Non-invasive intravenous coronary angiography using electron beam tomography and multislice computed tomography

被引:72
|
作者
Leber, AW
Knez, A
Becker, C
Becker, A
White, C
Thilo, C
Reiser, M
Haberl, R
Steinbeck, G
机构
[1] Univ Munich, Klinikum Grosshadern, Med Klin 1, Dept Cardiol, D-81377 Munich, Germany
[2] Klinikum Grosshadern, Inst Diagnost Radiol, Munich, Germany
[3] Univ Minnesota, Div Cardiol, Minneapolis, MN 55455 USA
关键词
D O I
10.1136/heart.89.6.633
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Electron beam computed tomography (EBCT) and multislice computed tomography (MSCT) are both suitable for non-invasive identification of coronary stenoses. Objective: To compare intravenous coronary EBCT angiography (EBCTA) and MSCT angiography (MSCTA) with regard to image quality and diagnostic accuracy. Methods: EBCTA was done using an Imatron C-150 XP scanner in 101 patients following a standard protocol (slice thickness 3 mm, overlap 1 mm, acquisition time 100 ms, prospective ECG trigger). For MSCTA in a different set of 91 patients (using a Siemens Somatom Plus4VZ scanner), the whole volume of the heart was covered in a spiral technique by four simultaneous detector rows. Using retrospective ECG gating, the raw data were reconstructed in (mean (SD)) 215 (12) axial slices acquired in diastole (slice thickness 1.25 mm, overlap 0.5 mm, acquisition time 250 ms/slice). Results: With EBCTA, 76% of predetermined coronary segments in a nine segment model could be assessed with diagnostic image quality, and with MSCTA, 82%. A low contrast to noise ratio with EBCTA, and the presence of motion artefacts with MSCTA were the main reasons for inadequate image quality. Using conventional angiography as the gold standard, 77% of stenoses of > 50% could be identified correctly with EBCTA and 82% with MSCTA. Significant stenoses were correctly ruled out in 93% of segments with EBCTA, and in 96% of segments with MSCTA. The average contrast to noise ratio was higher with MSCTA than with EBCTA (9.4 v 6.5; p < 0.001). Conclusions: EBCTA and MSCTA show similarly high levels of accuracy for determining and ruling out significant coronary artery stenoses. MSCTA is capable of providing good image quality in more coronary segments than EBCTA because of its better contrast to noise ratio and higher spatial resolution. Motion artefacts seen at heart rates of > 75 beats/min and a higher radiation exposure are the main limitations of MSCTA.
引用
收藏
页码:633 / 639
页数:7
相关论文
共 50 条
  • [31] Noninvasive coronary angiography with multislice computed tomography
    Hoffmann, MHK
    Shi, HS
    Schmitz, BL
    Schmid, FT
    Lieberknecht, ML
    Schulze, R
    Ludwig, B
    Kroschel, U
    Jahnke, N
    Haerer, W
    Brambs, HJ
    Aschoff, AJ
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (20): : 2471 - 2478
  • [32] INVASIVE CORONARY ANGIOGRAPHIC AND REVASCULARIZATION RATES AFTER NON-INVASIVE COMPUTED TOMOGRAPHY CORONARY ANGIOGRAPHY
    de Graaf, Fleur Rianne
    Schuijf, Joanne D.
    de Boer, Stephanie M.
    van Werkhoven, Jacob M.
    van Velzen, Joella E.
    Kroft, Lucia J.
    de Roos, Albert
    Jukema, J. Wouter
    Schalij, Martin J.
    van der Wall, Ernst E.
    Bax, Jeroen J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E780 - E780
  • [33] Electron beam tomography: Non-invasive evaluation of coronary stents
    Haberl, R
    VonSmekal, A
    Knez, A
    Boekstegers, P
    Giehrl, W
    Reiser, M
    Steinbeck, G
    CIRCULATION, 1996, 94 (08) : 79 - 79
  • [34] Non-invasive imaging of vein grafts with multislice computed tomography
    Feuchtner, Gudrun M.
    EUROPEAN SURGERY-ACTA CHIRURGICA AUSTRIACA, 2007, 39 (02): : 105 - 110
  • [35] Is non-invasive multislice computer tomography coronary angiography a valid anternative to invasive coronary angiography in patients with suspected coronary artery disease?
    Kaiser, C
    Haller, S
    Brunner, HP
    Bremerich, J
    Bongartz, G
    Steinbrich, W
    Pfisterer, M
    Buser, R
    EUROPEAN HEART JOURNAL, 2004, 25 : 479 - 480
  • [36] Non-invasive coronary angiography by multislice detector computed tomography: Initial results df the new-age-study
    Schroeder, S
    Baumbach, A
    Kopp, AF
    Kuettner, A
    Georg, C
    Herdeg, C
    Oberhoff, M
    Claussen, CD
    Karsch, KR
    CIRCULATION, 2000, 102 (18) : 603 - 603
  • [37] Non-invasive physiological assessment of coronary artery obstruction on coronary computed tomography angiography
    Becker, Leonie M.
    Peper, Joyce
    van Nes, Sophie H.
    van Es, Hendrik W.
    Sjauw, Krischan D.
    van de Hoef, Tim P.
    Leiner, Tim
    Swaans, Martin J.
    NETHERLANDS HEART JOURNAL, 2024, 32 (11) : 397 - 404
  • [38] Image quality of noninvasive coronary angiography using multislice spiral computed tomography and electron-beam computed tomography -: Intraindividual comparison in an animal model
    Lembcke, A
    Wiese, TH
    Schnorr, J
    Wagner, S
    Mews, J
    Kroencke, TJ
    Enzweiler, CNH
    Hamm, B
    Taupitz, M
    INVESTIGATIVE RADIOLOGY, 2004, 39 (06) : 357 - 364
  • [39] Feasibility of intravenous administration of landiolol hydrochloride for Multislice Computed Tomography Coronary Angiography
    Isobe, S.
    Sato, K.
    Yoshikawa, D.
    Kobayashi, M.
    Meno, C.
    Kato, M.
    Ishii, H.
    Murohara, T.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2009, 11 (0B) : S1 - S1
  • [40] Noninvasive coronary artery angiography using electron beam computed tomography
    Rumberger, JA
    Rensing, BJ
    Reed, JE
    Ritman, EL
    Sheedy, PF
    MEDICAL IMAGING 1996: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 1996, 2709 : 93 - 106