Experimental verification for load rating of steel truss bridge using an improved Hamiltonian Monte Carlo-based Bayesian model updating

被引:13
|
作者
Baisthakur, Shubham [1 ]
Chakraborty, Arunasis [2 ]
机构
[1] Larson & Toubro ECC, Chennai 600089, Tamil Nadu, India
[2] Indian Inst Technol Guwahati, Civil Engn Dept, Gauhati, Assam, India
关键词
Bayesian Inference; Markov Chain Monte Carlo Simulation; Hamiltonian Monte Carlo Simulation; Finite element model updating; Bridge rating; RELIABILITY; SYSTEM; SIMULATION;
D O I
10.1007/s13349-021-00495-8
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The load rating of a steel truss bridge is experimentally identified in this study using an improved Bayesian model updating algorithm. The initial element model is sequentially updated to match the static and dynamic characteristics of the bridge. For this purpose, a modified version of the Hamiltonian Monte Carlo (HMC) simulation is adopted for closed-form candidate generation that helps in faster convergence compared to the Markov Chain Monte Carlo simulation. The updated model works as a digital twin of the original structure to predict its load-carrying capacity and performance under proof or design load. The proposed approach incorporates in-situ conditions in its formulation and helps to reduce the risk involved in bridge load testing at its full capacity. The rating factor for each member is estimated from the updated model, which also indicates the weak links and possible failure mechanism. The efficiency of the improved HMC-based algorithm is demonstrated using limited sensor data, which can be easily adopted for other existing bridges.
引用
收藏
页码:1093 / 1112
页数:20
相关论文
共 50 条
  • [21] Indirect Force Measurement via Hamiltonian Monte Carlo-Based Probabilistic Model of FSR Sensor
    Singh, Bharat
    Kumar, Rajesh
    Jakhar, Varsha
    IEEE SENSORS JOURNAL, 2023, 23 (24) : 30546 - 30554
  • [22] Improved Estimation and Uncertainty Quantification Using Monte Carlo-Based Optimization Algorithms
    Xu, Cong
    Baines, Paul
    Wang, Jane-Ling
    JOURNAL OF COMPUTATIONAL AND GRAPHICAL STATISTICS, 2015, 24 (03) : 771 - 791
  • [23] A Bayesian cure rate regression model using Hamiltonian Monte Carlo methods
    Cancho, Vicente G.
    Sacramento, Michele M.
    Ortega, Edwin M. M.
    de Moraes, Talita E. N. T.
    Cordeiro, Gauss M.
    COMMUNICATIONS IN STATISTICS-SIMULATION AND COMPUTATION, 2024,
  • [24] Model Order Identification for Cable Force Estimation Using a Markov Chain Monte Carlo-Based Bayesian Approach
    Zhan, Shaodong
    Li, Zhi
    Hu, Jianmin
    Liang, Yiping
    Zhang, Guanglie
    SENSORS, 2018, 18 (12)
  • [25] Neural network based numerical model updating and verification for a short span concrete culvert bridge by incorporating Monte Carlo simulations
    Lin, S. T. K.
    Lu, Y.
    Alamdari, M. M.
    Khoa, N. L. D.
    STRUCTURAL ENGINEERING AND MECHANICS, 2022, 81 (03) : 293 - 303
  • [26] An improved lung model, incorporating realistic random anatomical features, for Monte Carlo-based dosimetry
    Liang, L.
    Larsen, E.
    Chetty, I. J.
    MEDICAL PHYSICS, 2006, 33 (06) : 2285 - 2285
  • [27] Experimental verification of a commercial Monte Carlo-based dose calculation module for high-energy photon beams
    Kuenzler, Thomas
    Fotina, Irina
    Stock, Markus
    Georg, Dietmar
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (24): : 7363 - 7377
  • [28] Experimental Load Rating of a Steel Girder Bridge Using Structural Health Monitoring and Modeling
    Bell, E. S.
    Lefebvre, P. J.
    Sanayei, M.
    Sipple, J. D.
    Iplikcioglu, M.
    Brenner, B. R.
    BRIDGE MAINTENANCE, SAFETY, MANAGEMENT, RESILIENCE AND SUSTAINABILITY, 2012, : 322 - 329
  • [29] Bayesian inference for a single factor copula stochastic volatility model using Hamiltonian Monte Carlo
    Kreuzer, Alexander
    Czado, Claudia
    ECONOMETRICS AND STATISTICS, 2021, 19 : 130 - 150
  • [30] Dosimetric evaluation in Helical TomoTherapy for lung SBRT using Monte Carlo-based independent dose verification software
    Kosaka, Takahiro
    Takatsu, Jun
    Inoue, Tatsuya
    Iijima, Kotaro
    Suzuki, Michimasa
    Murakami, Naoya
    Shikama, Naoto
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (05):