Grounding fault protection with sampling value difference in ineffectively earthed power systems

被引:0
|
作者
Wang Yuanyuan [1 ]
Zeng Xiangjun [1 ]
Ma Hongjiang [1 ]
Xia Yunfeng [1 ]
Xu Yao [1 ]
机构
[1] Changsha Univ Sci & Technol, Sch Elect & Informat Engn, Changsha 410076, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
ineffectively earthed power system; grounding fault protection; generator stator protection; different protection; sampling value;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Traditional protection schemes are difficult to detect and isolate grounding faults in ineffectively earthed power systems, especially to detect generator stator grounding faults with selectivity in Multi-Generator-System. In order to improve them, two novel protections with sampling value difference is proposed by comparing different phase's current variations before and after single-phase grounding fault occurring in the paper. One is feeder grounding fault protection for distribution networks, and the other is generators stator grounding fault protection for Multi-Generator-System. The two protections are verified with EMTP simulations. Results show that the proposed feeder protection can correctly detect all kinds of grounding faults with high reliability, and the proposed generator protection can detect the generator with stator grounding fault selectively. The feeder protection can be implemented easily in Field Terminal Unit (FTU) and satisfy the requirement of distribution automation.
引用
收藏
页码:2060 / +
页数:2
相关论文
共 50 条
  • [41] Fault Analysis and Protection Scheme for Converter AC Three-phase Grounding of Bipolar HVDC Systems
    Xue S.
    Fan B.
    Liu C.
    Lu J.
    Liu B.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (01): : 21 - 30
  • [42] Ground Fault Analysis and Grounding Method of Static Power Converters in Flexible AC Traction Power Supply Systems
    Li, Ziming
    Li, Xiaoqian
    Wei, Yingdong
    Lu, Chao
    Lin, Yunzhi
    Li, Zengqin
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (05) : 5535 - 5546
  • [43] Single-phase grounding fault detection method for a distribution network based on phase voltage difference polarity value
    Liu F.
    Zeng X.
    Xie L.
    Yu K.
    Tang X.
    Wang Y.
    Deng Q.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2023, 51 (15): : 155 - 165
  • [44] High resistance grounding and fault finding on three phase three wire (delta) power systems
    Lubich, DH
    1997 IEEE ANNUAL TEXTILE, FIBER AND FILM INDUSTRY TECHNICAL CONFERENCE, 1997, : K1 - K5
  • [45] Improved AC Immunity of Ground Fault Protection in Span Power Systems
    Babineau, John
    Moschopoulos, Gerry
    INTELEC 08 - 30TH INTERNATIONAL TELECOMMUNICATIONS ENERGY, VOLS 1 AND 2, 2008, : 525 - +
  • [46] Adaptability analysis of fault component protection of power systems with wind farms
    Wang, Chenqing, 1600, Chinese Society for Electrical Engineering (34):
  • [48] High Impedance Fault Detection Protection Scheme for Power Distribution Systems
    Moloi, Katleho
    Davidson, Innocent
    MATHEMATICS, 2022, 10 (22)
  • [49] The Z-Source Breaker for Fault Protection in Ship Power Systems
    Maqsood, Atif
    Corzine, Keith
    2014 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION (SPEEDAM), 2014, : 307 - 312