Parametric study on rectangular finned elliptical tube heat exchangers with the increase of number of rows

被引:13
|
作者
Zhao, Lanping [1 ]
Wang, Renjie [1 ]
Gu, Xitao [1 ]
Yang, Zhigang [2 ,3 ]
机构
[1] Tongji Univ, Sch Mech Engn, Inst Refrigerat & Cryogen Engn, Shanghai, Peoples R China
[2] Shanghai Key Lab Vehicle Aerodynam & Vehicle Ther, Shanghai, Peoples R China
[3] Beijing Aeronaut Sci & Technol Res Inst, Beijing, Peoples R China
关键词
Rectangular finned elliptical tube heat exchanger (RFETHX); Airside thermal-hydraulic characteristics; Number of rows; Interaction effect; Contribution ratio; Response surface method (RSM); THERMAL-HYDRAULIC CHARACTERISTICS; AIR-SIDE PERFORMANCE; PLATE-FIN; FRICTION CHARACTERISTICS; VORTEX GENERATORS; TAGUCHI METHOD; NUMERICAL-ANALYSIS; DESIGN PARAMETERS; DELTA-WINGLETS; OPTIMIZATION;
D O I
10.1016/j.ijheatmasstransfer.2018.05.036
中图分类号
O414.1 [热力学];
学科分类号
摘要
The objective of this study is to investigate the performance of rectangular finned elliptical tube heat exchangers (RFETHXs) of low number of rows (N) in turbulent region, with an emphasis on the characteristics with the increase of N. Using 3D numerical simulations based on the validated standard k-epsilon turbulence model, the average thermal-hydraulic characteristics of each row as well as the overall performance along with N are investigated. Then the contribution of each structural factor and the interaction effects between various parameters on the performance are revealed using variance analysis in 4 sub-row-regions. The most significant interaction effect on the performance evaluation criterion (PEC) between structural parameters is confirmed using Response Surface Method (RSM). It is observed that, for the RFETHXs with N > 2, the heat transfer coefficient of the second row of fins is the largest, while those of the first and the last rows remain the smallest two. A 2-row RFETHX has better performance compared to the RFETHXs with larger N. In most cases, the flow and heat transfer of RFETHXs enters fully developed state from the fifth row, but as the transverse tube pitch (P-t) increases or the fin thickness declines, such state is postponed to deeper rows. It demonstrates that significant impact of N on PEC exists in the sub-row-range of 2-3. With the incline of N, the effect of fin pitch (F-p) to j and f decreases while that of P-t increases, and the interaction effect between P-t and F-p to j and PEC becomes more pronounced. This interaction reduces with the increase of frontal velocity. The reason for such interaction is discussed. At last, results of RMS analysis further depict that the interaction effect between P-t and F-p on PEC of a 6-row RFETHX is more significant than that of a 2-row RFETHX. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:871 / 893
页数:23
相关论文
共 50 条
  • [41] Determination of the Number of Tube Rows to Obtain Closure for Volume Averaging Theory Based Model of Fin-and-Tube Heat Exchangers
    Zhou, Feng
    Hansen, Nicholas E.
    Geb, David J.
    Catton, Ivan
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2011, 133 (12):
  • [42] Parameter study on the fouling characteristics of the H-type finned tube heat exchangers
    Wang, Fei-Long
    He, Ya-Ling
    Tang, Song-Zhen
    Tong, Zi-Xiang
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 112 : 367 - 378
  • [43] Heat transfer and pressure loss penalty for the number of tube rows of staggered finned-tube bundles with a single transverse row of winglets
    Kwak, KM
    Torii, K
    Nishino, K
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2003, 46 (01) : 175 - 180
  • [44] Experimental study of frost growth characteristics on surface of finned-tube heat exchangers
    Zhang L.
    Guo X.
    Xue J.
    Huagong Xuebao/CIESC Journal, 2018, 69 : 186 - 192
  • [45] EXPERIMENTAL AND NUMERICAL STUDY OF HEAT TRANSFER OVER A FINNED ELLIPTICAL FLAT TUBE FITTED WITH LONGITUDINAL VORTEX GENERATORS ON THE RECTANGULAR FIN SURFACE
    Li, Li
    Du, Xiaoze
    Zhang, Yuwen
    Xu, Chao
    Yang, Lijun
    Yang, Yongping
    JOURNAL OF ENHANCED HEAT TRANSFER, 2013, 20 (05) : 427 - 441
  • [46] Parametric Evaluation of Condensate Water Yield from Plain Finned Tube Heat Exchangers in Atmospheric Water Generation
    Siddiqui, Mubashir
    Azam, Muhammad Anique
    Ali, Hafiz Muhammad
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2022, 47 (12) : 16251 - 16271
  • [47] Parametric Evaluation of Condensate Water Yield from Plain Finned Tube Heat Exchangers in Atmospheric Water Generation
    Mubashir Siddiqui
    Muhammad Anique Azam
    Hafiz Muhammad Ali
    Arabian Journal for Science and Engineering, 2022, 47 : 16251 - 16271
  • [48] Air side heat transfer coefficient in plate finned tube heat exchangers
    Mihailovic, Milos
    Milovancevic, Uros
    Genic, Srbislav
    Jacimovic, Branislav
    Otovic, Milena
    Kolendic, Petar
    EXPERIMENTAL HEAT TRANSFER, 2020, 33 (04) : 388 - 399
  • [49] An experimental study in determining the local heat transfer coefficients for the plate finned-tube heat exchangers
    Huang, Cheng-Hung
    Yuan, I-Cha
    Ay, Herchang
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (21-22) : 4883 - 4893
  • [50] Parametric study and field synergy principle analysis of H-type finned tube bank with 10 rows
    Jin, Yu
    Tang, Gui-Hua
    He, Ya-Ling
    Tao, Wen-Quan
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 60 : 241 - 251