Lossy transmission line simulation based on closed-form triangle impulse responses

被引:7
|
作者
Zhou, TD [1 ]
Dvorak, SL
Prince, JL
机构
[1] IBM Corp, Server Grp, Poughkeepsie, NY 12601 USA
[2] Univ Arizona, Ctr Elect Packaging Res, Dept Elect & Comp Engn, Tucson, AZ 85721 USA
关键词
closed-form triangle impulse response; frequency domain modal analysis; inverse Fourier transformation; lossy transmission lines; time-domain convolution; transfer functions; transmission line modeling;
D O I
10.1109/TCAD.2003.811445
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Analytical frequency-domain expressions for single and coupled transmission lines with triangular input waveforms are first developed. The inverse Fourier transform is then used to obtain an expression for the time-domain triangle impulse responses for frequency-independent transmission line parameters. The integral associated with the inverse Fourier transform is solved analytically using a differential-equation-based technique. Closed-form expressions for the triangle impulse responses are given in the form of incomplete Lipschitz-Hankel integrals (ILHI) of the first kind. The ILHI can be efficiently calculated using existing algorithms. Combining these closed-form expressions for the triangle impulse responses with a time-domain convolution method using a triangle impulse as a basis function, provides an accurate and efficient simulation method for very lossy transmission lines embedded within linear and nonlinear circuits.
引用
收藏
页码:748 / 755
页数:8
相关论文
共 50 条
  • [21] A Closed-Form Formula of Radiation and Total Efficiency for Lossy Multiport Antennas
    Wang, Min
    Loh, Tian-Hong
    Zhao, Yongjiu
    Xu, Qian
    IEEE ANTENNAS AND WIRELESS PROPAGATION LETTERS, 2019, 18 (12): : 2468 - 2472
  • [22] Passive closed-form transmission-line model for general purpose circuit simulators
    Dounavis, A
    Li, X
    Nakhla, M
    Achar, R
    1999 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST, VOLS 1-4, 1999, : 377 - 380
  • [23] Closed-Form Formulas for the Stochastic Electromagnetic Field Coupling to a Transmission Line With Arbitrary Loads
    Magdowski, Mathias
    Vick, Ralf
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2012, 54 (05) : 1147 - 1152
  • [24] CLOSED-FORM EXPRESSION FOR ENERGY DISSIPATION IN A LOW-LOSS TRANSMISSION-LINE
    YEE, KS
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1974, NS21 (01) : 1006 - 1008
  • [25] Closed-form impulse response model of non-line-of-sight single-scatter propagation
    Sun, Yu
    Zhan, Yafeng
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2016, 33 (04) : 752 - 757
  • [26] Closed-form expressions for the line-coupling parameters of coupled on-chip interconnects on lossy silicon substrate
    Chiu, CN
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2004, 43 (06) : 495 - 498
  • [27] Closed-form expressions for the line parameters of co-planar on-chip interconnects on lossy silicon substrates
    Luoh, A
    Weisshaar, A
    ELECTRICAL PERFORMANCE OF ELECTRONIC PACKAGING, 2002, : 341 - 344
  • [28] Irregular terms in the impulse response of a multiconductor lossy transmission line
    Maffucci, A
    Miano, G
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-FUNDAMENTAL THEORY AND APPLICATIONS, 1999, 46 (07): : 788 - 805
  • [29] A Closed-Form Transient Response of Coupled Transmission Lines
    Zahedi, Fatemeh
    Mehrshahi, Esfandiar
    Jahanian, Ali
    IEEE SYSTEMS JOURNAL, 2022, 16 (01): : 801 - 809
  • [30] Passive closed-form expression of RLCG transmission lines
    Tanji, Y
    Ushida, A
    Nakhla, MS
    2002 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL III, PROCEEDINGS, 2002, : 795 - 798