A comparison of commercially-available automated and manual extraction kits for the isolation of total RNA from small tissue samples

被引:49
|
作者
Jeffries, Marlo K. Sellin [1 ,2 ]
Kiss, Andor J. [2 ,3 ]
Smith, Austin W. [2 ]
Oris, James T. [2 ]
机构
[1] Texas Christian Univ, Dept Biol, Ft Worth, TX 76129 USA
[2] Miami Univ, Dept Biol, Oxford, OH 45056 USA
[3] Miami Univ, Ctr Bioinformat & Funct Genom, Oxford, OH 45056 USA
来源
BMC BIOTECHNOLOGY | 2014年 / 14卷
关键词
RNA extraction; Gene expression; qPCR; RNA-Seq; Next generation sequencing; Microarray; Small tissues; Fathead minnow; MESSENGER-RNA; BLOOD RNA; QUALITY; DNA; INTEGRITY; IMPACT; PCR;
D O I
10.1186/s12896-014-0094-8
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Background: This study compared the performance of five commercially available kits in extracting total RNA from small eukaryotic tissue samples (<15 mg). Total RNA was isolated from fathead minnow (Pimephales promelas) tissues (spleen, blood, kidney, embryo, and larvae) using the Qiagen RNeasy (R) Plus Mini, Qiagen RNeasy (R) Plus Universal, Promega Maxwell (R) 16 LEV simplyRNA, Ambion MagMAX (TM)-96 and Promega SimplyRNA HT kits. Kit performance was evaluated via measures of RNA quantity (e.g., total RNA amount) and quality (e.g., ratio of absorbance at 260 and 280 nm, RNA integrity number (RIN), presence of gDNA). Results: With the exception of embryos, each kit generally extracted >= 5 mu g of total RNA from each sample. With regard to RNA quality, the RINs of RNA samples isolated via the Plus Mini and Maxwell (R) 16 kits were consistently higher than those of samples extracted via the remaining three kits and for all tissues, these kits produced intact RNA with average RIN values >= 7. The Plus Universal and SimplyRNA HT kits produced moderately degraded (RIN values <7, but >= 5), while the RNA recovered via the MagMAX (TM) kit tended to exhibit a high degree of degradation (RIN values <5). Conclusions: Each kit was generally capable of extracting the amount of RNA required for most downstream gene expression applications suggesting that RNA yield is unlikely to be a limiting factor for any of the kits evaluated. However, differences in the quality of RNA extracted via each of the kits indicate that these kits may differ in their ability to yield RNA acceptable for some applications. Overall, the findings of this study demonstrate that there are practical differences between commercially available RNA extraction kits that should be taken into account when selecting extraction methods to be used for isolating RNA designated for gene expression analysis.
引用
收藏
页数:13
相关论文
共 45 条
  • [21] COMPARATIVE ANALYSIS OF TOTAL RNA ISOLATION PROCEDURES FROM SMALL ADIPOSE TISSUE SAMPLES IN SHEEP
    Socol, Claudia-Terezia
    Sonea, C. G.
    Maerescu, Cristina
    Criste, F. L.
    REVISTA ROMANA DE MEDICINA VETERINARA, 2021, 31 (03): : 62 - 66
  • [22] Commercially available kits for manual and automatic extraction of nucleic acids from formalin-fixed, paraffin-embedded (FFPE) tissues
    Kocjan, Bostjan J.
    Hosnjak, Lea
    Poljak, Mario
    ACTA DERMATOVENEROLOGICA ALPINA PANNONICA ET ADRIATICA, 2015, 24 (03): : 47 - 53
  • [23] Comparative evaluation of four large-volume RNA extraction kits in the isolation of viral RNA from water samples
    Burgener, M
    Candrian, U
    Gilgen, M
    JOURNAL OF VIROLOGICAL METHODS, 2003, 108 (02) : 165 - 170
  • [24] Comparison of eight commercially available kits for DNA extraction from formalin-fixed paraffin-embedded tissues
    Janecka, Anna
    Adamczyk, Agnieszka
    Gasinska, Anna
    ANALYTICAL BIOCHEMISTRY, 2015, 476 : 8 - 10
  • [25] MicroRNA preparations from individual monogenean Gyrodactylus salaris-a comparison of six commercially available totalRNA extraction kits
    Fromm B.
    Harris P.D.
    Bachmann L.
    BMC Research Notes, 4 (1)
  • [26] Comparison of manual and automated nucleic acid extraction from whole-blood samples
    Riemann, Kathrin
    Adamzik, Michael
    Frauenrath, Stefan
    Egensperger, Rupert
    Schmid, Kurt W.
    Brockmeyer, Norbert H.
    Siffert, Winfried
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2007, 21 (04) : 244 - 248
  • [27] Comparison of automated and manual RNA isolation from stabilized peripheral blood samples (PBL) for expression analysis of colorectal cancer patients
    Molnar, Bela
    Szasz, Attila M.
    Galamb, Orsolya
    Kalmar, Alexandra
    Wichmann, Barnabas
    Spisak, Sandor
    Leiszter, Katalin
    Toth, Kinga
    Sipos, Ferenc
    Tulassay, Zsolt
    CANCER RESEARCH, 2012, 72
  • [28] A simple method of DNA extraction and STR typing from urine samples using a commercially available DNA/RNA extraction kit
    Yasuda, T
    Iida, R
    Takeshita, H
    Ueki, M
    Nakajima, T
    Kaneko, Y
    Mogi, K
    Tsukahara, T
    Kishi, K
    JOURNAL OF FORENSIC SCIENCES, 2003, 48 (01) : 108 - 110
  • [29] Comparison of commercial RNA extraction kits for preparation of DNA-free total RNA from Salmonella cells
    Rump L.V.
    Asamoah B.
    Gonzalez-Escalona N.
    BMC Research Notes, 3 (1)
  • [30] Simultaneous Isolation of Both Rna and DNA from Many Small Tissue Samples
    Katalin Lumniczky
    G. Sáfrány
    Acta Biologica Hungarica, 1997, 48 (2): : 253 - 257