Augmented Reality-Assisted Percutaneous Pedicle Screw Instrumentation: A Cadaveric Feasibility and Accuracy Study

被引:7
|
作者
Chang, Chih-Chang [1 ,2 ,3 ]
Kuo, Chao-Hung [1 ,2 ,3 ]
Chang, Hsuan-Kan [1 ,2 ]
Tu, Tsung-Hsi [1 ,2 ]
Fay, Li-Yu [1 ,2 ]
Wu, Jau-Ching [1 ,2 ]
Cheng, Henrich [1 ,2 ]
Huang, Wen-Cheng [1 ,2 ]
机构
[1] Taipei Vet Gen Hosp, Neurol Inst, Dept Neurosurg, Taipei 112201, Taiwan
[2] Natl Yang Ming Chiao Tung Univ, Sch Med, Taipei 112304, Taiwan
[3] Natl Yang Ming Chiao Tung Univ, Dept Biomed Engn, Taipei 112304, Taiwan
来源
APPLIED SCIENCES-BASEL | 2022年 / 12卷 / 10期
关键词
augmented reality (AR); minimally invasive spine surgery (MISS); 3D hologram; PLACEMENT;
D O I
10.3390/app12105261
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Percutaneous pedicle screw instrumentation is the keystone of minimally invasive spine surgery. Percutaneous screw placement demands experience and relies greatly on intra-operative image guidance. This study aims to validate the feasibility and accuracy of augmented-reality (AR)-assisted percutaneous pedicle screw instrumentation. One cadaveric torso was prepared for this study. After a pre-operative computed tomography (CT) scan, the images were transferred to an AR station to generate a 3D hologram. The 3D hologram and navigation images were projected to a pair of goggles with a display screen. With registration, the 3D spine hologram was overlayed onto the cadaver. Bilateral instrumentation from T6 to L5 was performed by two surgeons using AR assistance. A post-operative CT scan was obtained. The Gertzbein-Robbins scale (grade 0-3) was used for accuracy assessment. A total of 24 screws were placed. The overall screw accuracy was 87.5%. There were three major medial breaches that occurred on Rt T6/7/8, which were the most distant screws from the iliac reference. The cause of the three major medial breaches appeared to be related to their distance from the iliac reference. AR-assisted percutaneous pedicle screw instrumentation could improve anatomical visualization, facilitate surgical workflow, and provide an intuitive way of performing surgery.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Feasibility and safety of augmented reality-assisted urological surgery using smartglass
    H. Borgmann
    M. Rodríguez Socarrás
    J. Salem
    I. Tsaur
    J. Gomez Rivas
    E. Barret
    L. Tortolero
    World Journal of Urology, 2017, 35 : 967 - 972
  • [22] Augmenting Reality in Spinal Surgery: A Narrative Review of Augmented Reality Applications in Pedicle Screw Instrumentation
    Xiao, Sheng-Xian
    Wu, Wen-Tien
    Yu, Tzai-Chiu
    Chen, Ing-Ho
    Yeh, Kuang-Ting
    MEDICINA-LITHUANIA, 2024, 60 (09):
  • [23] Pedicle screw piercer with warning device - A technique to increase accuracy of pedicle screw placement A cadaveric study
    Lin Bin
    He Yong
    Xu Yang
    Zhang Bi
    Sha Mo
    Guo Zhi-Min
    INDIAN JOURNAL OF ORTHOPAEDICS, 2014, 48 (06) : 545 - 549
  • [24] Percutaneous, PMMA-augmented, pedicle screw instrumentation of thoracolumbar ankylotic spine fractures
    Buxbaum, Rina E.
    Shani, Adi
    Mulla, Hani
    Rod, Alon
    Rahamimov, Nimrod
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [25] Pedicle screw piercer with warning device - A technique to increase accuracy of pedicle screw placementA cadaveric study
    Lin Bin
    He Yong
    Xu Yang
    Zhang Bi
    Sha Mo
    Guo Zhi-Min
    Indian Journal of Orthopaedics, 2014, 48 : 545 - 549
  • [26] Percutaneous, PMMA-augmented, pedicle screw instrumentation of thoracolumbar ankylotic spine fractures
    Rina E. Buxbaum
    Adi Shani
    Hani Mulla
    Alon Rod
    Nimrod Rahamimov
    Journal of Orthopaedic Surgery and Research, 16
  • [27] Augmented reality-assisted skull base surgery
    Cabrilo, I.
    Sarrafzadeh, A.
    Bijlenga, P.
    Landis, B. N.
    Schaller, K.
    NEUROCHIRURGIE, 2014, 60 (06) : 304 - 306
  • [28] Augmented Reality-Assisted Ultrasound Breast Biopsy
    Costa, Nuno
    Ferreira, Luis
    de Araujo, Augusto R. V. F.
    Oliveira, Bruno
    Torres, Helena R. R.
    Morais, Pedro
    Alves, Victor
    Vilaca, Joao L.
    SENSORS, 2023, 23 (04)
  • [29] First in-human report of the clinical accuracy of thoracolumbar percutaneous pedicle screw placement using augmented reality guidance
    Yahanda, Alexander T.
    Moore, Emelia
    Ray, Wilson Z.
    Pennicooke, Brenton
    Jennings, Jack W.
    Molina, Camilo A.
    NEUROSURGICAL FOCUS, 2021, 51 (02) : 1 - 8
  • [30] Accuracy of Pedicle Screw Placement With Robotic Guidance System A Cadaveric Study
    Fujishiro, Takashi
    Nakaya, Yoshiharu
    Fukumoto, Shingo
    Adachi, Shu
    Nakano, Atsushi
    Fujiwara, Kenta
    Baba, Ichiro
    Neo, Masashi
    SPINE, 2015, 40 (24) : 1882 - 1889