Accuracy of prostate volume measurements in vitro using three-dimensional ultrasound

被引:68
|
作者
Elliot, TL
Downey, DB
Tong, SD
McLean, CA
Fenster, A
机构
[1] UNIV HOSP, DEPT DIAGNOST RADIOL & NUCL MED, LONDON, ON N6A 5A5, CANADA
[2] JOHN P ROBARTS RES INST, LONDON, ON N6A 5K8, CANADA
[3] UNIV WESTERN ONTARIO, UNIV HOSP, DEPT PATHOL, LONDON, ON N6A 5A5, CANADA
基金
英国医学研究理事会;
关键词
prostate hypertrophy; neoplasms; three-dimensional ultrasound;
D O I
10.1016/S1076-6332(05)80673-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. We assessed the ability of a three-dimensional (3D) Methods. Multiple two-dimensional ultrasound images of cadaver prostates scanned in a water bath were reconstructed into three-dimensional (3D) images. The volumes of the prostates were calculated from these 3D images and compared with the actual volumes. Multiple 3D ultrasound volume readings were evaluated for precision. Results. The slope of the best-fit line correlating 3D ultrasound estimated volume and true volume was 1.006 +/- 0.007. The average error was 0.36 +/- 1.17 cm(3); the coefficient of determination (r(2)), which is the measure of the straight-line relationship, was .9997; and the standard error was 1.15 cm(3). Conclusion. Three-dimensional ultrasound images accurately reflect true prostate volumes measured in vitro.
引用
收藏
页码:401 / 406
页数:6
相关论文
共 50 条
  • [1] Three-dimensional ultrasound: Accuracy of distance and volume measurements
    Riccabona, M
    Nelson, TR
    Pretorius, DH
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1996, 7 (06) : 429 - 434
  • [2] Accuracy of prostate volume measurements using transrectal multiplanar three-dimensional sonography
    Giubilei, G
    Ponchietti, R
    Biscioni, S
    Fanfani, A
    Ciatto, S
    Di Loro, F
    Gavazzi, A
    Mondaini, N
    [J]. INTERNATIONAL JOURNAL OF UROLOGY, 2005, 12 (10) : 936 - 938
  • [3] Transvaginal three-dimensional ultrasound: Accuracy of follicular volume measurements
    KyeiMensah, A
    Zaidi, J
    Pittrof, R
    Shaker, A
    Campbell, S
    Tan, SL
    [J]. FERTILITY AND STERILITY, 1996, 65 (02) : 371 - 376
  • [4] Accuracy of in-vitro volume estimation of small structures using three-dimensional ultrasound
    Berg, S
    Torp, H
    Blaas, HG
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (03): : 425 - 432
  • [5] Accuracy of three-dimensional transvaginal ultrasound in uterus volume measurements;: Comparison with two-dimensional ultrasound
    Yaman, C
    Jesacher, K
    Pölz, W
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (12): : 1681 - 1684
  • [6] In vitro measurement accuracy of three-dimensional ultrasound
    Zotz, RJ
    Trabold, T
    Bock, A
    Kollmann, C
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2001, 18 (02): : 149 - 156
  • [7] Variability and accuracy of measurements of prostate brachytherapy seed position in vitro using three-dimensional ultrasound:: An intra- and inter-observer study
    Blake, CC
    Elliot, TL
    Slomka, PJ
    Downey, DB
    Fenster, A
    [J]. MEDICAL PHYSICS, 2000, 27 (12) : 2788 - 2795
  • [8] Accuracy and precision of in vitro volumetric measurements by three-dimensional sonography
    Wong, J
    Gerscovich, EO
    Cronan, MS
    Seibert, JA
    [J]. INVESTIGATIVE RADIOLOGY, 1996, 31 (01) : 26 - 29
  • [9] Intervendor Consistency and Accuracy of Left Ventricular Volume Measurements Using Three-Dimensional Echocardiography
    Muraru, Denisa
    Cecchetto, Antonella
    Cucchini, Umberto
    Zhou, Xiao
    Lang, Roberto M.
    Romeo, Gabriella
    Vannan, Mani
    Mihaila, Sorina
    Miglioranza, Marcelo Haertel
    Iliceto, Sabino
    Badano, Luigi P.
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2018, 31 (02) : 158 - +
  • [10] Intervendor consistency and accuracy of left ventricular volume measurements using three-dimensional echocardiography
    Cecchetto, A.
    Muraru, D.
    Marra, M. Perazzolo
    Cucchini, U.
    Romeo, G.
    Zhou, X.
    Mihaila, S.
    Iliceto, S.
    Lang, R. M.
    Badano, L. P.
    [J]. EUROPEAN HEART JOURNAL, 2014, 35 : 286 - 286