Evaluation of FRP and hybrid FRP cables for super long-span cable-stayed bridges

被引:139
|
作者
Wang, Xin [2 ]
Wu, Zhishen [1 ,2 ]
机构
[1] Ibaraki Univ, Dept Urban & Civil Engn, Hitachi, Ibaraki 3168511, Japan
[2] Southeast Univ, Int Inst Urban Syst Engn, Nanjing 210096, Peoples R China
关键词
Hybrid composites; FRP cable; Modelling; Super long-span cable-stayed bridge;
D O I
10.1016/j.compstruct.2010.01.023
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
This paper evaluates the safety factors, the applicable lengths, and relative cost of FRP (fiber reinforced polymer) and hybrid FRP cables that are potentially suitable for cable-stayed bridges with a super long-span of between 1000 m and 10,000 m. Following previous studies on 1000-m scale cable-stayed bridges with FRP cables, two kinds of hybrid FRP cables - the previously discussed hybrid basalt and carbon FRP (B/CFRP) cable and the newly-developed basalt and steel-wire FRP (B/SFRP) cable - as well as conventional steel cable. CFRP cable, and BFRP cable are further investigated focusing on their promise in meeting potential requirements for super long-span bridges. Some major results are as follows: (1) a three-stage model for determining safety factors of cables with different kinds and lengths is proposed; (2) a threshold of lambda(2) is suggested to achieve both high material and stiffness utilization efficiency, based on which the applicable lengths for different kinds of cables were evaluated; and (3) hybrid B/SFRP cables and BFRP cables are comparable in cost to steel cables within a 3000 m span, while hybrid B/CFRP cables and CFRP cables demonstrate a superior performance/cost ratio over a longer span. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2582 / 2590
页数:9
相关论文
共 50 条
  • [21] Structural Performance of Super-Long-Span Cable-Stayed Bridges with Steel and CFRP Hybrid Cables
    Sun, Shengjiang
    Mei, Kuihua
    Sun, Yiming
    Li, Bo
    Huang, Huanzi
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2020, 45 (05) : 3569 - 3579
  • [22] Structural Performance of Super-Long-Span Cable-Stayed Bridges with Steel and CFRP Hybrid Cables
    Shengjiang Sun
    Kuihua Mei
    Yiming Sun
    Bo Li
    Huanzi Huang
    Arabian Journal for Science and Engineering, 2020, 45 : 3569 - 3579
  • [23] Study on the safety assessment method for stay cables of long-span cable-stayed bridges
    Tianjin University, Tianjin 300072, China
    不详
    Tumu Gongcheng Xuebao, 2006, 9 (74-79):
  • [24] Evaluation of the Static and Dynamic Behaviors of Long-Span Suspension Bridges with FRP Cables
    Yang, Yaqiang
    Wang, Xin
    Wu, Zhishen
    JOURNAL OF BRIDGE ENGINEERING, 2016, 21 (12)
  • [25] CORROSION EFFECT ON CABLE STATE OF LONG-SPAN CABLE-STAYED BRIDGES
    Huang, Juan
    Tang, Li-Qun
    4TH INTERNATIONAL SYMPOSIUM ON LIFETIME ENGINEERING OF CIVIL INFRASTRUCTURE, 2009, : 366 - 371
  • [26] Construction sequence analysis of long-span cable-stayed bridges
    Granata, Michele Fabio
    Longo, Giuseppe
    Recupero, Antonino
    Arici, Marcello
    ENGINEERING STRUCTURES, 2018, 174 : 267 - 281
  • [27] Cracking of Longitudinal Diaphragms in Long-Span Cable-Stayed Bridges
    Guo, Tong
    Liu, Zhongxiang
    Pan, Shenjun
    Pan, Zhihong
    JOURNAL OF BRIDGE ENGINEERING, 2015, 20 (11)
  • [28] ESTABLISHMENT OF BASELINE MODELS FOR LONG-SPAN CABLE-STAYED BRIDGES
    Zhang, Jing
    Au, Francis T. K.
    PROCEEDINGS OF THE SECOND INTERNATIONAL POSTGRADUATE CONFERENCE ON INFRASTRUCTURE AND ENVIRONMENT, VOL 2, 2010, : 263 - 270
  • [29] Seismic Vulnerability Assessment of Long-Span Cable-Stayed Bridges
    Li, Gangjin
    Zhang, Wenhua
    ADVANCES IN CIVIL ENGINEERING, PTS 1-6, 2011, 255-260 : 2612 - +
  • [30] Seismic reliability analysis of long-span cable-stayed bridges
    School of Highway, Chang’an University, Xi’an, Shaanxi, China
    Open Civ. Eng. J., 1 (592-597): : 592 - 597