摘要
Balanced steady-state free precession imaging has recently been suggested for chemical exchange detection (bSSFPX). The objective of this work is to investigate the contributions of microstructural, chemical shift and chemical exchange effects to the asymmetry of the bSSFP profile at field strengths of 3 T and 9.4 T. To this end, in vitro bSSFPX experiments are performed for a range of repetition times and flip angles in glucose water solutions with different MnCl2 concentrations and tissue homogenates obtained from the brainstem of pig brains. The experimental results are compared to multi-pool Bloch-McConnell simulations. Additionally, the influence of white matter tract geometry is analyzed ex vivo in pig brain hemispheres measured at two different angles with respect to B-0. The detectable bSSFP profile asymmetry in glucose solutions with tissue-like relaxation times and white matter homogenates was consistent with Bloch-McConnell simulations but relatively small. In intact white matter tracts, the asymmetry was dominated by structural effects with a strong dependency on tract orientation relative to B-0. In tracts perpendicular to B-0, the asymmetry was approximate to 3-4 times higher than in the homogenates, thus barely affected by chemical exchange effects. In conclusion, chemical exchange-related bSSFP profile asymmetries are detectable in tissue homogenates, however, the observed asymmetry level is generally low and prone to confounding structural effects rendering in vivo chemical exchange detection with bSSFP challenging in the brain.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Balanced Steady-State Free Precession (bSSFP) from an effective field perspective: Application to the detection of chemical exchange (bSSFPX)
    Zhang, Shu
    Liu, Zheng
    Grant, Aaron
    Keupp, Jochen
    Lenkinski, Robert E.
    Vinogradov, Elena
    JOURNAL OF MAGNETIC RESONANCE, 2017, 275 : 55 - 67
  • [2] Investigating exchange and multicomponent relaxation in fully-balanced steady-state free precession imagaing
    Deoni, Sean C. L.
    Rutt, Brian K.
    Jones, Derek K.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (06) : 1421 - 1429
  • [3] On the application of balanced steady-state free precession to MR microscopy
    Baer, Sebastien
    Oerther, Thomas
    Weigel, Matthias
    Mueller, Angelina
    Hucker, Patrick
    Korvink, Jan G.
    Ko, Cheng-Wen
    Wapler, Matthias C.
    Leupold, Jochen
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2019, 32 (04) : 437 - 447
  • [4] Spiral balanced steady-state free precession cardiac imaging
    Nayak, KS
    Hargreaves, BA
    Hu, BS
    Nishimura, DG
    Pauly, JM
    Meyer, CH
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (06) : 1468 - 1473
  • [5] FMRI using balanced steady-state free precession (SSFP)
    Miller, Karla L.
    NEUROIMAGE, 2012, 62 (02) : 713 - 719
  • [6] On the application of balanced steady-state free precession to MR microscopy
    Sébastien Bär
    Thomas Oerther
    Matthias Weigel
    Angelina Müller
    Patrick Hucker
    Jan G. Korvink
    Cheng-Wen Ko
    Matthias C. Wapler
    Jochen Leupold
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2019, 32 : 437 - 447
  • [7] Concomitant gradient field effects in balanced steady-state free precession
    Sica, Christopher T.
    Meyer, Craig H.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (04) : 721 - 730
  • [8] Pure balanced steady-state free precession imaging (pure bSSFP)
    Schaeper, Jessica
    Bauman, Grzegorz
    Ganter, Carl
    Bieri, Oliver
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (04) : 1886 - 1893
  • [9] Motion resilience of the balanced steady-state free precession geometric solution
    Hoff, Michael N.
    Xiang, Qing-San
    Cross, Nathan M.
    Hippe, Daniel
    Andre, Jalal B.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (01) : 192 - 204
  • [10] Optimized balanced steady-state free precession magnetization transfer Imaging
    Bieri, O.
    Scheffler, K.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (03) : 511 - 518