Extended Motor Evoked Potentials Monitoring Helps Prevent Delayed Paraplegia After Aortic Surgery

被引:9
|
作者
See, Reiner B. [1 ]
Awosika, Oluwole O. [1 ,2 ]
Cambria, Richard P. [3 ]
Conrad, Mark F. [3 ]
Lancaster, Robert T. [3 ]
Patel, Virendra I. [3 ]
Chitilian, Hovig V. [4 ]
Kumar, Sandeep [5 ]
Simon, Mirela V. [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Neurol, WACC 739G,55 Fruit St, Boston, MA 02114 USA
[2] NINDS, NIH, Bldg 36,Rm 4D04, Bethesda, MD 20892 USA
[3] Massachusetts Gen Hosp, Dept Vasc Surg, Boston, MA 02114 USA
[4] Massachusetts Gen Hosp, Dept Anesthesia, Boston, MA 02114 USA
[5] Beth Israel Deaconess Med Ctr, Dept Neurol, Boston, MA 02215 USA
关键词
THORACOABDOMINAL ANEURYSM REPAIR; CEREBROSPINAL-FLUID DRAINAGE; COLLATERAL NETWORK CONCEPT; NEUROLOGIC DEFICIT; RISK; PERFUSION; PROTECTION; MANAGEMENT; ISCHEMIA; RECOVERY;
D O I
10.1002/ana.24610
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
ObjectiveMotor evoked potentials (MEPs) monitoring can promptly detect spinal cord ischemia (SCI) from aortic clamping during open thoracoabdominal aneurysm repair (OTAAR) with distal aortic perfusion (DAP) and thus help decrease the risk of immediate postoperative SCI (IP-SCI). However, neither stable MEPs during aortic clamp interval (ACI) nor absence of IP-SCI eliminate the possibility of delayed postoperative SCI (DP-SCI). We hypothesized that extension of MEPs monitoring beyond ACI can also help decrease the risk of DP-SCI. MethodsWe identified 150 consecutive patients at our institution between April 2005 and October 2014 who underwent OTAAR with DAP and MEPs monitoring and had no IP-SCI. Using logistic regression analysis, we studied the independent effect of extended MEPs monitoring on the risk of developing DP-SCI. We used a propensity score analysis to adjust for potential confounders, such as poorly controlled hypertension, previous aneurysm surgery, splenectomy, acute aortic dissection, aneurysm type, older age, and history of diabetes and smoking. ResultsFrom the 150 patients, 129 (86%) remained neurologically intact whereas 21 (14%) developed DP-SCI. Nineteen of these twenty-one patients (90%) had no extended monitoring. Fifty-seven of fifty-nine (97%) patients who benefited from extended monitoring had no DP-SCI (p = 0.003). Extended MEPs monitoring was independently associated with decreased risk of DP-SCI (odds ratio = 0.14; 95% confidence interval: 0.03, 0.65; p = 0.01). InterpretationMEPs detect the lowest systemic blood pressure that ensures appropriate spinal cord perfusion in the postoperative period. Thus, they inform the hemodynamic management of patients post-OTAAR, particularly in the absence of a reliable neurological exam. Ann Neurol 2016;79:636-645
引用
收藏
页码:636 / 645
页数:10
相关论文
共 50 条
  • [31] Improvement of motor evoked potentials monitoring is required during thoracic or thoracoabdominal aortic aneurysm surgery under hypothermic cardiopulmonary bypass
    Masahiko Kawaguchi
    Mikito Kawamata
    Yoshitsugu Yamada
    Journal of Anesthesia, 2012, 26 : 157 - 159
  • [32] Improvement of motor evoked potentials monitoring is required during thoracic or thoracoabdominal aortic aneurysm surgery under hypothermic cardiopulmonary bypass
    Kawaguchi, Masahiko
    Kawamata, Mikito
    Yamada, Yoshitsugu
    JOURNAL OF ANESTHESIA, 2012, 26 (02) : 157 - 159
  • [33] Evaluation of motor- and sensory-evoked potentials for spinal cord monitoring during thoracoabdominal aortic aneurysm surgery.
    Sueda T.
    Okada K.
    Watari M.
    Orihashi K.
    Shikata H.
    Matsuura Y.
    The Japanese Journal of Thoracic and Cardiovascular Surgery, 2000, 48 (1): : 60 - 65
  • [34] NONINVASIVE INTRAOPERATIVE MONITORING OF MOTOR EVOKED-POTENTIALS UNDER PROPOFOL ANESTHESIA - EFFECTS OF SPINAL SURGERY ON THE AMPLITUDE AND LATENCY OF MOTOR EVOKED-POTENTIALS
    JELLINEK, D
    JEWKES, D
    SYMON, L
    NEUROSURGERY, 1991, 29 (04) : 551 - 557
  • [35] CNS MONITORING BY MULTISPATIAL AND MULTIMODAL EVOKED-POTENTIALS DURING AORTIC-SURGERY
    SHIMOJI, K
    MARUYAMA, Y
    FUJIOKA, H
    SATOH, K
    ENDOH, H
    ANESTHESIOLOGY, 1986, 65 (3A) : A28 - A28
  • [36] Prolonged loss of leg myogenic motor evoked potentials during thoracoabdominal aortic aneurysm repair, without postoperative paraplegia
    Denda S.
    Taneoka M.
    Honda H.
    Watanabe Y.
    Imai H.
    Kitahara Y.
    Journal of Anesthesia, 2006, 20 (4) : 314 - 318
  • [37] Predictive Value and Safety of Intraoperative Neurophysiological Monitoring With Motor Evoked Potentials in Glioma Surgery
    Krieg, Sandro M.
    Shiban, Ehab
    Droese, Doris
    Gempt, Jens
    Buchmann, Niels
    Pape, Haiko
    Ryang, Yu-Mi
    Meyer, Bernhard
    Ringel, Florian
    NEUROSURGERY, 2012, 70 (05) : 1060 - 1070
  • [38] Intraoperative continuous monitoring of facial motor evoked potentials in acoustic neuroma surgery Comments
    Kohno, Michihiro
    Saito, Kiyoshi
    Meybodi, Ali Tayebi
    NEUROSURGICAL REVIEW, 2014, 37 (04) : 675 - 676
  • [39] PARAPLEGIA AFTER SURGERY FOR ABDOMINAL AORTIC ANEURYSMS
    TAYLOR, RL
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1975, 234 (13): : 1319 - 1319
  • [40] PARAPLEGIA AFTER SURGERY FOR ABDOMINAL AORTIC ANEURYSMS
    GOLDEN, GT
    WELLONS, HA
    MULLER, WH
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1975, 233 (07): : 768 - 769