Tuning and sensitivity enhancement of surface plasmon resonance sensor

被引:100
|
作者
Gupta, Gaurav
Kondoh, Jun
机构
[1] Shizuoka Univ, Grad Sch Elect Sci & Technol, Hamamatsu, Shizuoka 4328561, Japan
[2] Shizuoka Univ, Fac Engn, Hamamatsu, Shizuoka 4328561, Japan
关键词
surface plasmon resonance; angular sensitivity; refractive index; glass prism;
D O I
10.1016/j.snb.2006.06.005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The performance of a surface plasmon resonance (SPR) sensor depends on its design properties. In this paper, we described, both theoretically and experimentally, the role of the prism material in sensor design. The analyses were carried out by employing three prisms of different refractive indices and the reflection spectra were studied under the angular interrogation mode. The results proved that the choice of prism material can tailor the resonance condition and thus can effectively tune the working region of the sensor. Also, the experimental value of angular sensitivity increased from 94.46 degrees/RIU to 204.41 degrees/RIU on changing the refractive index of the prism from 1.597 to 1.456, without changing the other parameters. The variation of the angular sensitivity was in accordance with the analytical and numerical results. The dynamic range decreased and the full width at half maximum (FWHM) of the reflection spectra increased as the refractive index of the prism was lowered, thereby affecting the sensor's performance. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:381 / 388
页数:8
相关论文
共 50 条
  • [21] Surface Plasmon Resonance Sensors: Methods of Surface Functionalization and Sensitivity Enhancement
    O. V. Shynkarenko
    S. A. Kravchenko
    Theoretical and Experimental Chemistry, 2015, 51 : 273 - 292
  • [22] Enhancement of the Sensitivity of Surface Plasmon Resonance Biosensor by Modifying the Metal Surface
    Bae, Young Min
    Son, Seo Young
    Lee, Kyeong-Hee
    Kim, Kibok
    Seol, Seung Kwon
    Kim, Daeho
    JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2013, 9 (06) : 1060 - 1064
  • [23] Surface Plasmon Resonance Sensors: Methods of Surface Functionalization and Sensitivity Enhancement
    Shynkarenko, O. V.
    Kravchenko, S. A.
    THEORETICAL AND EXPERIMENTAL CHEMISTRY, 2015, 51 (05) : 273 - 292
  • [24] Sensitivity enhancement of graphene coated surface plasmon resonance biosensor
    Kamrun Nahar Shushama
    Md. Masud Rana
    Reefat Inum
    Md. Biplob Hossain
    Optical and Quantum Electronics, 2017, 49
  • [25] Sensitivity enhancement in surface plasmon resonance sensors - theoretical modeling
    Vlcek, J.
    Pistora, J.
    Lesnak, M.
    OPTICAL SENSORS 2009, 2009, 7356
  • [26] SURFACE-PLASMON SENSOR FOR ABSORPTION-SENSITIVITY ENHANCEMENT
    KANO, H
    KAWATA, S
    APPLIED OPTICS, 1994, 33 (22): : 5166 - 5170
  • [27] Sensitivity enhancement of surface plasmon resonance biosensing of small molecules
    Mitchell, JS
    Wu, YQ
    Cook, CJ
    Main, L
    ANALYTICAL BIOCHEMISTRY, 2005, 343 (01) : 125 - 135
  • [28] Sensitivity enhancement of surface plasmon resonance biosensor with colloidal gold
    Choi K.
    Youn H.
    Kim K.
    Choi J.
    Biotechnology and Bioprocess Engineering, 1998, 3 (1) : 19 - 23
  • [29] Sensitivity enhancement of graphene coated surface plasmon resonance biosensor
    Shushama, Kamrun Nahar
    Rana, Md Masud
    Inum, Reefat
    Hossain, Md Biplob
    OPTICAL AND QUANTUM ELECTRONICS, 2017, 49 (11)
  • [30] Tuning of spectral operation range of a waveguide surface plasmon resonance sensor
    Ctyroky, J
    Homola, J
    Skalsky, M
    ELECTRONICS LETTERS, 1997, 33 (14) : 1246 - 1248