Corneal cell density measurement in vivo by scanning slit confocal microscopy: Method and validation

被引:37
|
作者
Popper, M
Morgado, AM
Quadrado, MJ
Van Best, JA
机构
[1] Univ Coimbra, Dept Ophthalmol, Inst Biomed Res Light & Image, Coimbra, Portugal
[2] Univ Coimbra, Dept Instrumentat, Inst Biomed Res Light & Image, Coimbra, Portugal
[3] Univ Coimbra, Dept Phys, Coimbra, Portugal
[4] Semmelweiss Univ, Dept Ophthalmol 1, Budapest, Hungary
关键词
corneal layers; cell density; scanning slit confocal microscope; density validation;
D O I
10.1159/000081207
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Method and validation of a technique to quantify cell density in vivo in 6 corneal layers with a scanning slit confocal microscope (SSCM). Method: A confocal image of a small volume in a corneal layer is registered on videotape. Cells or nuclei according to a layer classification are counted manually using an unbiased frame. Surface cell density is calculated from an image on the screen, and volumetric density is obtained using stereological methods. Results: Image distortion on the screen is less than 3%. The classification of a cell layer is verified by determining the position of the measurement volume in the cornea. Validation of density measurements is performed by comparing confocal results with those obtained by histology. The difference between the two methods varies from -24.1% ( posterior stroma) to +16.4% ( basal layer). Intersession and intrasession repeatability are 8.3 and 5.8%, respectively. The cell density (mean +/- SD) in 20 healthy controls in the superficial, basal and endothelial layers was 759 +/- 162, 5,817 +/- 632 and 2,743 +/- 285 cells.mm(-2) (surface), and in the anterior, mid and posterior stroma 28,616 +/- 3,081, 19,578 +/- 4,421 and 26,073 +/- 5,962 cells.mm(-3) (volumetric). These results are in accordance with those of other investigators. Conclusions: The SSCM can produce repeatable quantitative measurements of corneal cell density in conscious humans. Copyright (C) 2004 S. Karger AG, Basel.
引用
收藏
页码:270 / 276
页数:7
相关论文
共 50 条
  • [21] Corneal In Vivo Confocal Scanning Laser Microscopy in Patients with Atopic Keratoconjunctivitis
    Hu, Yiqian
    Matsumoto, Yukihiro
    Adan, Enrique Sato
    Dogru, Murat
    Fukagawa, Kazumi
    Tsubota, Kazuo
    Fujishima, Hiroshi
    OPHTHALMOLOGY, 2008, 115 (11) : 2004 - 2012
  • [22] Scanning slit confocal microscopy of crystalline keratitis
    Auran, JD
    Shayegani, A
    Donnenfeld, ED
    Perry, HD
    Grossman, G
    Zaidman, GW
    Konariek, JP
    Koester, CJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 4709 - 4709
  • [23] Scanning slit confocal microscopy of fungal keratitis
    Florakis, GJ
    Moazami, G
    Schubert, H
    Koester, CJ
    Auran, JD
    ARCHIVES OF OPHTHALMOLOGY, 1997, 115 (11) : 1461 - 1463
  • [24] Evaluation of the Corneal Layers in Meibomian-Gland-Dysfunction-Related Dry Eye by In Vivo Slit-Scanning Confocal Microscopy
    Azizi, Sedat
    Ucak, Turgay
    Yasar, Ibrahim
    Karakurt, Yucel
    Erdogan, Erkan
    Salman, Ilknur
    SEMINARS IN OPHTHALMOLOGY, 2017, 32 (03) : 377 - 383
  • [25] In Vivo Confocal Microscopy Observation of Cell and Nerve Density in Different Corneal Regions with Monocular Pterygium
    Shen, Yun-Zhi
    Xu, Mi
    Sun, Song
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [26] Regional Variations in Corneal Epithelial Cell Density and Morphology Assessed Using In Vivo Confocal Microscopy
    Bhattacharya, Pradipta
    Edwards, Katie
    Schmid, Katrina L.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2024, 50 (04): : 163 - 170
  • [27] Diabetes and corneal cell densities in humans by in vivo confocal microscopy
    Quadrado, Maria Joao
    Popper, Monika
    Morgado, Antonio Miguel
    Murta, Joaquim Neto
    Van Best, Jaap A.
    CORNEA, 2006, 25 (07) : 761 - 768
  • [28] REAL-TIME SCANNING SLIT CONFOCAL MICROSCOPY OF THE IN-VIVO HUMAN CORNEA
    MASTERS, BR
    THAER, AA
    APPLIED OPTICS, 1994, 33 (04) : 695 - 701
  • [29] Diagnosing and monitoring the characteristics of Acanthamoeba keratitis using slit scanning and laser scanning in vivo confocal microscopy
    Curro-Tafili, K.
    Verbraak, F. D.
    de Vries, R.
    van Nispen, R. M. A.
    Ghyczy, E. A. E.
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2024, 44 (01) : 131 - 152
  • [30] Comparison of in vivo confocal microscopy of human cornea by white light scanning slit and laser scanning systems
    Szaflik, Jacek P.
    CORNEA, 2007, 26 (04) : 438 - 445