Comparison of TriPath thin-layer technology with conventional methods on nongynecologic specimens

被引:17
|
作者
Nicol, TL [1 ]
Kelly, D [1 ]
Reynolds, L [1 ]
Rosenthal, DL [1 ]
机构
[1] Johns Hopkins Med Inst, Dept Pathol, Div Cytopathol, Baltimore, MD 21287 USA
关键词
laboratory diagnosis; laboratory techniques and procedures; TriPath; AutoCyte; thin-layer preparations;
D O I
10.1159/000328531
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
OBJECTIVE: To evaluate the use of the TriPath PREP(TM) (previously called AutoCyte) (TriPath Inc., Burlington, North Carolina, U.S.A.) in nongynecologic cytologic material by performing side-by-side comparison of conventional preparations with TriPath-prepared slides. STUDY DESIGN: Ail initial study of 613 cases (set A) was conducted to compare the TriPath PREP system with conventional methods for the evaluation of nongynecologic specimens, including urine, body cavity effusions, ct cerebrospinal fluid, pulmonary and gastrointestinal specimens. Paired cases were evaluated for cellularity, staining qualify, preservation and representation of diagnostic material. Subsequent changes in the automated technique warranted reevaluation of the TriPath method. The follow-up study of 259 cases (set B) was conducted with the same design as set A. Results of evaluated parameters were analyzed using the chi(2) test. RESULTS: Results of the two sets were strikingly different. Prior to technical changes made by the laboratory, the TriPath method was significantly inferior. In the second set, the preferred material was most commonly the TriPath-prepared material. In particular, the majority of urine samples were prepared better by the automated, thin-layer system. CONCLUSION The TriPath PREP system offers a reliable preparation of urine and has potential for other nongynecologic specimens, provided that careful attention is paid to technical details and some adjustments are made to account for specimen variability.
引用
收藏
页码:567 / 575
页数:9
相关论文
共 50 条
  • [31] COMPARISON OF METHODS OF DETECTION FOR FREE ESTROGENS AND ESTROGEN ACETATES ON THIN-LAYER CHROMATOGRAMS
    VARON, HH
    DARNOLD, HA
    MURPHY, M
    FORSYTHE, J
    STEROIDS, 1967, 9 (05) : 507 - +
  • [32] Thin-layer cytology applied to percutentous breast tissue specimens
    Penault-Llorca, F
    Klijanienko, J
    De Latour, MP
    Jacquemier, J
    Padoy, E
    Fabre, M
    Vielh, P
    ANNALES DE PATHOLOGIE, 2002, 22 : S57 - S59
  • [33] PHOSPHATIDYLGLYCEROL IN CONTAMINATED SPECIMENS - IMMUNOAGGLUTINATION COMPARED WITH THIN-LAYER CHROMATOGRAPHY
    KANEGSBERG, B
    FLETCHER, J
    ITANO, M
    GARITE, TJ
    CLINICAL CHEMISTRY, 1984, 30 (06) : 994 - 994
  • [34] NEW METHODS IN THIN-LAYER CHROMATOGRAPHY AND ELECTROPHORESIS
    MUNIER, RL
    ZEITSCHRIFT FUR ANALYTISCHE CHEMIE FRESENIUS, 1968, 236 (APR): : 358 - &
  • [35] Evaluation of thin-layer methods in urine cytology
    Wright, RG
    Halford, JA
    CYTOPATHOLOGY, 2001, 12 (05) : 306 - 313
  • [36] Cervicovaginal flora - Comparison of conventional pap smears and a liquid-based thin-layer preparation
    Takei, H
    Ruiz, B
    Hicks, J
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2006, 125 (06) : 855 - 859
  • [37] COMPARISON OF REPRODUCIBILITY IN PAPER AND THIN-LAYER CHROMATOGRAPHY
    MACEK, K
    JOURNAL OF CHROMATOGRAPHY, 1968, 33 (02): : 257 - &
  • [38] Granular cell tumour on conventional cytology and thin-layer smears
    Rossi, ED
    Mule, A
    Miraglia, A
    Cianfrini, F
    Zannoni, GF
    Fadda, G
    CYTOPATHOLOGY, 2005, 16 (05) : 259 - 261
  • [39] MEASUREMENT OF LOW CORROSION RATES - COMPARISON OF AC IMPEDANCE AND THIN-LAYER ACTIVATION METHODS
    WILLIAMS, DE
    ASHER, J
    CORROSION SCIENCE, 1984, 24 (03) : 185 - 196
  • [40] Thin-layer chromatographic method optimization of a Piper guineense extract: comparison with published methods
    Mgbeahuruike, E. E.
    Vuorela, H.
    Yrjonen, T.
    PLANTA MEDICA, 2015, 81 (16) : 1557 - 1557