Flow-injection analysis with fluorescence detection for the determination of trace levels of ammonium in seawater

被引:67
|
作者
Watson, RJ
Butler, ECV
Clementson, LA
Berry, KM
机构
[1] CSIRO, Hobart, Tas 7001, Australia
[2] Univ Tasmania, Antarctic Climate & Ecosyst CRC, Hobart, Tas 7001, Australia
来源
JOURNAL OF ENVIRONMENTAL MONITORING | 2005年 / 7卷 / 01期
关键词
D O I
10.1039/b405924g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method using flow-injection, gas-diffusion, derivatisation and then fluorescent detection has been established for ammonium ion determination in seawater. The fluorescent derivative formed by reacting ortho-phthaldialdehyde (OPA) and sulfite with ammonia gives high sensitivity while removing potential interferences. This is required to measure the low concentrations of ammonium often seen in the open ocean. The experimental conditions (flow-rate, reagent concentrations, membrane configurations, etc.) were manipulated to improve performance. For a sample throughput of 30 samples h(-1), the limit of detection was 7 nM, the coefficient of variation was 5.7% at 800 nM, and the calibration curve was linear to at least 4 mumol L-1. Interferences were minimised by a gaseous diffusion step. Volatile small molecular-weight amines as interferents were discriminated against by this method. They neither passed through the membrane as efficiently as ammonia, nor reacted as readily with OPA when sulfite was the reductant. Contamination by ammonia from laboratory and shipboard sources complicates application of the method to natural waters, especially measurement of low concentrations (< 100 nM) in open-ocean waters. Steps to overcome contamination are described in detail. Some results are presented for ammonium determination in Southern Ocean and Huon Estuary (Tasmania) waters.
引用
收藏
页码:37 / 42
页数:6
相关论文
共 50 条
  • [41] Trace Levels Determination of Ammonium by Flow Injection Analysis Using Gas-Diffusion and Capacitively Coupled Contactless Conductivity Detection
    Braz, Henrique L.
    Ito, Debora T.
    Fracassi da Silva, Jose A.
    do Lago, Claudimir L.
    Pedrotti, Jairo J.
    ELECTROANALYSIS, 2011, 23 (11) : 2594 - 2600
  • [42] FLOW-INJECTION ANALYSIS FOR TRACE ALUMINUM WITH ONLINE PRECONCENTRATION AND SPECTROPHOTOMETRIC DETECTION
    KOBAYASHI, J
    BABA, M
    MIYAZAKI, M
    ANALYTICAL SCIENCES, 1994, 10 (02) : 287 - 291
  • [43] Determination of trace amounts of phosphate by flow-injection photometry
    Karthikeyan, S
    Hashigaya, S
    Kajiya, T
    Hirata, S
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (07) : 1842 - 1846
  • [44] A FLOW-INJECTION METHOD FOR THE DETERMINATION OF TRACE AMOUNTS OF CHLORIDE
    LACH, G
    BACHMANN, K
    ANALYTICA CHIMICA ACTA, 1987, 196 : 163 - 169
  • [45] Flow-injection chemiluminescent determination of trace nitrite in water
    Wang, XF
    Shi, X
    Pi, YQ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (06) : 865 - 868
  • [46] Determination of trace amounts of phosphate by flow-injection photometry
    Sathrugnan Karthikeyan
    Seigo Hashigaya
    Tasuku Kajiya
    Shizuko Hirata
    Analytical and Bioanalytical Chemistry, 2004, 378 : 1842 - 1846
  • [47] Determination of ozone in aqueous by flow-injection analysis with chemiluminescence detection
    Jin, BH
    He, Y
    Zhuang, ZX
    Wang, XR
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (04) : 580 - 583
  • [48] DETERMINATION OF THE PESTICIDE GUTHION BY FLOW-INJECTION ANALYSIS WITH AMPEROMETRIC DETECTION
    MENDEZ, JH
    MARTINEZ, RC
    GONZALO, ER
    TRANCON, JP
    ELECTROANALYSIS, 1990, 2 (06) : 487 - 491
  • [49] DETERMINATION OF HYDRAZINE DERIVATIVES BY FLOW-INJECTION ANALYSIS WITH SPECTROPHOTOMETRIC DETECTION
    EVGENYEV, MI
    GARMONOV, SY
    EVGENYEVA, II
    BUDNIKOV, HC
    TALANTA, 1995, 42 (10) : 1465 - 1469
  • [50] DETERMINATION OF MAGNESIUM BY FLAME AAS DETECTION WITH FLOW-INJECTION ANALYSIS
    KUBAN, V
    KOMAREK, J
    CAJKOVA, D
    ZDRAHAL, Z
    CHEMICAL PAPERS, 1990, 44 (03): : 339 - 346