Effect of operating conditions on the physical and chemical CO2 absorption through the PVDF hollow fiber membrane contactor

被引:139
|
作者
Mansourizadeh, A. [1 ]
Ismail, A. F. [1 ]
Matsuura, T. [2 ]
机构
[1] Univ Teknol Malaysia, Adv Membrane Technol Res Ctr AMTEC, Skudai 81310, Johor, Malaysia
[2] Univ Ottawa, Dept Chem & Biol Engn, Ind Membrane Res Inst, Ottawa, ON K1N 6N5, Canada
关键词
Porous PVDF hollow fiber membrane; CO2; absorption; Operating parameters; MASS-TRANSFER; CARBON-DIOXIDE; REMOVAL; SEPARATION; CAPTURE; LIQUIDS;
D O I
10.1016/j.memsci.2010.02.054
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Porous polyvinylidene fluoride (PVDF) hollow fiber membranes were fabricated via a wet phase-inversion process and used in the gas-liquid membrane contactor for physical and chemical CO2 absorption. Effect of different operating parameters such as absorbent temperature. CO2 pressure, absorbent flow rate and long-term operation on the CO2 flux of the membrane were investigated. The characterization results showed that the prepared membrane possess small pore size with high surface porosity and wetting resistance, which are favorable for gas absorption application. Results of CO2 absorption experiments revealed that in case of physical absorption with distilled water, CO2 solubility was the key parameter which significantly affected the membrane CO2 flux. A significant increase in the CO2 flux was observed by increasing CO2 pressure and decreasing the absorbent temperature. However, in case of chemical absorption with NaOH (1 M), the reaction rate was dominant, where the CO2 flux was significantly increased by increasing the absorbent temperature. It was also found that when the liquid contacted the outer skin layer of the hollow fiber membrane, the operation was stable at the same gas and liquid pressure without bubble formation in the liquid phase. In addition, the results of long-term study demonstrated that the membrane performance was maintained constant for long-term operation. The initial flux reduction was found to be about 30% within the 23 h of physical absorption, and 20% of gradual reduction within 80 h of chemical absorption. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:192 / 200
页数:9
相关论文
共 50 条
  • [31] Modeling of CO2 Stripping in a Hollow Fiber Membrane Contactor for CO2 Capture
    Wang, Zhen
    Fang, Mengxiang
    Yu, Hai
    Ma, Qinhui
    Luo, Zhongyang
    ENERGY & FUELS, 2013, 27 (11) : 6887 - 6898
  • [32] Enhanced CO2 separation using aqueous amine blends and nanofluids in PVDF hollow fiber membrane contactor
    Rehman, Zia Ur
    Ahmad, Shakil
    Muhammad, Amir
    Ghasem, Nayef
    Al-Marzouqi, Mohamed
    Younas, Mohammad
    Rezakazemi, Mashallah
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2025, 215 : 170 - 179
  • [33] Biocatalytic PVDF composite hollow fiber membranes for CO2 removal in gas-liquid membrane contactor
    Xu, Yilin
    Lin, Yuqing
    Chew, Nick Guan Pin
    Malde, Chandresh
    Wang, Rong
    JOURNAL OF MEMBRANE SCIENCE, 2019, 572 : 532 - 544
  • [34] Experimental and theoretical analyses of effects of membrane properties on CO2 absorption performance of a hollow fiber membrane contactor
    Takahashi, Nobuhide
    Mano, Hiroshi
    Okabe, Kazuhiro
    Nakamura, Miho
    Fujioka, Yuichi
    Mimura, Tomio
    Yagi, Yasuyuki
    KAGAKU KOGAKU RONBUNSHU, 2008, 34 (01) : 76 - 84
  • [35] Hollow fiber membrane contactor hybrid system for CO2 recovery
    Lee, KH
    Yeon, SH
    Sea, B
    Park, YI
    CARBON DIOXIDE UTILIZATION FOR GLOBAL SUSTAINABILITY, 2004, 153 : 423 - 428
  • [36] Effect of bore fluid composition on structure and performance of asymmetric polysulfone hollow fiber membrane contactor for CO2 absorption
    Rahbari-sisakht, M.
    Ismail, A. F.
    Matsuura, T.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2012, 88 : 99 - 106
  • [37] Effect of novel surface modifying macromolecules on morphology and performance of Polysulfone hollow fiber membrane contactor for CO2 absorption
    Rahbari-Sisakht, M.
    Ismail, A. F.
    Rana, D.
    Matsuura, T.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2012, 99 : 61 - 68
  • [38] Effect of non-solvent additive concentration on CO2 absorption performance of polyvinylidenefluoride hollow fiber membrane contactor
    Pang, Honglei
    Gong, Huijuan
    Du, Mengfan
    Shen, Qi
    Chen, Zezhi
    SEPARATION AND PURIFICATION TECHNOLOGY, 2018, 191 : 38 - 47
  • [39] Effect of fiber packing density on physical CO2 absorption performance in gas-liquid membrane contactor
    Naim, R.
    Ismail, A. F.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2013, 115 : 152 - 157
  • [40] Absorption of CO2 Form Natural Gas via Gas-liquid PVDF Hollow Fiber Membrane Contactor and Potassium Glycinate as Solvent
    Ghasem, Nayef
    Al-Marzouqi, Mohamed
    Rahim, Nihmiya Abdul
    JURNAL TEKNOLOGI, 2014, 69 (09):