The National Cardiovascular Center electrohydraulic total artificial heart and ventricular assist device systems: Current status of development

被引:13
|
作者
Tatsumi, E
Taenaka, Y
Homma, A
Nishinaka, T
Takewa, Y
Tsukiya, T
Ohnishi, H
Oshikawa, M
Shirakawa, Y
Kakuta, Y
Shioya, K
Katagiri, N
Mizuno, T
Kamimura, T
Takano, H
Tsukahara, K
Tsuchimoto, K
Wakui, H
Yamaguchi, H
机构
[1] Natl Cardiovasc Ctr, Res Inst, Dept Artificial Organs, Suita, Osaka 5658565, Japan
[2] Aisin Cosmos Res & Dev Co Ltd, Kariya, Aichi 448, Japan
关键词
D O I
10.1097/01.MAT.0000065374.83106.FE
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Electrohydraulic total artificial heart (EHTAH) and electrohydraulic ventricular assist device (EHVAD) systems have been developed in our institute. The EHTAH system comprises a pumping unit consisting of blood pumps and an actuator, as well as an electronic unit consisting of an internal controller, internal and external batteries, and transcutaneous energy transfer (TET) and optical telemetry (TOT) subunits. The actuator, placed outside the pericardial space, reciprocates and delivers hydraulic silicone oil to the alternate blood pumps through a pair of flexible oil conduits. The pumping unit with an external controller was implanted in 10 calves as small as 55 kg. Two animals survived for more than 12 weeks in a good general condition. The assumed cardiac output ranged between 6 and 10 L/min, the power consumption was 12-18 W, and the energy efficiency was estimated to be 9-11%. initial implantation of subtotal system including electronic units was further conducted in another calf weighing 73 kg. It survived for 3 days with a completely tether free system. The EHVAD system is developed by using the left blood pump and the actuator of the EHTAH, which were packaged in a compact metal casing with a compliance chamber. In vitro testing demonstrated maximum output more than 9 L/min and more than 13% maximum efficiency. The initial animal testing lasted for 25 days. These results indicate that our EHTAH and EHVAD have the potential to be totally implantable systems.
引用
下载
收藏
页码:243 / 249
页数:7
相关论文
共 50 条
  • [31] HVAD CONTINUOUS FLOW VENTRICULAR ASSIST DEVICE FOR ISCHEMIC VENTRICULAR SEPTAL RUPTURE - NO NEED FOR A TOTAL ARTIFICIAL HEART!
    Bernhardt, A.
    Reichenspurner, H.
    Deuse, T.
    TRANSPLANT INTERNATIONAL, 2014, 27 : 11 - 11
  • [32] Use of Berlin Heart ventricular assist devices as a total artificial heart
    Kato, Hideyuki
    Gandhi, Sanjiv K.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 156 (02): : 743 - 745
  • [33] Autonomic nerve function with an artificial heart and ventricular assist device
    Yambe T.
    Nanka S.-S.
    Tanaka A.
    Hashimoto H.
    Yoshizawa M.
    Tabayashi K.-I.
    Takeda H.
    Nitta S.-I.
    Journal of Artificial Organs, 2001, 4 (2) : 83 - 87
  • [34] Current Status of the MicroMed DeBakey Noon Ventricular Assist Device
    Noon, George P.
    Loebe, Matthias
    TEXAS HEART INSTITUTE JOURNAL, 2010, 37 (06) : 652 - 653
  • [35] Current status and future directions in pediatric ventricular assist device
    Huang, Xu
    Shen, Yi
    Liu, Yiwei
    Hao, Zhang
    HEART FAILURE REVIEWS, 2024, 29 (04) : 769 - 784
  • [36] Current status of ventricular assistance and the artificial heart
    Salazar, Leonardo
    Ortiz Cordoba, Angelica Lucero
    Ballesteros Trillos, Juliana
    Garcia Rueda, Karen Andrea
    REVISTA MEDICA CLINICA LAS CONDES, 2022, 33 (03): : 275 - 281
  • [37] DEVELOPMENT OF THE PHYSIOLOGICAL CONTROL SCHEME FOR AN ELECTROHYDRAULIC TOTAL ARTIFICIAL-HEART
    KHANWILKAR, PS
    CRUMP, KR
    BEARNSON, GB
    SMITH, JK
    OLSEN, DB
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 149 - 150
  • [38] Development of an Electrohydraulic Total Artificial Heart System: Improvement of Pump Unit
    Homma, Akihiko
    Taenaka, Yoshiyuki
    Tatsumi, Eisuke
    Takewa, Yoshiaki
    Mizuno, Toshihide
    Shioya, Kyoko
    Lee, Hwan Sung
    Tsukiya, Tomonori
    Kakuta, Yukihide
    Katagiri, Nobumasa
    Nishinaka, Tomohiro
    Koshiji, Kohji
    ELECTRONICS AND COMMUNICATIONS IN JAPAN, 2010, 93 (09) : 34 - 46
  • [39] Development of an electrohydraulic total artificial heart system - Improvement of the pump unit
    Advanced Medical Engineering Center, Research Institute, National Cardio Vascular Center, 5-7-1 Fujishiro-dai, Suita, Osaka 565-8565, Japan
    不详
    不详
    IEEJ Trans. Electron. Inf. Syst., 2008, 6 (943-952+17):
  • [40] A Simple Cardiovascular System Model for Ventricular Assist Device Development
    Yu, Yih-Choung
    Zhang, Xiaobin
    2009 35TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2009, : 143 - 144