3-D Phantom and In Vivo Cardiac Speckle Tracking Using a Matrix Array and Raw Echo Data

被引:17
|
作者
Byram, Brett C. [1 ]
Holley, Greg [2 ]
Giannantonio, Doug M. [1 ]
Trahey, Gregg E. [1 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27706 USA
[2] Ultrasound Business Unit, Siemens Healthcare Sector, Mountain View, CA USA
关键词
REGIONAL MYOCARDIAL-FUNCTION; BLOOD-FLOW; DELAY ESTIMATION; MOTION TRACKING; TISSUE MOTION; STRAIN-RATE; VELOCITY-MEASUREMENT; HEALTHY-VOLUNTEERS; CORONARY-ARTERIES; WALL-MOTION;
D O I
10.1109/TUFFC.2010.1489
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Cardiac motion has been tracked using various methods, which vary in their invasiveness and dimensionality. One such noninvasive modality for cardiac motion tracking is ultrasound. Three-dimensional ultrasound motion tracking has been demonstrated using detected data at low volume rates. However, the effects of volume rate, kernel size, and data type (raw and detected) have not been sufficiently explored. First comparisons are made within the stated variables for 3-D speckle tracking. Volumetric data were obtained in a raw, baseband format using a matrix array attached to a high parallel receive beam count scanner. The scanner was used to acquire phantom and human in vivo cardiac volumetric data at 1000-Hz volume rates. Motion was tracked using phase-sensitive normalized cross-correlation. Subsample estimation in the lateral and elevational dimensions used the grid-slopes algorithm. The effects of frame rate, kernel size, and data type on 3-D tracking are shown. In general, the results show improvement of motion estimates at volume rates up to 200 Hz, above which they become stable. However, peak and pixel hopping continue to decrease at volume rates higher than 200 Hz. The tracking method and data show, qualitatively, good temporal and spatial stability ( for independent kernels) at high volume rates.
引用
收藏
页码:839 / 854
页数:16
相关论文
共 50 条
  • [41] An Object-Tracking Algorithm for 3-D Range Data Using Motion and Surface Estimation
    Zeng, Shuqing
    IEEE TRANSACTIONS ON INTELLIGENT TRANSPORTATION SYSTEMS, 2013, 14 (03) : 1109 - 1118
  • [42] 3-D data merging using Holoimage
    Zhang, Song
    Yau, Shing-Tung
    TWO- AND THREE-DIMENSIONAL METHODS FOR INSPECTION AND METROLOGY V, 2007, 6762
  • [43] Quantitative 3-D diagnostic ultrasound imaging using a modified transducer array and an automated image tracking technique
    Hossack, JA
    Sumanaweera, TS
    Napel, S
    Ha, JS
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (08) : 1029 - 1038
  • [44] Multiple Wideband Acoustic Source Tracking in 3-D Space Using a Distributed Acoustic Vector Sensor Array
    Zhong, Xionghu
    Premkumar, A. B.
    Wang, Haiyan
    IEEE SENSORS JOURNAL, 2014, 14 (08) : 2502 - 2513
  • [45] A miniaturized catheter 2-D array for real-time, 3-D intracardiac echo cardiography
    Lee, W
    Idriss, SF
    Wolf, PD
    Smith, SW
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (10) : 1334 - 1346
  • [46] 3-D Ultrasound Imaging Using Helicoid Array Transducers
    Kim, Young-Joong
    Wolf, Patrick D.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (03) : 697 - 706
  • [47] ANNULAR ARRAY 3-D SAR: RESOLUTION ANALYSIS AND DATA PROCESSING
    Pu, Ling
    Zhang, Xiaoling
    Shi, Jun
    Wei, Shunjun
    IGARSS 2018 - 2018 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, 2018, : 565 - 568
  • [48] Portable 3-D modeling using visual pose tracking
    Strobl, Klaus H.
    Mair, Elmar
    Bodenmueller, Tim
    Kielhoefer, Simon
    Wuesthoff, Tilo
    Suppa, Michael
    COMPUTERS IN INDUSTRY, 2018, 99 : 53 - 68
  • [49] 3-D Gaze Tracking Using Pupil Contour Features
    Lai, Chih-Chuan
    Shih, Sheng-Wen
    Tsai, Hsin-Ruey
    Hung, Yi-Ping
    2014 22ND INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION (ICPR), 2014, : 1162 - 1166
  • [50] Robust 3-D landmark tracking using trinocular vision
    Mallon, J
    Ghita, O
    Whelan, PF
    OPTP-IRELAND 2002: OPTICAL METROLOGY, IMAGING, AND MACHINE VISION, 2003, 4877 : 221 - 229