Visual acuity repeatability in keratoconus: Impact on sample size

被引:32
|
作者
Gordon, MO [1 ]
Schechtman, KB [1 ]
Davis, LJ [1 ]
McMahon, TT [1 ]
Schornack, J [1 ]
Zadnik, K [1 ]
机构
[1] Washington Univ, Sch Med, Dept Ophthalmol & Visual Sci, St Louis, MO 63110 USA
关键词
visual acuity; keratoconus; repeatability; sample size; low contrast visual acuity;
D O I
10.1097/00006324-199804000-00021
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. The purpose of this paper is to determine the repeatability of visual acuity measurement in keratoconus and to describe the impact of measurement repeatability on sample size. Methods, Approximately 10% of a 1209 patient sample in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study were selected randomly for a Repeat CLEK Study Visit. Patients were tested at the 15 CLEK Participating Clinics. The test-retest sample consisted of 134 keratoconus patients who met the entry criteria of the CLEK Study. High and low contrast Bailey-Lovie visual acuity was measured with the patient's habitual visual correction (entrance visual acuity monocularly and binocularly), and with the best correction monocularly (either the patient's rigid contact lens and over-refraction, or with a CLEK Study trial lens and appropriate over-refraction) at two visits separated by a median of 90 days (range 22 to 268 days). Results, The mean absolute differences between the number of letters correct at the two visits ranged from a low of 3.24 +/- 3.1 for entrance high contrast binocular acuity to a high of 5.48 +/- 5.1 for best corrected low contrast monocular acuity, Intraclass correlation coefficients ranged from 0.757 to 0.853, The visual acuity score was somewhat higher at the Repeat Visit than at the Baseline Visit when the examiners were different between visits. Conclusions. Given the variable vision reported by keratoconus patients, visual acuity in this sample was very repeatable. Repeatability was slightly poorer when different examiners tested visual acuity at the Baseline and Repeat Visits.
引用
下载
收藏
页码:249 / 257
页数:9
相关论文
共 50 条
  • [21] Repeatability of near visual acuity measurement at high and low contrast
    Lam, Andrew K. C.
    Tong, Cecilia
    Tse, Jimmy
    Yu, Man
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2008, 91 (05) : 447 - 452
  • [22] Repeatability and Sensitivity Validation of an ipad based Visual Acuity Application
    Guillon, Michel
    Pepe, Pasquale
    Patel, Kishan
    Gupta, Ruchi
    Patel, Trisha
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [23] Repeatability of Visual Acuity with a Chart Having Lines of Equivalent Legibility
    Stark, Lawrence
    Class, Scot
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [24] Children's visual acuity tests: Repeatability and sensitivity to blur
    Siderov, J
    Fricke, T
    Tiu, A
    Pellizzer, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 4524 - 4524
  • [25] EFFECT OF SIZE OF PUPIL ON VISUAL ACUITY
    CAMPBELL, FW
    GREGORY, AH
    NATURE, 1960, 187 (4743) : 1121 - 1123
  • [26] Visual acuity depends on perceived size
    Shinoda, H
    Ikeda, M
    OPTICAL REVIEW, 1998, 5 (01) : 65 - 68
  • [27] Visual Acuity Depends on Perceived Size
    Hiroyuki Shinoda
    Mitsuo Ikeda
    Optical Review, 1998, 5 : 65 - 68
  • [28] EFFECTS OF INTENSE CONTINUOUS AND IMPACT NOISE ON PUPIL SIZE AND VISUAL-ACUITY
    JONES, PD
    LOEB, M
    BULLETIN OF THE PSYCHONOMIC SOCIETY, 1974, 4 (NA4) : 252 - 252
  • [29] Visual Acuity and Contrast Sensitivity Depending on Keratoconus Apex's Position
    Liduma, Sanita
    Krumina, Gunta
    PERCEPTION, 2019, 48 : 40 - 40
  • [30] Visual acuity in patients with keratoconus: a comparison with matched regular myopic astigmatism
    Michael Mimouni
    Riham Najjar
    Gilad Rabina
    Igor Vainer
    Igor Kaiserman
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2019, 257 : 313 - 319