MRI of the Pelvis in Women: 3D Versus 2D T2-Weighted Technique

被引:49
|
作者
Proscia, Nicole [1 ]
Jaffe, Tracy A. [1 ]
Neville, Amy M. [1 ]
Wang, Carolyn L. [1 ]
Dale, Brian M. [2 ]
Merkle, Elmar M. [1 ]
机构
[1] Duke Univ, Dept Radiol, Med Ctr, Durham, NC 27710 USA
[2] Siemens Healthcare, Morrisville, NC USA
关键词
3D; MRI; pelvis; SPACE; women; TURBO-SPIN-ECHO; FEMALE PELVIS; SEQUENCES; ANOMALIES;
D O I
10.2214/AJR.09.3226
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to compare triplanar 2D T2-weighted turbo spin-echo MR images with reformatted images from a 3D T2-weighted turbo spin-echo sequence in analogous planes with respect to acquisition time, image quality, artifacts, and lesion detection. MATERIALS AND METHODS. Forty-four consecutively enrolled women referred for pelvic MRI participated in the study. The protocol included 2D T2-weighted turbo spin-echo sequences in the axial, coronal, and sagittal planes and a single sagittal 3D T2-weighted turbo spin-echo sequence. The acquisition times of the 2D and 3D sequences were calculated. The sagittal 3D data sets were reformatted at 2-mm slice thickness in each plane and compared with the 2D data sets with respect to image quality, artifacts, and lesion detection. RESULTS. The mean acquisition time for the 3D sequence (419 seconds) was significantly shorter than acquisition time for the 2D sequences in three planes (728 seconds) (p < 0.0001). The readers favored the 3D reformats for cervical contrast (p = 0.005); otherwise, there was no significant difference between the 3D reformats and 2D data sets with regard to image quality and lesion detection. The 3D reformats were preferred with respect to respiratory (p < 0.001) and bowel (p < 0.001) motion. CONCLUSION. The 3D approach with multiplanar reconstructions is a promising tool for imaging the female pelvis because of time savings without compromise of image quality, the diagnostic information obtained, and the versatility of reconstructing images in any orientation.
引用
收藏
页码:254 / 259
页数:6
相关论文
共 50 条
  • [1] Evaluation of 3D T2-weighted Breast MRI
    Moran, C. J.
    Hargreaves, B. A.
    Saranathan, M.
    Daniel, B. L.
    [J]. CANCER RESEARCH, 2012, 72
  • [2] Preliminary Clinical Experience at 3 T With a 3D T2-Weighted Sequence Compared With Multiplanar 2D for Evaluation of the Female Pelvis
    Hecht, Elizabeth M.
    Yitta, Silaja
    Lim, Ruth P.
    Fitzgerald, Erin F.
    Storey, Pippa
    Babb, James S.
    Bani-baker, Kamil O.
    Bennett, Genevieve L.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (02) : W346 - W352
  • [3] Prostate Cancer: Comparison of 3D T2-Weighted With Conventional 2D T2-Weighted Imaging for Image Quality and Tumor Detection
    Rosenkrantz, Andrew B.
    Neil, Jeffry
    Kong, Xiangtian
    Melamed, Jonathan
    Babb, James S.
    Taneja, Samir S.
    Taouli, Bachir
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (02) : 446 - 452
  • [4] Automatic zonal segmentation of the prostate from 2D and 3D T2-weighted MRI and evaluation for clinical use
    Hamzaoui, Dimitri
    Montagne, Sarah
    Renard-Penna, Raphaele
    Ayache, Nicholas
    Delingette, Herve
    [J]. JOURNAL OF MEDICAL IMAGING, 2022, 9 (02) : 24001
  • [5] Comparison of 3D and 2D FSE T2-weighted MRI in the diagnosis of deep pelvic endometriosis: Preliminary results
    Bazot, M.
    Stivalet, A.
    Darai, E.
    Coudray, C.
    Thomassin-Naggara, I.
    Poncelet, E.
    [J]. CLINICAL RADIOLOGY, 2013, 68 (01) : 47 - 54
  • [6] Clinical applications of 3D T2-weighted MRI in pelvic imaging
    Lim, Kelvin K.
    Noe, Geertje
    Hornsey, Emma
    Lim, Ruth P.
    [J]. ABDOMINAL IMAGING, 2014, 39 (05): : 1052 - 1062
  • [7] Automated 2D Segmentation of Prostate in T2-weighted MRI Scans
    Jucevicius, J.
    Treigys, P.
    Bernataviciene, J.
    Briediene, R.
    Naruseviciute, I.
    Dzemyda, G.
    Medvedev, V.
    [J]. INTERNATIONAL JOURNAL OF COMPUTERS COMMUNICATIONS & CONTROL, 2017, 12 (01) : 53 - 60
  • [8] Clinical applications of 3D T2-weighted MRI in pelvic imaging
    Kelvin K. Lim
    Geertje Noe
    Emma Hornsey
    Ruth P. Lim
    [J]. Abdominal Imaging, 2014, 39 : 1052 - 1062
  • [9] Comparison of 3D FLAIR, 2D FLAIR, and 2D T2-Weighted MR Imaging of Brain Stem Anatomy
    Kitajima, M.
    Hirai, T.
    Shigematsu, Y.
    Uetani, H.
    Iwashita, K.
    Morita, K.
    Komi, M.
    Yamashita, Y.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (05) : 922 - 927
  • [10] A comparison study between 3D T2-weighted SPACE and conventional 2D T2-weighted turbo spin echo in assessment of carotid plaque
    Lv, Peng
    Dai, Yuanyuan
    Lin, Jiang
    Zhang, Weisheng
    Liu, Hao
    Liu, Hui
    Tang, Xiao
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (03): : 395 - 400