Surface modification of Co-Cr-Mo implant alloy by laser interference lithography

被引:34
|
作者
Wei, Xiaofeng [1 ]
Li, Wenjun [1 ,3 ]
Liang, Bojian [2 ]
Li, Binglin [1 ]
Zhang, Jinjin [1 ]
Zhang, Linshuai [1 ]
Wang, Zuobin [1 ,3 ]
机构
[1] Changchun Univ Sci & Technol, Int Res Ctr Nano Handling & Mfg China, Changchun 130022, Peoples R China
[2] Jilin Univ, China Japan Union Hosp, Changchun 130033, Peoples R China
[3] Univ Bedfordshire, Joint Res Ctr Comp Controlled Nanomfg, Luton LU1 3JU, Beds, England
关键词
Co-Cr-Mo implant alloy; Laser interference lithography; Friction; Hardness; HALL-PETCH RELATIONSHIP; WEAR; FRICTION; JOINTS;
D O I
10.1016/j.triboint.2016.01.039
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This article studies the feasibility of using laser interference lithography (LIL) for surface modification of Co-Cr-Mo implant alloy which has been universally applied to joint materials in total joint replacements. The tribological performances and surface topography of the samples were studied by RTEC micro-friction and wear tester and scanning electron microscope (SEM). Hardness testing of the modified sample surfaces was carried out using the micro-hardness tester (MH-60). Experimental results indicate that the sample surface modified with laser interference lithography presents better tribological performances and hardness properties than those untreated materials, including a 64% friction coefficient reduction and 40% hardness enhancement, which is very promising to significantly reduce the mean revision rate of post primary total hip replacements in the future. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:212 / 217
页数:6
相关论文
共 50 条
  • [41] Effect of Ultrasonic Shock Treatment on Fine Structure of Co-Cr-Mo Alloy Surface
    Petrov, Yu. M.
    Trofimova, L. M.
    Prokopenko, G. L.
    Vasiliev, M. O.
    Filatova, V. S.
    METALLOFIZIKA I NOVEISHIE TEKHNOLOGII, 2009, 31 (05): : 673 - 685
  • [42] The advanced characterization of a new alloy by Co-Cr-Mo system
    Minciuna, M. G.
    Vizureanu, P.
    Achitei, D. C.
    Sandu, A. V.
    JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS, 2016, 18 (7-8): : 717 - 722
  • [43] Effects of grain size on development of athermal and strain induced ε martensite in Co-Cr-Mo implant alloy
    Huang, P
    López, HF
    MATERIALS SCIENCE AND TECHNOLOGY, 1999, 15 (02) : 157 - 164
  • [44] A dispersion strengthened Co-Cr-Mo alloy for medical implants
    Wang, KK
    Berlin, RM
    Gustavson, LJ
    COBALT-BASE ALLOYS FOR BIOMEDICAL APPLICATIONS, 1999, 1365 : 89 - 97
  • [45] BIOACTIVE DOUBLE GLASS COATINGS FOR CO-CR-MO ALLOY
    ANDERSSON, OH
    KARLSSON, KH
    HERO, H
    VEDEL, E
    YLIURPO, A
    PAJAMAKI, KJJ
    LINDHOLM, TS
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1995, 6 (04) : 242 - 247
  • [46] Passivation and mechanical property improvement of Co-Cr-Mo alloy
    Guo, Feifei
    Dong, Guangneng
    Dong, Guangneng, 1600, Science Press (34): : 1197 - 1201
  • [47] CUTTING CHARACTERISTICS OF CO-CR-MO ALLOY BIOCOMPATIBLE MATERIALS
    Hagino, Masahiro
    Su, Xin
    Inoue, Takashi
    PROGRESS OF MACHINING TECHNOLOGY, 2012, : 19 - 22
  • [48] Effect of the Remelting on Transformations in Co-Cr-Mo Prosthetics Alloy
    Kacprzyk, B.
    Szymczak, T.
    Gumienny, G.
    Klimek, L.
    ARCHIVES OF FOUNDRY ENGINEERING, 2013, 13 (03) : 47 - 50
  • [49] Study of passivation of Co-Cr-Mo alloy in physiologic serum
    Ramires, I.
    Rocha, L.
    Codaro, E.N.
    Guastaldi, A.C.
    Informacion Tecnologica, 1999, 10 (05): : 61 - 65
  • [50] CORROSION RESISTANCE OF Co-Cr-Mo ALLOY USED IN DENTISTRY
    Lukaszczyk, A.
    Augustyn-Pieniazek, J.
    ARCHIVES OF METALLURGY AND MATERIALS, 2015, 60 (01) : 523 - 528