Grounding fault protection with sampling value difference in ineffectively earthed power systems

被引:0
|
作者
Wang Yuanyuan [1 ]
Zeng Xiangjun [1 ]
Ma Hongjiang [1 ]
Xia Yunfeng [1 ]
Xu Yao [1 ]
机构
[1] Changsha Univ Sci & Technol, Sch Elect & Informat Engn, Changsha 410076, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
ineffectively earthed power system; grounding fault protection; generator stator protection; different protection; sampling value;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Traditional protection schemes are difficult to detect and isolate grounding faults in ineffectively earthed power systems, especially to detect generator stator grounding faults with selectivity in Multi-Generator-System. In order to improve them, two novel protections with sampling value difference is proposed by comparing different phase's current variations before and after single-phase grounding fault occurring in the paper. One is feeder grounding fault protection for distribution networks, and the other is generators stator grounding fault protection for Multi-Generator-System. The two protections are verified with EMTP simulations. Results show that the proposed feeder protection can correctly detect all kinds of grounding faults with high reliability, and the proposed generator protection can detect the generator with stator grounding fault selectively. The feeder protection can be implemented easily in Field Terminal Unit (FTU) and satisfy the requirement of distribution automation.
引用
收藏
页码:2060 / +
页数:2
相关论文
共 50 条
  • [1] Grounding Fault Protection with Phase Current Difference for Ineffectively Earthed Power Systems
    Wang Yuanyuan
    Zeng Xiangjun
    Su Sheng
    CONFERENCE RECORD OF THE 2006 IEEE INDUSTRY APPLICATIONS CONFERENCE, FORTY-FIRST IAS ANNUAL MEETING, VOL 1-5, 2006, : 2645 - 2650
  • [2] Ground fault protection for ineffectively earthed power systems
    Zeng, XJ
    Guo, ZG
    Su, S
    2004 International Conference on Power System Technology - POWERCON, Vols 1 and 2, 2004, : 1650 - 1654
  • [3] Grounding fault protection based on fault resistance measurement for ineffectively earthed distribution systems
    School of Electrical and Information Engineering, Changsha University of Science and Technology, Changsha 410076, China
    不详
    Gaodianya Jishu, 2007, 1 (26-30): : 26 - 30
  • [4] A Novel Single Phase Grounding Fault Protection Scheme Without Threshold Setting for Neutral Ineffectively Earthed Power Systems
    Zeng, Xiangjun
    Yu, Kun
    Wang, Yuanyuan
    Xu, Yao
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2016, 2 (03): : 73 - 81
  • [5] Ground fault protection scheme using leakage current in ineffectively earthed power systems
    Yuanyuan, Wang
    Xiangjun, Zeng
    Choi, S. S.
    2007 CONFERENCE PROCEEDINGS IPEC, VOLS 1-3, 2007, : 488 - +
  • [6] Resonance measurement of capacitance current in ineffectively earthed power systems
    Yi, W. T.
    Zeng, X. J.
    Choi, S. S.
    Liu, Z. L.
    TENCON 2007 - 2007 IEEE REGION 10 CONFERENCE, VOLS 1-3, 2007, : 1182 - +
  • [7] Grounding Faulted Feeder Detection Methods Applied in Chinese Ineffectively Earthed Distribution Systems
    Zeng Xiangjun
    Xia Yunfeng
    Ma Hongjiang
    Wang Yuanyuan
    CONFERENCE RECORD OF THE 2007 IEEE INDUSTRY APPLICATIONS CONFERENCE FORTY-SECOND IAS ANNUAL MEETING, VOLS. 1-5, 2007, : 1348 - 1352
  • [8] A novel method of measuring capacitance current for ineffectively earthed power systems
    Xu, Y.
    Zeng, X. J.
    Choi, S. S.
    Liu, Z. L.
    TENCON 2007 - 2007 IEEE REGION 10 CONFERENCE, VOLS 1-3, 2007, : 1151 - +
  • [10] A novel technique for measuring grounding capacitance and grounding fault resistance in ineffectively grounded power system
    Zeng, XJ
    Yin, XG
    Zhang, Z
    Chen, DS
    Yu, YY
    INTERNATIONAL CONFERENCE ON SENSORS AND CONTROL TECHNIQUES (ICSC 2000), 2000, 4077 : 324 - 327