Early Minimally Invasive Percutaneous Fixation of Displaced Intra-Articular Calcaneal Fractures With a Percutaneous Angle Stable Device

被引:35
|
作者
Battaglia, Alberto [1 ]
Catania, Pompeo [1 ]
Gumina, Stefano [2 ]
Carbone, Stefano [2 ]
机构
[1] San Giovanni Addolorata Hosp, Dept Orthopaed & Traumatol, Rome, Italy
[2] Univ Roma La Sapienza, Dept Orthopaed & Traumatol, I-00185 Rome, Italy
来源
JOURNAL OF FOOT & ANKLE SURGERY | 2015年 / 54卷 / 01期
关键词
calcaneal fracture; compartmental syndrome; drainage effect; minimally invasive reduction; percutaneous fixation; OPERATIVE TREATMENT; OSTEOSYNTHESIS; COMPLICATIONS; REDUCTION; FOOT;
D O I
10.1053/j.jfas.2014.08.021
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The Minimally Invasive Reduction and Osteosynthesis System (R) (MIROS) is a percutaneous angle stable device for the treatment of fractures. The aim of the present study was to evaluate the clinical and radiographic results of an early minimally invasive osteosynthesis with the MIROS device. A total of 40 consecutive patients were treated for an intra-articular fracture of the calcaneus. We evaluated the clinical and radiographic outcomes after treatment of intra-articular calcaneal fractures with the MIROS hardware. Soft tissue damage was noted. The patients completed the American Orthopaedic Foot and Ankle Society survey at 12 and 24 months and underwent radiologic evaluations. A statistically significant association between the American Orthopaedic Foot and Ankle Society score and type of soft tissue lesion. A Sanders type II, III, and IV fracture was found in 15, 20, and 15 of 50 fractures, respectively. Postoperatively, restoration of the posterior facet was reached in 13 of 15, 18 of 20, and 11 of 15 with a type II, III, and IV fracture, respectively. The American Orthopaedic Foot and Ankle Society scale mean score was 85 at the final follow-up visit. No significant association was found between the score and the preoperative variables (p > .09), although patients with bilateral fractures had a significantly lower score. The MIROS device for early treatment of intra-articular calcaneus fractures resulted in excellent clinic and radiologic results. The standardized technique we have reported, with the elastic wires acting as a girder for the fractured and displace subtalar joint and the collapsed lateral calcaneal wall, has permitted early weightbearing with positive stimuli for the bone healing. The drainage effect of the percutaneous wires likely prevented compartment syndrome when applied within the first hours after the trauma. (C) 2015 by the American College of Foot and Ankle Surgeons. All rights reserved.
引用
收藏
页码:51 / 56
页数:6
相关论文
共 50 条