Does C-reactive protein monitoring after colorectal resection with anastomosis give any practical benefit for patients with intra-abdominal septic complications?

被引:9
|
作者
Mik, M. [1 ]
Berut, M. [1 ]
Dziki, L. [1 ]
Dziki, A. [1 ]
机构
[1] Med Univ Lodz, Dept Gen & Colorectal Surg, Plac Hallera 1, PL-91647 Lodz, Poland
关键词
C-reactive protein; colorectal cancer; anastomotic leak; septic complications; POSTOPERATIVE INFECTIVE COMPLICATIONS; INFLAMMATORY COMPLICATIONS; SURGERY; LEAKAGE; METAANALYSIS; PREDICTOR; CANCER; PROCALCITONIN;
D O I
10.1111/codi.13386
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
AimThis study aimed to assess the influence of the C-reactive protein (CRP) level on the early outcome after elective colorectal resection. MethodPatients with colorectal cancer operated on between 2006 and 2013 were identified retrospectively. They were divided into a study group operated on between 2010 and 2013 when CRP was measured routinely on the fourth postoperative day and a control group operated on between 2006 and 2009 when the CRP level was not measured routinely. Mortality, intra-abdominal septic complications (IASC), abscesses and anastomotic leakage (AL), the need for reoperation, the interval from index surgery to relaparotomy, length of hospital stay and imaging studies were compared by multivariate analysis. ResultsA total of 1189 patients were assessed, including 598 (50.3%) in the study group (mean age 61.313years; 282 female) and 591 (49.7%) in the control group (mean age 61.8 +/- 11years; 267 female). There were seven (1.2%) postoperative deaths in the study group and nine (1.5%) in the control group (P=0.598). Abdominal ultrasound (US) was performed more often in the study group [97 (16.2%) vs 71 (12.0%); P=0.037]. In the study group the interval to diagnosis of IASC was shorter than in the control group (5.7 +/- 1.5days vs 7.3 +/- 1.3days; P=0.029). The decision to reoperate was also made earlier in the study group (6.2 +/- 1.7days vs 7.4 +/- 2.8days; P=0.043). ConclusionRoutine measurement of CRP can help to make an earlier diagnosis of IASC and earlier decision for relaparotomy, without any influence on mortality or length of hospital stay.
引用
收藏
页码:O252 / O259
页数:8
相关论文
共 50 条
  • [31] Early detection of infectious complications using C-reactive protein and the procalcitonin levels after laparoscopic colorectal resection: a prospective cohort study
    Tatsuoka, Teppei
    Okuyama, Takashi
    Takeshita, Emiko
    Oi, Haruka
    Noro, Takuji
    Mitsui, Takashi
    Yoshitomi, Hideyuki
    Oya, Masatoshi
    SURGERY TODAY, 2021, 51 (03) : 397 - 403
  • [32] Does investigating an elevated C-reactive protein detect infectious complications earlier after major colorectal surgery? A prospective clinical trial
    Singh, Primal
    Ganguly, Timothy
    Do, Jee Eun
    Murphy, Elizabeth
    ANZ JOURNAL OF SURGERY, 2024, 94 (09) : 1610 - 1616
  • [33] C-Reactive Protein Values After Surgery for Inflammatory Bowel Disease: Is It Still A Good Marker For Intra-Abdominal Complication? A Retrospective Cohort Study of, 347 procedures
    Gaspard, B.
    Alexandre, C.
    Thibault, V.
    Lauren, O.
    Clotilde, D.
    Najim, C.
    Yann, P.
    Lefevre, J.
    JOURNAL OF CROHNS & COLITIS, 2022, 16 : I393 - I393
  • [34] C-Reactive Protein Values After Surgery for Inflammatory Bowel Disease: Is It Still A Good Marker For Intra-Abdominal Complication? A Retrospective Cohort Study of, 347 procedures
    Gaspard, B.
    Alexandre, C.
    Thibault, V.
    Lauren, O.
    Clotilde, D.
    Najim, C.
    Yann, P.
    Lefevre, J.
    JOURNAL OF CROHNS & COLITIS, 2022, 16 : I393 - I393
  • [35] The study of relationships between intra-abdominal obesity and high sensitive C-reactive protein, tissue inhibitor of metalloproteinase-1 in patients with coronary heart disease
    Zhao, Xingshan
    Wang, Jihong
    Zhai, Jinjin
    Lan, Yonghao
    Zheng, Mei
    Cheng, Xiaoguang
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (16) : C142 - C143
  • [36] Diagnostic accuracy of C-reactive protein and white blood cell counts in the early detection of inflammatory complications after open resection of colorectal cancer: a retrospective study of 1187 patients
    Naef, F.
    Warschkow, R.
    Tarantino, I.
    Torzewski, M.
    Lange, J.
    Steffen, T.
    BRITISH JOURNAL OF SURGERY, 2011, 98 : 14 - 14
  • [37] C-Reactive Protein and Procalcitonin as Early Markers of Septic Complications after Laparoscopic Sleeve Gastrectomy in Morbidly Obese Patients Within an Enhanced Recovery After Surgery Program
    Luis Munoz, Jose
    Ruiz-Tovar, Jaime
    Miranda, Elena
    Lorena Berrio, Diana
    Moya, Pedro
    Gutierrez, Manuel
    Flores, Raquel
    Pico, Carlos
    Perez, Ana
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2016, 222 (05) : 831 - 837
  • [38] Timing of biologics discontinuation is not associated with postoperative complications (POCs), infective complications, bleeding, or intra-abdominal septic complications (IASCs) after primary ileocecal resection for Crohn's Disease: a retrospective analysis of 237 patients in a tertiary centre.
    Calini, G.
    Canavese, A.
    Dajti, G.
    Cardelli, S.
    Rizzello, F.
    Gionchetti, P.
    Gilberto, P.
    Rottoli, M.
    JOURNAL OF CROHNS & COLITIS, 2024, 18 : I846 - I848
  • [39] Monitoring of C-reactive protein after allogeneic bone marrow transplantation identifies patients at risk of severe transplant-related complications and mortality
    R Schots
    L Kaufman
    I Van Riet
    P Lacor
    F Trullemans
    M De Waele
    B Van Camp
    Bone Marrow Transplantation, 1998, 22 : 79 - 85
  • [40] Monitoring of C-reactive protein after allogeneic bone marrow transplantation identifies patients at risk of severe transplant-related complications and mortality
    Schots, R
    Kaufman, L
    Van Riet, I
    Lacor, P
    Trullemans, F
    De Waele, M
    Van Camp, B
    BONE MARROW TRANSPLANTATION, 1998, 22 (01) : 79 - 85