摘要
For grid-connected inverters, switching harmonics can be effectively attenuated through an LCL-type filter. In order to suppress resonance and guarantee good performance, many strategies (e. g. active damping (AD), harmonic resonant control, repetitive control and grid feedforward) have been proposed. However, the wide variation of grid impedance value challenges system stability in practical applications. The aforementioned methods need to be investigated. This study evaluates the applicability of each part of the overall control in a weak grid case with the use of a stability criterion. It has been demonstrated that the feedback-based AD control can work well in a wide range of grid conditions. However, the resonant and repetitive control methods meet constraints. The grid feedforward method brings in an extra positive feedback path, and consequently results in high harmonics or even instability. Finally, a recommendation for system design has been presented. Simulations and experiments have been provided to verify the analysis.
引用
收藏
页码:227 / 234
页数:8
相关论文
共 50 条
  • [1] Direct Grid Current Control of LCL-Filtered Grid-Connected Inverter Mitigating Grid Voltage Disturbance
    Jia, Yaoqin
    Zhao, Jiqian
    Fu, Xiaowei
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (03) : 1532 - 1541
  • [2] Observer-based Control for Grid-connected LCL-filtered Inverter with Only Grid Current Feedback
    Lai, Ngoc-Bao
    Kim, Kyeong-Hwa
    [J]. 2ND INTERNATIONAL CONFERENCE ON APPLIED MECHANICS, ELECTRONICS AND MECHATRONICS ENGINEERING (AMEME), 2017, : 167 - 170
  • [3] Hybrid Model Predictive Current and Voltage Control for LCL-Filtered Grid-Connected Inverter
    Xue, Cheng
    Zhou, Dehong
    Li, Yunwei
    [J]. IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2021, 9 (05) : 5747 - 5760
  • [4] A Control Parameters Design Method With Multi-Constrains for an LCL-Filtered Grid-Connected Inverter in a Weak Grid
    Wu, Fuyun
    Sun, Zhuang
    Xu, Weiji
    Li, Zhizhou
    Lyu, Jianguo
    [J]. FRONTIERS IN ENERGY RESEARCH, 2022, 9
  • [5] A Control Parameters Design Method With Multi-Constrains for an LCL-Filtered Grid-Connected Inverter in a Weak Grid
    Wu, Fuyun
    Sun, Zhuang
    Xu, Weiji
    Li, Zhizhou
    Lyu, Jianguo
    [J]. Frontiers in Energy Research, 2022, 9
  • [6] Stability Assessment of Current Controller with Harmonic Compensator for LCL-Filtered Grid-Connected Inverter under Distorted Weak Grid
    Yoon, Seung-Jin
    Tran, Thuy Vi
    Kim, Kyeong-Hwa
    [J]. APPLIED SCIENCES-BASEL, 2021, 11 (01): : 1 - 32
  • [7] Optimization of Weighted Current Control for Grid-Connected LCL-Filtered Inverters
    Xu, Jinming
    Xie, Shaojun
    [J]. 2013 IEEE ECCE ASIA DOWNUNDER (ECCE ASIA), 2013, : 1170 - 1175
  • [8] Improved Inverter-Side Current Control for Grid-Connected LCL-Filtered Inverter with Low Grid Current Distortion and High Robustness
    Xu, Jinming
    Zhang, Binfeng
    Xiao, Lan
    Qian, Qiang
    Xie, Shaojun
    [J]. 2017 IEEE SOUTHERN POWER ELECTRONICS CONFERENCE (SPEC), 2017, : 561 - 566
  • [9] Active Damping-Based Control for Grid-Connected LCL-Filtered Inverter With Injected Grid Current Feedback Only
    Xu, Jinming
    Xie, Shaojun
    Tang, Ting
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2014, 61 (09) : 4746 - 4758
  • [10] Mitigation of Grid-Current Distortion for LCL-Filtered Grid-Connected Voltage-Source Inverter with Inverter-Side Current Control
    Xin, Zhen
    Mattavelli, Paolo
    Yao, Wenli
    Blaabjerg, Frede
    Poh Chiang Loh
    [J]. 2017 IEEE 3RD INTERNATIONAL FUTURE ENERGY ELECTRONICS CONFERENCE AND ECCE ASIA (IFEEC 2017-ECCE ASIA), 2017, : 471 - 476