Determination of cyclosporine in saliva using liquid chromatography-tandem mass spectrometry

被引:25
|
作者
Mendonza, A
Gohh, R
Akhlaghi, F
机构
[1] Univ Rhode Isl, Dept Appl Pharmaceut Sci, Coll Pharm, Kingston, RI 02881 USA
[2] Brown Univ, Rhode Isl Hosp, Div Organ Transplantat, Sch Med, Providence, RI 02903 USA
关键词
cyclosporine; saliva; concentration; liquid chromatography tandem mass spectrometry;
D O I
10.1097/00007691-200410000-00016
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Saliva may offer an alternative specimen for the therapeutic monitoring of cyclosporine (CsA) in children and patients with difficult venous access. For a highly protein-bound drug such as CsA, saliva may also provide a practical approach for measuring the unbound concentration. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is ideally suited for the measurement of drugs in saliva. A solid-phase extraction technique, analytic liquid chromatography over an Aqua Perfect C-18 column, maintained at 65degreesC, and electrospray tandem mass spectrometry were used to quantify CsA in saliva. The method used cyclosporine C (CsC) as the internal standard. Mobile phase comprised of a 97:3 vol/vol mixture of methanol and 30 mmol ammonium acetate at a flow rate of 0.5 mL/min. Chromatograms using mass transitions of m/z 1219.9 --> m/z 1202.9 for CsA and m/z 1235.9 --> m/z 1218.9 for CsC were obtained. The calibration curve was linear from 1 to 300 mug/L with correlation coefficient values ranging from 0.9732 to 0.9968). The lower limit of quantification was 1 mug/L, and limit of detection was 0.6 mug/L with an average extraction recovery of 84.7 +/- 2.6% for CsA and 93.7 +/- 4.4% for CsC from the saliva matrix. The accuracy of the method ranged from 92% to 104.7%, and the intra- and interrun coefficients of variation were 6.9-12.2% and 8.3-12.1%, respectively. The correlation coefficient value between the CsA concentration measurements in 15 paired blood-saliva samples from kidney transplant recipients was 0.695 (P = 0.006). The noninvasive and simple method of saliva collection coupled with the LC-MS/MS quantification technique for CsA analysis would generate novel data that could benefit patients undergoing CsA therapy.
引用
收藏
页码:569 / 575
页数:7
相关论文
共 50 条
  • [31] Liquid chromatography-tandem mass spectrometry method for determination cyclosporine A, tacrolimus, sirolimus, everolimus and MPA in blood
    Brozmanova, H.
    Urinovska, R.
    Perinova, I
    Budakova, L.
    Grundmann, M.
    THERAPEUTIC DRUG MONITORING, 2011, 33 (04) : 540 - 540
  • [32] Determination of pharmaceuticals in bivalves using QuEChERS extraction and liquid chromatography-tandem mass spectrometry
    Nunez, Mireia
    Borrull, Francesc
    Fontanals, Nuria
    Pocurull, Eva
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (13) : 3841 - 3849
  • [33] Enantioselective determination of azelnidipine in human plasma using liquid chromatography-tandem mass spectrometry
    Kawabata, Kiyoshi
    Samata, Naozumi
    Urasaki, Yoko
    Fukazawa, Ichiro
    Uchida, Naoki
    Uchida, Eiji
    Yasuhara, Hajime
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 389 - 397
  • [34] Quantitative determination of methylnaltrexone in human serum using liquid chromatography-tandem mass spectrometry
    Oswald, Stefan
    Schumacher, Gitta
    Siegmund, Werner
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 56 (05) : 1079 - 1084
  • [35] Quantitative Determination of Adrenaline and Noradrenaline in Urine Using Liquid Chromatography-Tandem Mass Spectrometry
    A. Thomas
    H. Geyer
    H. J. Mester
    W. Schänzer
    E. Zimmermann
    M. Thevis
    Chromatographia, 2006, 64 : 587 - 591
  • [36] Determination of Flubendiamide and Chlorantraniliprole Residues in Vegetables Using Liquid Chromatography-Tandem Mass Spectrometry
    Ming-Rong, Qian
    Hu, Zhang
    Liqin, Wu
    Fei, Liu
    Xiang-Yun, Wang
    Hong-Mei, He
    Zhi-Min, Chne
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (05) : 702 - 706
  • [37] Determination of cortisol in hair using liquid chromatography-tandem mass spectrometry: a short review
    Decker Soares, Daniella Rheingantz
    Antunes, Marina Venzon
    Linden, Rafael
    BIOANALYSIS, 2021, 13 (14) : 1145 - 1155
  • [38] Determination of Nequinate and Buquinolate in Livestock Products Using Liquid Chromatography-Tandem Mass Spectrometry
    Nakajima, Takayuki
    Hayashi, Hiroshi
    Sasamoto, Takeo
    Kanda, Maki
    Kusano, Tomoko
    Matsushima, Youko
    Kanai, Setsuko
    Takeba, Kazue
    Nagayama, Toshihiro
    FOOD HYGIENE AND SAFETY SCIENCE, 2011, 52 (03): : 178 - 182
  • [39] Determination of β-agonist residues in bovine urine using liquid chromatography-tandem mass spectrometry
    Dickson, LC
    MacNeil, JD
    Lee, S
    Fesser, ACE
    JOURNAL OF AOAC INTERNATIONAL, 2005, 88 (01) : 46 - 56
  • [40] Determination of homocysteine in dried blood spots using liquid chromatography-tandem mass spectrometry
    Han Jichun
    Li Guanglin
    Wang Xiaochen
    Luo Yiqi
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2016, 34 (06) : 567 - 571