bldg, Villeurbanne, FranceUniv Lyon, Univ Claude Bernard Lyon 1, CNRS, INSA Lyon,CETHIL UMR5008, F-69621 Lyon, France