The effect of ion implantation on the wear of Co-Cr-Mo alloy

被引:11
|
作者
Werner, Z. [1 ]
Barlak, M.
Gradzka-Dahlke, M.
Diduszko, R.
Szymczyk, W.
Dabrowski, J.
Piekoszewski, J.
Borkowska, K.
机构
[1] Andrzej Soltan Inst Nucl Studies, PL-05400 Otwock, Poland
[2] Bialystok Tech Univ, PL-15351 Bialystok, Poland
[3] Inst Chem Phys, PAS, PL-01224 Warsaw, Poland
[4] Ind Inst Elect, PL-01241 Warsaw, Poland
[5] Inst Elect Mat Technol, PL-01919 Warsaw, Poland
[6] Inst Nucl Chem & Technol, PL-03145 Warsaw, Poland
关键词
Co-Cr-Mo alloys; ion implantation; wear;
D O I
10.1016/j.vacuum.2007.01.014
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The effect of C+N and O ion implantation upon tribological properties of Co-Cr-Mo alloy was studied for fluence range 3-7 x 10(17)cm(-2) and implantation temperature range 200-400 degrees C. Phase structure changes and implanted ion distributions were determined. A marked improvement of the wear rate was noticed. Higher implantation temperatures reduce the improvement. No traces of nitride or carbide phases have been found but chromium oxide phase has been detected after O implantation. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1191 / 1194
页数:4
相关论文
共 50 条
  • [41] STATISTICAL TREATMENT OF FATIGUE OF CAST CO-CR-MO PROSTHESIS ALLOY
    MILLER, HL
    ROSTOKER, W
    GALANTE, JO
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1976, 10 (03): : 399 - 412
  • [42] MICROSTRUCTURAL CHANGES DURING ISOTHERMAL FORGING OF A CO-CR-MO ALLOY
    IMMARIGEON, JP
    RAJAN, K
    WALLACE, W
    METALLURGICAL TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 1984, 15 (02): : 339 - 345
  • [43] Interfacial reaction between Co-Cr-Mo alloy and liquid Al
    Tang, Ning
    Li, Yunping
    Koizumi, Yuichiro
    Kurosu, Shingo
    Chiba, Akihiko
    CORROSION SCIENCE, 2013, 75 : 262 - 268
  • [44] In vitro biocompatibility assessment of Co-Cr-Mo dental cast alloy
    Dimic, Ivana
    Cvijovic-Alagic, Ivana
    Obradovic, Natasa
    Petrovic, Jelena
    Putic, Slavisa
    Rakin, Marko
    Bugarski, Branko
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2015, 80 (12) : 1541 - 1552
  • [45] In vitro biocorrosion of Co-Cr-Mo implant alloy by macrophage cells
    Lin, HY
    Bumgardner, JD
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2004, 22 (06) : 1231 - 1236
  • [46] Friction-wear properties of nickel-free Co-Cr-Mo alloy in a simulated body fluid
    Maruyama, N
    Kawasaki, H
    Yamamoto, A
    Hiromoto, S
    Imai, H
    Hanawa, T
    MATERIALS TRANSACTIONS, 2005, 46 (07) : 1588 - 1592
  • [48] Athermal ε-martensite in a Co-Cr-Mo alloy:: grain size effects
    Huang, P
    López, HF
    MATERIALS LETTERS, 1999, 39 (04) : 249 - 253
  • [49] Surface modification of Co-Cr-Mo alloy by plasma assisted CVD
    Resen, Ali Mezher
    MATERIALS TODAY-PROCEEDINGS, 2021, 42 : 2896 - 2900
  • [50] Cytocompatibility for Co-Cr-Mo alloy with a small amount of zirconium or carbon
    Numata, Yasuko
    Syuto, Bunei
    Nomura, Naoyuki
    Chiba, Akihiko
    JOURNAL OF THE JAPAN INSTITUTE OF METALS, 2007, 71 (07) : 578 - 585