Variability and accuracy of measurements of prostate brachytherapy seed position in vitro using three-dimensional ultrasound:: An intra- and inter-observer study

被引:23
|
作者
Blake, CC
Elliot, TL
Slomka, PJ
Downey, DB
Fenster, A
机构
[1] John P Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] London Hlth Sci Ctr, Dept Radiol, London, ON N6A 5K8, Canada
[3] Univ Western Ontario, Dept Med Biophys, London, ON N6A 5K8, Canada
关键词
brachytherapy; 3D Ultrasound; seed localization; prostate brachytherapy;
D O I
10.1118/1.1326448
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This paper is a step in investigating whether three-dimensional (3D) ultrasound can be used intraoperatively to replace Computed Tomography (CT) for localization of brachytherapy seeds. In order to quantify the accuracy and variability of seed localization without introducing effects due to tissues, we first report our results with test phantoms. An inter- and intra-observer study was performed to assess the variability of 2 3D ultrasound scan acquisition methods: Tilt 3D scanning and pull-back 3D scanning. Seven observers measured the positions of gold seed markers in an agar phantom twice in each of the three orthogonal image planes. An analysis of variance (ANOVA) was performed to determine the intra- and inter-observer standard errors of measurement (SEM) and the minimum detectable changes in marker position (Deltap). Average intra- and inter-observer SEMs for the tilt scan 3D image were 0.36 and 0.40 mm, respectively. Measurements of the pull-back scan 3D image yielded average intra- and inter-observer SEM of 0.46 and 0.49 mm, respectively. A paired difference analysis showed that the lower SEM for the tilt 3D scan image were statistically significant at a significance level of alpha =0.05. The accuracy of the US measurements was tested by determining marker coordinates from CT images of the phantom in a stereotactic head frame. CT coordinates were matched to the ultrasound (US) coordinates by means of an affine transform. Average matching errors in x, y, and z were 0.02, 0.10, and -0.02 mm, respectively. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)01012-9].
引用
收藏
页码:2788 / 2795
页数:8
相关论文
共 50 条
  • [1] Intra- and inter-observer variability of uterine measurements with three-dimensional ultrasound and implications for clinical practice
    Saravelos, Sotirios H.
    Li, Tin-Chiu
    [J]. REPRODUCTIVE BIOMEDICINE ONLINE, 2015, 31 (04) : 557 - 564
  • [2] Intra- and inter-observer variability in antral follicle number with three-dimensional ultrasound.
    Session, DR
    Hemkumar, S
    Phy, JL
    Lesnick, TG
    Dumesic, DA
    [J]. JOURNAL OF THE SOCIETY FOR GYNECOLOGIC INVESTIGATION, 2004, 11 (02) : 136A - 137A
  • [3] Intra- and inter-observer variability and reliability of prostate volume measurement via two-dimensional and three-dimensional ultrasound imaging
    Tong, SD
    Cardinal, HN
    McLoughlin, RF
    Downey, DB
    Fenster, A
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (05): : 673 - 681
  • [4] Intra- and inter-observer variability and reliability of prostate volume measurement via two-dimensional and three-dimensional ultrasound imaging
    Imaging Research Laboratories, J. P. Robarts Research Institute, London, Ont., Canada
    不详
    不详
    不详
    [J]. Ultrasound Med. Biol., 5 (673-681):
  • [5] Intra- and Inter-observer Variability of Computed Tomographic Measurements of the Prostate Gland in Neutered Dogs
    Delaude, Alessandro
    Broeckx, Bart J. G.
    Saunders, Jimmy H.
    De Winter, Lauren
    Hillaert, Amber
    Stock, Emmelie
    [J]. FRONTIERS IN VETERINARY SCIENCE, 2021, 8
  • [6] Intra- and inter-observer variability in retinal thickness measurements using OCT 4
    Tannen, L
    Forfonova, T
    Lazar, M
    Malpica, B
    Thakkar, R
    Bhagat, N
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [7] Accuracy of prostate volume measurements in vitro using three-dimensional ultrasound
    Elliot, TL
    Downey, DB
    Tong, SD
    McLean, CA
    Fenster, A
    [J]. ACADEMIC RADIOLOGY, 1996, 3 (05) : 401 - 406
  • [8] Intra- And Inter-observer Variability Of A Retrospective Analysis Of Achilles Tendon Ultrasound Scans
    Wochatz, Monique
    Cassel, Michael
    Koenig, Niklas
    Froehlich, Katja
    Mayer, Frank
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 239 - 239
  • [9] Intra- and inter-observer reliability of perineal body volume measurements with 3-dimensional transperineal ultrasound
    Rahim, A.
    Ahmad, A.
    Tailor, V
    El Shamy, T.
    Bhide, A.
    Digesu, A.
    Fernando, R.
    Khullar, V
    [J]. INTERNATIONAL UROGYNECOLOGY JOURNAL, 2020, 31 (SUPPL 1) : S103 - S103
  • [10] Inter-observer variability in post-plan seed localization after permanent prostate brachytherapy: a multicentric study
    Orlandini, LC
    Lappi, S
    Mangili, P
    Ziglio, F
    Stea, L
    Giglioli, F
    Calamia, E
    Mascia, MP
    Longobardi, B
    Cattani, F