Extended Stable Boundary of LCL-Filtered Grid-Connected Inverter Based on An Improved Grid-Voltage Feedforward Control

被引:0
|
作者
Lu, Minghui [1 ]
Xin, Zhen [1 ]
Wang, Xiongfei [1 ]
Beres, Remus Narcis [1 ]
Blaabjerg, Frede [1 ]
机构
[1] Aalborg Univ, Dept Energy Technol, Pontoppidanstr 101, DK-9220 Aalborg, Denmark
来源
2016 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE) | 2016年
基金
欧洲研究理事会;
关键词
Grid-connected inverters; LCL-filter; improved grid-voltage feedforward scheme;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
For the LCL-filtered grid-connected inverter, it has been reported that the digital time delays will narrow the stable region of current control loop when the inverter-side current is used for implementing the feedback control. A sufficient stable condition is that the filter resonance frequency should be designed under one-sixth of sampling frequency. However, the low resonance frequency leads to a comparatively large filter inductance or/and capacitance. To extend the stable boundary to the region above f(s)/6, this paper proposes a novel voltage feedforward scheme for the LCL-filtered inverter. Theoretical analysis is then provided to validate its feasibility and stability. Compared to other widely used active damping strategies, no extra sensors are needed because the filter capacitor voltage, which is used for voltage feedforward control, is also sampled for phase-locked loop in this paper. Simulations and experimental results are provided for verifying the theoretical analyses.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Direct Grid Current Control of LCL-Filtered Grid-Connected Inverter Mitigating Grid Voltage Disturbance
    Jia, Yaoqin
    Zhao, Jiqian
    Fu, Xiaowei
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (03) : 1532 - 1541
  • [2] Grid-Voltage Feedforward Based Control for GridConnected LCL-Filtered Inverter with High Robustness and Low Grid Current Distortion in Weak Grid
    Xu, Jinming
    Qian, Qiang
    Xie, Shaojun
    Zhang, Binfeng
    APEC 2016 31ST ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, 2016, : 1919 - 1925
  • [3] Improved control strategy with grid-voltage feedforward for LCL-filter-based inverter connected to weak grid
    Xu, Jinming
    Xie, Shaojun
    Tang, Ting
    IET POWER ELECTRONICS, 2014, 7 (10) : 2660 - 2671
  • [4] Hybrid Model Predictive Current and Voltage Control for LCL-Filtered Grid-Connected Inverter
    Xue, Cheng
    Zhou, Dehong
    Li, Yunwei
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2021, 9 (05) : 5747 - 5760
  • [5] Evaluations of current control in weak grid case for grid-connected LCL-filtered inverter
    Xu, Jinming
    Xie, Shaojun
    Tang, Ting
    IET POWER ELECTRONICS, 2013, 6 (02) : 227 - 234
  • [6] Active damping of LCL-Filtered Grid-Connected inverter based on parallel feedforward compensation strategy
    Khan, Danish
    Zhu, Keping
    Hu, Pengfei
    Waseem, Muhammad
    Ahmed, Emad M.
    Lin, Zhenzhi
    AIN SHAMS ENGINEERING JOURNAL, 2023, 14 (03)
  • [7] Observer-based Control for Grid-connected LCL-filtered Inverter with Only Grid Current Feedback
    Lai, Ngoc-Bao
    Kim, Kyeong-Hwa
    2ND INTERNATIONAL CONFERENCE ON APPLIED MECHANICS, ELECTRONICS AND MECHATRONICS ENGINEERING (AMEME), 2017, : 167 - 170
  • [8] Robust EMPC-Based Frequency-Adaptive Grid Voltage Sensorless Control for an LCL-Filtered Grid-Connected Inverter
    Kim, Yubin
    Tran, Thuy Vi
    Kim, Kyeong-Hwa
    ELECTRONICS, 2024, 13 (05)
  • [9] Voltage feedforward control of lcl grid-connected inverter based on virtual inductor
    Yang, Xingwu
    Wang, Tao
    Xu, Yiming
    Yang, Shuai
    Li, Hao
    Mi, Yang
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2020, 41 (11): : 56 - 63
  • [10] Active Damping-Based Control for Grid-Connected LCL-Filtered Inverter With Capacitor Voltage Inertial Feedback
    Huang, Yashen
    Wang, Haining
    Zhang, Xiaoan
    Gao, Liangchun
    2016 IEEE 8TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (IPEMC-ECCE ASIA), 2016,