Comparison of visual results and optical quality of two presbyopia-correcting intraocular lenses: TECNIS symfony versus TECNIS synergy

被引:15
|
作者
Shin, Da Eun [1 ]
Lee, Hun [2 ]
Kim, Tae-Im [3 ]
Koh, Kyungmin [1 ]
机构
[1] Konyang Univ, Kims Eye Hosp, Dept Opthalmol, Coll Med, 136 Youngshinro, Seoul 07301, South Korea
[2] Univ Ulsan, Asan Med Ctr, Dept Ophthalmol, Coll Med, Seoul, South Korea
[3] Yonsei Univ, Severance Eye Hosp, Dept Opthalmol, Coll Med, Seoul, South Korea
关键词
Defocus curve; extended depth of focus; extended range of vision; presbyopia; presbyopia-correcting intraocular lens; DEPTH-OF-FOCUS; EXTENDED DEPTH; PATIENT SATISFACTION; CLINICAL-OUTCOMES; IMPLANTATION; RANGE; PERFORMANCE; IOL;
D O I
10.1177/11206721221093024
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: This study compared the extended depth of focus (EDOF) intraocular lens (IOL) (ZXR00; Tecnis (R) Symfony (R), Johnson & Johnson Vision, Santa Ana, CA, USA) and a new presbyopia-correcting IOL that combines EDOF and multifocal profiles (ZFR00; Tecnis (R) Synergy (R), Johnson & Johnson Vision, Santa Ana, CA, USA) with the same material. Methods: The medical records of patients undergoing cataract surgery with ZXR00 or ZFR00 implantation between March 2021 and July 2021 and with the data available for the 3-month visit were reviewed. The uncorrected near, intermediate, and distance visual acuity (VA), corrected distance VA, defocus curves, refractive errors (RE), optical quality parameters, and patient-reported visual performance parameters were the main outcome measures. Results: Among the twenty-three enrolled patients, twelve patients (21 eyes) received ZXR00 and nine patients (17 eyes) received ZFR00. The mean age of the patients was 59.6 +/- 10.6 (range: 49 to 70) and 65.2 +/- 8.2 (range: 45 to 82) years in ZXR00 and ZFR00 groups, respectively, without significant difference. There was not a significant difference between the two groups in terms of baseline parameters and postoperative RE. The ZFR00 group showed markedly superior intermediate and near VA (p < 0.001 for all) at 3 months postoperatively. In terms of optical quality, ZXR00 was significantly better than ZFR00 (p < 0.001). Conclusions: Both IOLs had comparable distance VA. ZFR00 IOL was superior for intermediate and near visual acuity, but ZXR00 IOL was better for optical quality. Research with more participants is needed to support this finding.
引用
收藏
页码:3461 / 3469
页数:9
相关论文
共 48 条
  • [21] Objective evaluation of through-focus optical performance of presbyopia-correcting intraocular lenses using an optical bench system
    Kim, Myoung Joon
    Zheleznyak, Len
    MacRae, Scott
    Tchah, Hungwon
    Yoon, Geunyoung
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (07): : 1305 - 1312
  • [22] Comparison of Tecnis 1-piece multifocal versus monofocal intraocular lenses: A prospective clinical multicentre study
    Auffarth, G. U.
    Rabsilber, T. M.
    Mannsfeld, A.
    Villalba, J. A.
    Limberger, I-J
    Holzer, M. P.
    ACTA OPHTHALMOLOGICA, 2010, 88 : 50 - 50
  • [23] A comparative study of two presbyopia-correcting intraocular lenses combining bifocal and extended depth-of-focus profiles
    Kim, Jeongmin
    Kim, Tae-im
    Seo, Kyoung Yul
    Tchah, Hungwon
    Koh, Kyungmin
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [24] Comparison of visual and optical quality of monofocal versus multifocal intraocular lenses
    Altemir-Gomez, Irene
    Millan, Maria S.
    Vega, Fidel
    Bartol-Puyal, Francisco
    Gimenez-Calvo, Galadriel
    Larrosa, Jose M.
    Polo, Vicente
    Pablo, Luis E.
    Garcia-Martin, Elena
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2020, 30 (02) : 299 - 306
  • [25] Comparison of the visual performance between Oculentis MF30 and Tecnis ZMB00 multifocal intraocular lenses
    Ye, Lingying
    Chen, Tianyu
    Hu, Zhixiang
    Yang, Qingwen
    Su, Qiudong
    Li, Jin
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (02)
  • [26] Visual acuity and contrast sensitivity comparison between Tecnis and AcrySof SA60AT intraocular lenses: A multicenter randomized study
    Bellucci, R
    Scialdone, A
    Buratto, L
    Morselli, S
    Chierego, C
    Criscuoli, A
    Moretti, G
    Piers, P
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (04): : 712 - 717
  • [27] Visual and optical performance of the akreos adapt advanced optics and tecnis Z9000 intraocular lenses - Swedish multicenter study
    Johansson, Bjoern
    Sundelin, Staffan
    Wikberg-Matsson, Anna
    Unsbo, Peter
    Behndig, Anders
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (09): : 1565 - 1572
  • [28] Comparison of Anticipated Versus Actual Postoperative Refractive Errors for Akreos A060 and Tecnis ZCBOO Intraocular Lenses in a Normal Cataract Population
    Markakis, George Aristotle
    Apostolakis, Nicholas Aristotle
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [29] Visual outcomes and patient satisfaction after implantations of three types of presbyopia-correcting intraocular lenses that have undergone corneal refractive surgery
    Ni, Shuang
    Zhuo, Baoxian
    Cai, Lei
    Wang, Min
    Shen, Jiying
    Zhang, Limei
    Shen, Wenqian
    Guo, Haike
    Yang, Jin
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [30] Comparison of Barrett TK Universal II and Barrett Universal II TCRP Formulas in Power Calculations for 3 Presbyopia-Correcting Intraocular Lenses
    Li, Qingchen
    Liu, Xinyi
    Yang, Jiasong
    Dai, Yumeng
    Li, Wensheng
    CLINICAL OPHTHALMOLOGY, 2024, 18 : 1457 - 1465