Radiation safety aspects of the linac coherent light source project at SLAC+

被引:0
|
作者
Rokni, S. H. [1 ]
Fasso, A. [1 ]
Mao, S. [1 ]
Vincke, H. [1 ]
机构
[1] Stanford Linear Accelerator Ctr, Menlo Pk, CA 94025 USA
关键词
shielding; accelerator; design;
D O I
10.1016/j.radmeas.2007.01.032
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The linac coherent light source (LCLS) is a self-amplified spontaneous emission based free electron laser (FEL) that is being designed and built at the Stanford Linear Accelerator Center (SLAC) by a multi-laboratory collaboration. This facility will provide ultra-short pulses of coherent X-ray radiation with the fundamental harmonic energy tunable over the energy range of 0.82-8.2 keV. One-third of the existing SLAC linac will compress and accelerate the electron beam to energies ranging from 4.5 to 14.35 GeV. The beam will then be transported through a 130-m long undulator, emit FEL and spontaneous radiation. After passing through the undulator, the electron beam is bent to the main electron dump. The LCLS will have two experiment halls as well as X-ray optics and infrastructure necessary to make use of the FEL for research and development in a variety of scientific fields. The facility design will incorporate features that would make it possible to expand in future such that up to six independent undulators can be used. While some of the radiation protection issues for the LCLS are similar to those encountered at both high-energy electron linacs and synchrotron radiation facilities, LCLS poses new challenges as well. Some of these new issues include: the length of the facility and of the undulator, the experimental floor in line with the electron beam and the occupancy Dear 0 degrees, and the very high instantaneous intensity of the FEL. The shielding design criteria, methodology, and results from Monte Carlo and analytical calculations are presented. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:S247 / S251
页数:5
相关论文
共 50 条
  • [21] Pure brilliance: the Linac Coherent Light Source
    不详
    PHYSICS WORLD, 2009, 22 (03) : 12 - 12
  • [22] The DREAM Endstation at the Linac Coherent Light Source
    Walter, Peter
    Holmes, Micheal
    Obaid, Razib
    Amores, Lope
    Cheng, Xianchao
    Cryan, James P.
    Glownia, James M.
    Li, Xiang
    Lin, Ming-Fu
    Ng, May Ling
    Robinson, Joseph
    Shivaram, Niranjan
    Yin, Jing
    Fritz, David
    James, Justin
    Castagna, Jean-Charles
    Osipov, Timur
    APPLIED SCIENCES-BASEL, 2022, 12 (20):
  • [23] Data systems for the Linac Coherent Light Source
    Thayer, J.
    Damiani, D.
    Ford, C.
    Gaponenko, I.
    Kroeger, W.
    O'Grady, C.
    Pines, J.
    Tookey, T.
    Weaver, M.
    Perazzo, A.
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2016, 49 : 1363 - 1369
  • [24] X-ray optics design studies for the SLAC 1.5-15 Å Linac Coherent Light Source (LCLS)
    Tatchyn, R
    Arthur, J
    Boyce, R
    Fasso, A
    Montgomery, J
    Vylet, V
    Walz, D
    Yotam, R
    Freund, AK
    Howells, M
    FREE ELECTRON LASERS 1998, 1999, : 397 - 406
  • [25] Measurements and modeling of coherent synchrotron radiation and its impact on the Linac Coherent Light Source electron beam
    Bane, K. L. F.
    Decker, F. -J.
    Ding, Y.
    Dowell, D.
    Emma, P.
    Frisch, J.
    Huang, Z.
    Iverson, R.
    Limborg-Deprey, C.
    Loos, H.
    Nuhn, H. -D.
    Ratner, D.
    Stupakov, G.
    Turner, J.
    Welch, J.
    Wu, J.
    PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2009, 12 (03):
  • [26] Relative bunch length monitor for the linac coherent light source (LCLS) using coherent edge radiation
    Loos, H.
    Borden, T.
    Emma, P.
    Frisch, J.
    Wu, J.
    2007 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-11, 2007, : 508 - 510
  • [27] The linac coherent light source (LCLS): A fourth-generation light source using the SLAG linac
    Winick, H
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1995, 75 : 1 - 8
  • [28] Effects of linac wakefield on CSR microbunching in the Linac Coherent Light Source
    Huang, Z
    Borland, M
    Emma, P
    Kim, KJ
    PROCEEDINGS OF THE 2003 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 2003, : 3138 - 3140
  • [29] Radiation properties of the Linac Coherent Light Source: Challenges for x-ray optics
    Arthur, J
    Tatchyn, R
    X-RAY FEL OPTICS AND INSTRUMENTATION, 2001, 4143 : 1 - 8
  • [30] Single Shot Spatial and Temporal Coherence Properties of the SLAC Linac Coherent Light Source in the Hard X-Ray Regime
    Gutt, C.
    Wochner, P.
    Fischer, B.
    Conrad, H.
    Castro-Colin, M.
    Lee, S.
    Lehmkuehler, F.
    Steinke, I.
    Sprung, M.
    Roseker, W.
    Zhu, D.
    Lemke, H.
    Bogle, S.
    Fuoss, P. H.
    Stephenson, G. B.
    Cammarata, M.
    Fritz, D. M.
    Robert, A.
    Gruebel, G.
    PHYSICAL REVIEW LETTERS, 2012, 108 (02)