Influence of the cladding diameter of optical fiber on the simultaneous measurement of the refractive index and temperature of liquids using tilted fiber Bragg grating

被引:2
|
作者
Kameyama, Akihiro [1 ]
Katto, Masahito [2 ]
Yokotani, Atsushi [1 ]
机构
[1] Miyazaki Univ, Fac Engn, Miyazaki 8892192, Japan
[2] Miyazaki Univ, Ctr Collaborat Res & Community Cooperat, Miyazaki 8892192, Japan
关键词
D O I
10.7567/JJAP.55.068003
中图分类号
O59 [应用物理学];
学科分类号
摘要
We considered the influence of the core and cladding diameters on the simultaneous measurement of the refractive index and temperature of liquids using a tilted fiber Bragg grating (TFBG). When the cladding diameter of a TFBG was only reduced from 125 to 123 mu m, the calculated refractive index differed by 0.0068 from the expected value. When the core diameter was reduced from 9.6 to 7.8 mu m, the change was less than 0.0005. We found that equalization of cladding diameter is required to improve the precision of the simultaneous measurement of the refractive index and temperature of liquids. (C) 2016 The Japan Society of Applied Physics
引用
收藏
页数:3
相关论文
共 50 条
  • [21] All-fiber temperature and refractive index sensor based on a cascaded tilted Bragg grating and a Bragg grating
    Fang, Yitao
    He, Wei
    Zhang, Wen
    Meng, Fanyong
    Zhu, Lianqing
    Zhang, Kun
    Zhao, Hong
    JOURNAL OF OPTICAL TECHNOLOGY, 2021, 88 (02) : 100 - 105
  • [22] Wide Range Refractive Index Measurement Using a Multi-Angle Tilted Fiber Bragg Grating
    Chen, Xiaoyong
    Xu, Jian
    Zhang, Xuejun
    Guo, Tuan
    Guan, Bai-Ou
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2017, 29 (09) : 719 - 722
  • [23] Simultaneous temperature and refractive index measurement of liquid using a local micro-structured fiber Bragg grating
    曹晔
    杨寅飞
    杨秀峰
    童峥嵘
    Chinese Optics Letters, 2012, 10 (03) : 19 - 22
  • [24] TEMPERATURE-INSENSITIVE REFRACTIVE INDEX SENSOR BASED ON TILTED FIBER BRAGG GRATING
    Miao, Yinping
    Liu, Bo
    Tian, Shuang
    Zhao, Qida
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2009, 51 (02) : 479 - 483
  • [25] Simultaneous temperature and refractive index measurement of liquid using a local micro-structured fiber Bragg grating
    Cao, Ye
    Yang, Yinfei
    Yang, Xiufeng
    Tong, Zhengrong
    CHINESE OPTICS LETTERS, 2012, 10 (03)
  • [26] Simultaneous Measurement of Refractive Index, Temperature, and Strain Using Etched-Core Fiber Bragg Grating Sensors
    Lee, Sang-Mae
    Saini, Simarjeet S.
    Jeong, Myung-Yung
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2010, 22 (19) : 1431 - 1433
  • [27] Fiber modal interferometer with embedded fiber Bragg grating for simultaneous measurements of refractive index and temperature
    Gao, Shecheng
    Zhang, Weigang
    Zhang, Hao
    Geng, Pengcheng
    Lin, Wei
    Liu, Bo
    Bai, Zhiyong
    Xue, Xiaolin
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 188 : 931 - 936
  • [28] Simultaneous measurement of temperature and strain using a single fiber bragg grating on a tilted cantilever beam
    Mohsen Mansoursamaei
    Abdollah Malakzadeh
    Optical Review, 2021, 28 : 289 - 294
  • [29] Simultaneous measurement of temperature and strain using a single fiber bragg grating on a tilted cantilever beam
    Mansoursamaei, Mohsen
    Malakzadeh, Abdollah
    OPTICAL REVIEW, 2021, 28 (03) : 289 - 294
  • [30] Simultaneous measurement of refractive index, strain, and temperature based on a four-core fiber combined with a fiber Bragg grating
    Li, Chao
    Ning, Tigang
    Li, Jing
    Pei, Li
    Zhang, Chan
    Zhang, Chuanbiao
    Lin, Heng
    Wen, Xiaodong
    OPTICS AND LASER TECHNOLOGY, 2017, 90 : 179 - 184