Structure or Exchange? On the Feasibility of Chemical Exchange Detection with Balanced Steady-State Free Precession in Tissue - An In Vitro Study

被引:7
|
作者
Heule, Rahel [1 ]
Deshmane, Anagha [1 ]
Zaiss, Moritz [1 ]
Herz, Kai [1 ]
Ehses, Philipp [2 ]
Scheffler, Klaus [1 ,3 ]
机构
[1] Max Planck Inst Biol Cybernet, High Field Magnet Resonance, Max Planck Ring 11, D-72076 Tubingen, Germany
[2] German Ctr Neurodegenerat Dis DZNE, Bonn, Germany
[3] Univ Tubingen, Dept Biomed Magnet Resonance, Tubingen, Germany
基金
欧盟地平线“2020”;
关键词
bSSFP; profile asymmetry; chemical exchange; glucose; white matter; pig brain; MAGNETIZATION-TRANSFER; QUANTITATIVE DESCRIPTION; CEST-MRI; RELAXATION; WATER; ASYMMETRIES; SPILLOVER; SIGNAL;
D O I
10.1002/nbm.4200
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Balanced steady-state free precession imaging has recently been suggested for chemical exchange detection (bSSFPX). The objective of this work is to investigate the contributions of microstructural, chemical shift and chemical exchange effects to the asymmetry of the bSSFP profile at field strengths of 3 T and 9.4 T. To this end, in vitro bSSFPX experiments are performed for a range of repetition times and flip angles in glucose water solutions with different MnCl2 concentrations and tissue homogenates obtained from the brainstem of pig brains. The experimental results are compared to multi-pool Bloch-McConnell simulations. Additionally, the influence of white matter tract geometry is analyzed ex vivo in pig brain hemispheres measured at two different angles with respect to B-0. The detectable bSSFP profile asymmetry in glucose solutions with tissue-like relaxation times and white matter homogenates was consistent with Bloch-McConnell simulations but relatively small. In intact white matter tracts, the asymmetry was dominated by structural effects with a strong dependency on tract orientation relative to B-0. In tracts perpendicular to B-0, the asymmetry was approximate to 3-4 times higher than in the homogenates, thus barely affected by chemical exchange effects. In conclusion, chemical exchange-related bSSFP profile asymmetries are detectable in tissue homogenates, however, the observed asymmetry level is generally low and prone to confounding structural effects rendering in vivo chemical exchange detection with bSSFP challenging in the brain.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Intrinsic fat suppression in TIDE balanced steady-state free precession imaging
    Paul, Dominik
    Hennig, Juergen
    Zaitsev, Maxim
    MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (06) : 1328 - 1335
  • [22] Chemical Shift Selective Fat Imaging Using Transition Into Driven Equilibrium Balanced Steady-State Free Precession for Quantification of Adipose Tissue
    Paul, Dominik
    Sommer, Gregor
    Leupold, Jochen
    Hentschel, Michael
    Baumann, Tobias
    Ludwig, Ute
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2009, 33 (03) : 475 - 480
  • [23] STEADY-STATE METHODS FOR STUDY OF PLACENTAL EXCHANGE
    FABER, JJ
    FEDERATION PROCEEDINGS, 1977, 36 (12) : 2640 - 2646
  • [24] Feasibility of MRI of the Fetal Heart with Balanced Steady-State Free Precession Sequence Along Fetal Body and Cardiac Planes
    Saleem, Sahar N.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (04) : 1208 - 1215
  • [25] Cardiac balanced steady-state free precession MRI at 0.35 T: a comparison study with 1.5 T
    Rashid, Shams
    Han, Fei
    Gao, Yu
    Sung, Kyunghyun
    Cao, Minsong
    Yang, Yingli
    Hu, Peng
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2018, 8 (07) : 627 - 636
  • [26] Balanced Steady-State Free Precession Techniques Improve Detection of Residual Germ Cell Tumor for Treatment Planning
    Mehan, W. A., Jr.
    Buch, K.
    Brasz, M. F.
    Simonis, F. F. J.
    MacDonald, S.
    Rincon, S.
    Kirsch, J. E.
    Caruso, P.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2020, 41 (05) : 898 - 903
  • [27] Analytical Characterization of RF Phase-Cycled Balanced Steady-State Free Precession
    Lauzon, M. Louis
    Frayne, Richard
    CONCEPTS IN MAGNETIC RESONANCE PART A, 2009, 34A (03) : 133 - 143
  • [28] Parameter Estimation Approach to Banding Artifact Reduction in Balanced Steady-State Free Precession
    Bjork, Marcus
    Ingle, R. Reeve
    Gudmundson, Erik
    Stoica, Petre
    Nishimura, Dwight G.
    Barral, Joelle K.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (03) : 880 - 892
  • [29] Use of Balanced Steady-State Free Precession Sequences in Evaluation of Drop Metastases Reply
    Buch, K.
    Rincon, S.
    Caruso, P.
    Kirsch, J. E.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (05) : E21 - E21
  • [30] Physiological and Functional Magnetic Resonance Imaging Using Balanced Steady-state Free Precession
    Park, Sung-Hong
    Han, Paul Kyu
    Choi, Seung Hong
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (03) : 550 - 559