Parametric study on rectangular finned elliptical tube heat exchangers with the increase of number of rows

被引:13
|
作者
Zhao, Lanping [1 ]
Wang, Renjie [1 ]
Gu, Xitao [1 ]
Yang, Zhigang [2 ,3 ]
机构
[1] Tongji Univ, Sch Mech Engn, Inst Refrigerat & Cryogen Engn, Shanghai, Peoples R China
[2] Shanghai Key Lab Vehicle Aerodynam & Vehicle Ther, Shanghai, Peoples R China
[3] Beijing Aeronaut Sci & Technol Res Inst, Beijing, Peoples R China
关键词
Rectangular finned elliptical tube heat exchanger (RFETHX); Airside thermal-hydraulic characteristics; Number of rows; Interaction effect; Contribution ratio; Response surface method (RSM); THERMAL-HYDRAULIC CHARACTERISTICS; AIR-SIDE PERFORMANCE; PLATE-FIN; FRICTION CHARACTERISTICS; VORTEX GENERATORS; TAGUCHI METHOD; NUMERICAL-ANALYSIS; DESIGN PARAMETERS; DELTA-WINGLETS; OPTIMIZATION;
D O I
10.1016/j.ijheatmasstransfer.2018.05.036
中图分类号
O414.1 [热力学];
学科分类号
摘要
The objective of this study is to investigate the performance of rectangular finned elliptical tube heat exchangers (RFETHXs) of low number of rows (N) in turbulent region, with an emphasis on the characteristics with the increase of N. Using 3D numerical simulations based on the validated standard k-epsilon turbulence model, the average thermal-hydraulic characteristics of each row as well as the overall performance along with N are investigated. Then the contribution of each structural factor and the interaction effects between various parameters on the performance are revealed using variance analysis in 4 sub-row-regions. The most significant interaction effect on the performance evaluation criterion (PEC) between structural parameters is confirmed using Response Surface Method (RSM). It is observed that, for the RFETHXs with N > 2, the heat transfer coefficient of the second row of fins is the largest, while those of the first and the last rows remain the smallest two. A 2-row RFETHX has better performance compared to the RFETHXs with larger N. In most cases, the flow and heat transfer of RFETHXs enters fully developed state from the fifth row, but as the transverse tube pitch (P-t) increases or the fin thickness declines, such state is postponed to deeper rows. It demonstrates that significant impact of N on PEC exists in the sub-row-range of 2-3. With the incline of N, the effect of fin pitch (F-p) to j and f decreases while that of P-t increases, and the interaction effect between P-t and F-p to j and PEC becomes more pronounced. This interaction reduces with the increase of frontal velocity. The reason for such interaction is discussed. At last, results of RMS analysis further depict that the interaction effect between P-t and F-p on PEC of a 6-row RFETHX is more significant than that of a 2-row RFETHX. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:871 / 893
页数:23
相关论文
共 50 条
  • [1] The effect of the number of tube rows on heat, mass and momentum transfer in flat-plate finned tube heat exchangers
    Halici, F
    Taymaz, I
    Gündüz, M
    ENERGY, 2001, 26 (11) : 963 - 972
  • [2] The effect of the number of tube rows on heat, mass and momentum transfer in flat-plate finned tube heat exchangers
    Halc, Fethi
    Taymaz, Imdat
    Gündüz, Mehmet
    1600, Elsevier Ltd (26):
  • [3] Numerical Study of Flow Over Annular Elliptical Finned Tube Heat Exchangers
    Nemati, H.
    Samivand, S.
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2016, 41 (11) : 4625 - 4634
  • [4] Numerical Study of Flow Over Annular Elliptical Finned Tube Heat Exchangers
    H. Nemati
    S. Samivand
    Arabian Journal for Science and Engineering, 2016, 41 : 4625 - 4634
  • [5] Aero-thermal behavior and performance optimization of rectangular finned elliptical heat exchangers with different tube arrangements
    Zhao, Lanping
    Wang, Bei
    Wang, Renjie
    Yang, Zhigang
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 133 : 1196 - 1218
  • [6] Parametric study and optimization of louver finned-tube heat exchangers by Taguchi method
    Hsieh, Ching-Tsun
    Jang, Jiin-Yuh
    APPLIED THERMAL ENGINEERING, 2012, 42 : 101 - 110
  • [7] Parametric study and optimization of H-type finned tube heat exchangers using Taguchi method
    Wang, Heng
    Liu, Ying-wen
    Yang, Peng
    Wu, Ren-jie
    He, Ya-ling
    APPLIED THERMAL ENGINEERING, 2016, 103 : 128 - 138
  • [8] Parametric Study on Thermal-Hydraulic Characteristics of H-Type Finned Tube Heat Exchangers
    Feng, Yong-Shi
    Liang, Cai
    Wu, Xin
    Fang, Hui
    JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2023, 37 (02) : 365 - 381
  • [9] Heat capacity of finned-tube heat exchangers
    Ebeling, Norbert
    Schmidt, Klaus Gerhard
    Brennstoff-Waerme-Kraft, 50 (5/6): : 64 - 66
  • [10] Heat capacity of finned-tube heat exchangers
    Ebeling, N
    Schmidt, KG
    BRENNSTOFF-WARME-KRAFT, 1998, 50 (5-6): : 64 - +