Point-of-Use Measurement of Salivary Cortisol levels

被引:0
|
作者
Yamaguchi, Masaki [1 ]
Yoshikawa, Suguru [1 ]
Tahara, Yusuke [1 ]
Niwa, Daisuke [2 ]
Imai, Yoshikatsu [2 ]
Shetty, Vivek [3 ]
机构
[1] Iwate Univ, Grad Sch Engn, 4-3-5 Ueda, Morioka, Iwate 0208551, Japan
[2] Nano Bion R&D Ctr Rohm Co Ltd, Kyoto, Japan
[3] Univ Calif Los Angeles, Sch Dent, Los Angeles, CA 90024 USA
基金
日本科学技术振兴机构;
关键词
DIAGNOSTICS;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The objective is to develop a novel methodology to analyze cortisol levels in saliva as an index of neuroendocrine response. In order to realize a portable, rapid and hand held biosensor of cortisol, we proposed an immuno-chromatographic test-strip based biosensor consisting of a disposable test-strip and a monitor. A fabricated disposable type test-strip has a size of 5 x 1.5 x 50 mm(3). In order to realize an immuno-chromatographic test-strip, a glucose oxidase (GOD) -cortisol conjugate was newly synthesized, because the speed and selectivity of immunological reactions is particularly attractive as a strategy for molecular recognition of cortisol. The synthesized molecule was identified as the GOD-cortisol conjugate by both its molecular weight and specific detection of cortisol. Three min after addition of GOD enzyme assay solution, a color change reaction at a test line was observed. The R-2 value for the calibration curve of the cortisol test strip was 0.95, and the relationship between its reflectance, r, and the cortisol level was r = 0.629 (1-0.232e ((-1.78 x cortisol))). The fabricated cortisol biosensor enabled us to analyze cortisol concentrations between 1 - 10 ng/ml within 25 min of dropping a cortisol solution on the test strip. Thus, it is suggested that the cortisol biosensor may possibly be used for point-of-use measurements in hospitals.
引用
收藏
页码:346 / 346
页数:1
相关论文
共 50 条
  • [1] MEASUREMENT OF SALIVARY CORTISOL LEVELS IN CRITICALLY ILL PATIENTS
    Lee, Jinwoo
    Lee, Sang-Min
    CRITICAL CARE MEDICINE, 2016, 44 (12)
  • [2] Is the Correlation between Salivary Cortisol and Serum Cortisol Reliable Enough to Enable Use of Salivary Cortisol Levels in Preterm Infants?
    Amin, Harish
    Wynne-Edwards, Katherine
    Amin, Parthiv
    Zhou, Ruokun
    Sundaram, Arun
    Martinez-Soto, Tania
    Pacaud, Daniele
    AMERICAN JOURNAL OF PERINATOLOGY, 2017, 34 (13) : 1302 - 1305
  • [3] The Effects of Mouthpiece Use on Salivary Cortisol Levels During Exercise
    Garner, Dena P.
    McDivitt, Erica
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2008, 40 (05): : S468 - S468
  • [4] Generation at point-of-use of BHF
    Verhaverbeke, S
    Liu, L
    SOLID STATE PHENOMENA, 1999, 65-6 : 267 - 270
  • [5] Point-of-use/entry treatment
    Water Services, 1995, 99 (1188):
  • [6] Automated measurement of salivary cortisol
    van Aken, MO
    Romijn, JA
    Miltenburg, JA
    Lentjes, EGWM
    CLINICAL CHEMISTRY, 2003, 49 (08) : 1408 - 1409
  • [7] Point-of-use purification for ultrapure water
    不详
    FILTRATION + SEPARATION, 2007, 44 (09) : 11 - 11
  • [8] Point-of-use silicon sources for CVD
    Saulys, DA
    Safvi, SA
    Pauly, N
    Dopke, JA
    Preston, BR
    GAines, DF
    Kuech, TF
    ENVIRONMENTAL, SAFETY, AND HEALTH ISSUES IN IC PRODUCTION, 1997, 447 : 139 - 143
  • [9] Making sense of point-of-use cleaning
    Meyer, Julie
    Sonstelie, Alison
    Biomedical Instrumentation and Technology, 2019, 53 (Horizon): : 56 - 60
  • [10] EFFICIENCY OF POINT-OF-USE TREATMENT DEVICES
    REGUNATHAN, P
    BEAUMAN, WH
    KREUSCH, EG
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 1983, 75 (01): : 42 - 50