Evaluation of chemiluminescence reagents for selective detection of reactive oxygen species

被引:74
|
作者
Yamaguchi, Shinya
Kishikawa, Naoya
Ohyama, Kaname
Ohba, Yoshihito [2 ]
Kohno, Maiko [3 ]
Masuda, Toshinobu [3 ]
Takadate, Akira [3 ]
Nakashima, Kenichiro
Kuroda, Naotaka [1 ]
机构
[1] Nagasaki Univ, Grad Sch Biomed Sci, Course Pharmaceut Sci, Nagasaki 8528521, Japan
[2] Nagasaki Int Univ, Fac Pharmaceut Sci, Nagasaki 8593298, Japan
[3] Daiichi Coll Pharmaceut Sci, Minami Ku, Fukuoka 8158511, Japan
关键词
Reactive oxygen species; Chemiluminescent probe; Screening; Acridinium ester; Superoxide dismutase; LUMINOL-DEPENDENT CHEMILUMINESCENCE; MCLA CHEMILUMINESCENCE; FLUORESCENCE PROBES; HYDROGEN-PEROXIDE; SINGLET OXYGEN; SUPEROXIDE; DERIVATIVES; GENERATION; ANALOGS; DAMAGE;
D O I
10.1016/j.aca.2010.03.025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In order to evaluate the chemiluminescence (CL) reagents for selective detection of reactive oxygen species (ROS), we comprehensively measured the CL responses of 20 CL reagents (three luminol derivatives, two imidazopyrazinone derivatives, eight lophine derivatives, six acridinium ester derivatives andlucigenin) against six types of ROS (superoxide anion: O-2(center dot-), hydroxyl radical: (OH)-O-center dot, hydrogen peroxide: H2O2, hypochlorite anion: ClO-, singlet oxygen: O-1(2), and nitric oxide: NO). As a result of the screening, it was found that nine CL reagents selectively detected O-2(center dot-) while one CL reagent selectively detected (OH)-O-center dot. However, no CL reagent had selectivity on the detection of H2O2, ClO-, O-1(2) and NO. Our screening results could help to select the most suitable CL reagent for selective determination of different ROS. As an application study, 4-methoxyphenyl-10-methylacridinium-9-carboxylate (MMAC), one of the acridinium ester derivatives, showed high selectivity on the detection of O-2(center dot-), and thus was applied to the assay of superoxide dismutase (SOD) activity. The dynamic range and detection limit of the developed CL assay were 0.1-10 and 0.06 U mL(-1), respectively. Significant correlation (r = 0.997) was observed between the results by the CL assay using MMAC and the spectrophotometric assay using 2-(4-iodophenyl)-3-(4-nitrophenyl)-5-(2,4-disulfophenyl)-2H-tetrazolium monosodium salt. Crown Copyright (C) 2010 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:74 / 78
页数:5
相关论文
共 50 条
  • [31] Reactive oxygen species generation in human sperm: Luminol and lucigenin chemiluminescence probes
    McKinney, KA
    Lewis, SEM
    Thompson, W
    ARCHIVES OF ANDROLOGY, 1996, 36 (02): : 119 - 125
  • [32] Reference values of reactive oxygen species in seminal ejaculates using chemiluminescence assay
    Agarwal, Ashok
    Ahmad, Gulfam
    Sharma, Rakesh
    JOURNAL OF ASSISTED REPRODUCTION AND GENETICS, 2015, 32 (12) : 1721 - 1729
  • [33] Real-time detection of reactive oxygen species generation by marine phytoplankton using flow injection-chemiluminescence
    Milne, Angela
    Davey, Margaret S.
    Worsfold, Paul J.
    Achterberg, Eric P.
    Taylor, Alison R.
    LIMNOLOGY AND OCEANOGRAPHY-METHODS, 2009, 7 : 706 - 715
  • [34] Study of the electrochemically generated chemiluminescence of reactive oxygen species on indium tin oxide glass
    Zhao, Jinjin
    Guo, Wenying
    Li, Jingjing
    Chu, Haihong
    Tu, Yifeng
    ELECTROCHIMICA ACTA, 2012, 61 : 118 - 123
  • [35] Chemiluminescence assay of mucosal reactive oxygen species in gastric cancer, ulcer and antral mucosa
    Peng, Yen-Chun
    Hsu, Chia-Lang
    Tung, Chun-Fang
    Chou, Wai-Keung
    Huang, Lan-Ru
    Hung, Dong-Zong
    Hu, Wei-Hsiung
    Yang, Dar-Yu
    HEPATO-GASTROENTEROLOGY, 2008, 55 (82-83) : 770 - 773
  • [36] Quality control of reactive oxygen species measurement by luminol-dependent chemiluminescence assay
    Kobayashi, H
    Gil-Guzman, E
    Mahran, AM
    Sharma, RK
    Nelson, DR
    Thomas, AJ
    Agarwal, A
    JOURNAL OF ANDROLOGY, 2001, 22 (04): : 568 - 574
  • [37] Flow injection analysis for monitoring antioxidant effects on luminol chemiluminescence of reactive oxygen species
    Sariahmetoglu, M
    Wheatley, RA
    Çakici, I
    Kanzik, I
    Townshend, A
    ANALYTICAL LETTERS, 2003, 36 (04) : 749 - 765
  • [38] LUCIGENIN CHEMILUMINESCENCE AS A PROBE FOR MEASURING REACTIVE OXYGEN SPECIES PRODUCTION IN ESCHERICHIA-COLI
    PETERS, TR
    TOSK, JM
    GOULBOURNE, EA
    ANALYTICAL BIOCHEMISTRY, 1990, 186 (02) : 316 - 319
  • [39] Simultaneous use of electrochemistry and chemiluminescence to detect reactive oxygen species produced by human neutrophils
    Shleev, Sergey
    Wetteroe, Jonas
    Magnusson, Karl-Eric
    Ruzgas, Tautgirdas
    CELL BIOLOGY INTERNATIONAL, 2008, 32 (12) : 1486 - 1496
  • [40] Comparison of chemiluminescence and flow cytometry in the estimation of reactive oxygen and nitrogen species in human semen
    Aziz, Nabil
    Novotny, Jiri
    Oborna, Ivana
    Fingerova, Helena
    Brezinova, Jana
    Svobodova, Magda
    FERTILITY AND STERILITY, 2010, 94 (07) : 2604 - 2608